{"id":1975,"date":"2026-07-30T11:24:08","date_gmt":"2026-07-30T03:24:08","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/wlm7dc-400a-2300-2p-3p-wlm7dc-series-photovoltaic-solar-type-molded-case-circuit-breakers-250vdc-500\/"},"modified":"2026-07-30T11:24:10","modified_gmt":"2026-07-30T03:24:10","slug":"wlm7dc-400a-2300-2p-3p-wlm7dc-series-photovoltaic-solar-type-molded-case-circuit-breakers-250vdc-500","status":"publish","type":"product","link":"https:\/\/w9-group.com\/ru\/product\/wlm7dc-400a-2300-2p-3p-wlm7dc-series-photovoltaic-solar-type-molded-case-circuit-breakers-250vdc-500\/","title":{"rendered":"WLM7DC-400A-2300 2P\/3P WLM7DC Series Photovoltaic solar type Molded Case Circuit Breakers 250vdc\/500vdc\/750VDC\/1000VDC\/1500VDC 400A Photovoltaic DC circuit breaker"},"content":{"rendered":"<h2>\nMCCB\u00a0Highlights<br \/>\n<\/h2>\n<p>WLM7DC series Moulded Case Circuit Breaker is designed to distribute power and protect the circuit and power equipment against overload in solar system.<br \/>\nIs a new type of product, developed and manufactured by Adopting international advanced technology<br \/>\nIt is supplied with rated insulation voltage 1000V and used for circuit of\u00a0 50Hz \/60Hz, rated operation voltage DC 1000V or below rated operation current up to 800A for infrequent changing over and starting of the motors. Equipped with the protection devices for over-current, short circuit and under voltage, the product is capable of preventing damage of circuits and supply units. The product conforms to IEC60947-2 standard.<\/p>\n<h2>\nMain performance index of WLM7DC\u00a0 series circuit breaker<br \/>\n<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"10\">\nWLM7DC Moulded Case Circuit Breaker<\/td>\n<td colspan=\"3\">400<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated operating current In (A),40\u2103<\/td>\n<td colspan=\"4\">250-315-350-400<\/td>\n<\/tr>\n<tr><\/tr>\n<tr>\n<td colspan=\"10\">Rated insulation voltage Ui (V)<\/td>\n<td colspan=\"3\">1500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated impulse withstand voltage (kV)<\/td>\n<td colspan=\"3\">12<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated operational voltage Ue(V),AC 50\/60Hz<\/td>\n<td colspan=\"3\">110\/250\/500\/750\/1000\/1200\/1500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Breaking capacity code<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">M<\/td>\n<td colspan=\"1\">H<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"4\">Number of poles<\/td>\n<td colspan=\"5\">\n2P<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">3P<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DC250V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">25<\/td>\n<td colspan=\"1\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DC500V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">25<\/td>\n<td colspan=\"1\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"4\">\nRated ultimate<br \/>\nshort-circuit breaking<br \/>\ncapacity Icu(kA)\n<\/td>\n<td colspan=\"5\">DC750V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">15<\/td>\n<td colspan=\"1\">25<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DC1000V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">15(3P30)<\/td>\n<td colspan=\"1\">25(3P40)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DC1250V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DC1500V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">10(3P25)<\/td>\n<td colspan=\"1\">10(3P30)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"6\">\nRated service breaking<br \/>\ncapacity Ics(kA)\n<\/td>\n<td colspan=\"5\">DC250V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">25<\/td>\n<td colspan=\"1\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DC500V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">25<\/td>\n<td colspan=\"1\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DC750V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">15<\/td>\n<td colspan=\"1\">25<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DC1000V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">15(3P30)<\/td>\n<td colspan=\"1\">25(3P40)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DC1250V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DC1500V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">10(3P20)<\/td>\n<td colspan=\"1\">10(3P30)<\/td>\n<\/tr>\n<tr><\/tr>\n<tr>\n<td colspan=\"10\">Standard<\/td>\n<td colspan=\"3\">\nIEC\/EN 60947-2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Utilization category<\/td>\n<td colspan=\"3\">A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Ambient temperature<\/td>\n<td colspan=\"3\">\n-40\u2103 ~+70 \u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Safety of insulation<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Arcing distance<\/td>\n<td colspan=\"3\">0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\nMechanical life<br \/>\n(CO recycle)\n<\/td>\n<td colspan=\"5\">Maintenance free<\/td>\n<td colspan=\"3\">20000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"1\">\nElectrical life<br \/>\n(CO recycle)\n<\/td>\n<td colspan=\"5\">Maintenance free<\/td>\n<td colspan=\"3\">2000(DC1500V is :1000times)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Release units<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Distribution protection<\/td>\n<td colspan=\"5\">TM<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Mounting and connection<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Fixed<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Plug-in<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Draw-out\n<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DIN rail<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Dimension<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">\nDimension (mm)<br \/>\nW\u00d7H\u00d7D\n<\/td>\n<td colspan=\"5\">Width<\/td>\n<td colspan=\"3\">130\/182<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Height<\/td>\n<td colspan=\"3\">270<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Depth<\/td>\n<td colspan=\"3\">125.8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Weight<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">Weight(kg)\/Fixed<\/td>\n<td colspan=\"5\">2P<\/td>\n<td colspan=\"3\">2.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">3P<\/td>\n<td colspan=\"3\">3.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">4P<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\nOverall and installation dimensions of circuit breaker<br \/>\n<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/wlm7dc-400a-2300-2p-3p-wlm7dc-series-photovoltaic-solar-type-molded-case-detail-01.webp\" alt=\"WLM7DC-400A-2300 2P\/3P WLM7DC Series Photovoltaic solar type Molded Case Circuit Breakers 250vdc\/500vdc\/750VDC\/1000VDC\/1500VDC 400A Photovoltaic DC circuit breaker detail image 1\" loading=\"lazy\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Rated Current : 400A Number Of Poles : 2P\/3P Rated Working Voltage : 800V<\/p>","protected":false},"featured_media":1976,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[99,105,179],"product_tag":[],"class_list":["post-1975","product","type-product","status-publish","has-post-thumbnail","product_cat-dc-mccb","product_cat-wlm7dc","product_cat-wlm7dc-all-product","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product\/1975","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/comments?post=1975"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/media\/1976"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/media?parent=1975"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product_brand?post=1975"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product_cat?post=1975"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product_tag?post=1975"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}