{"id":1666,"date":"2026-07-30T11:27:41","date_gmt":"2026-07-30T03:27:41","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/jcsd-60-surge-protection-device-30-60ka-surge-arrestor\/"},"modified":"2026-07-30T11:27:41","modified_gmt":"2026-07-30T03:27:41","slug":"jcsd-60-surge-protection-device-30-60ka-surge-arrestor","status":"publish","type":"product","link":"https:\/\/w9-group.com\/ru\/product\/jcsd-60-surge-protection-device-30-60ka-surge-arrestor\/","title":{"rendered":"AC Surge Protective Device JCSD-60 Surge protection Device 30\/60kA Surge Arrestor"},"content":{"rendered":"<h2>\nIntroduction<br \/>\n<\/h2>\n<p>JCSD-60 Surge protection devices are designed to absorb and dissipate the excess electrical energy caused by power surges, ensuring that the equipment connected to the system is not damaged. JCSD-60 SPDs can help prevent costly equipment downtime, repairs, and replacements.<\/p>\n<p>JCSD-60 surge arrestors are designed to absorb and dissipate the excess electrical energy caused by power surges, ensuring that the equipment connected to the system is not damaged. This SPDs can help prevent costly equipment downtime, repairs, and replacements. The devices are also designed to be easy to install and maintain.<\/p>\n<p>JCSD-60 Spds is characterized by its capacity to safely discharge current with 8\/20 \u00b5s wave form. T2 and T2+3 SPDs are available in specific multi-pole versions for all distribution systems.<\/p>\n<p>Our JCSD-60 surge protection device is built with the latest technology and a sleek, modern design that will blend seamlessly with any electrical system. It is DIN-rail mountable, making it easy to install and use in a variety of settings.<\/p>\n<p>One of the most critical features of our surge protection device is its nominal discharge current In 30kA (8\/20 \u00b5s) per path. This means that it can withstand high levels of electrical surges without causing any harm to your equipment. Furthermore, its maximum discharge current Imax 60kA (8\/20 \u00b5s) makes it a powerful tool in preventing damage caused by surges.<\/p>\n<p>Our JCSD-60 Surge protection device is ergonomically designed to ensure maximum protection for all of your electronics. It is crafted from high-quality materials and carefully tested to ensure that it can withstand any power surge.<\/p>\n<h2>\nProduct Description<br \/>\n<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcsd-60-surge-protection-device-30-60ka-surge-arrestor-detail-01.webp\" alt=\"AC Surge Protective Device JCSD-60 Surge protection Device 30\/60kA Surge Arrestor detail image 1\" loading=\"lazy\"><\/p>\n<ul>\n<li>Main Features<\/li>\n<li>Available in 1 Pole ,2P+N ,3 Pole,4 Pole, 3P+N<\/li>\n<li>MOV or MOV+GSG Technology<\/li>\n<li>Nominal discharge current In 30kA (8\/20 \u00b5s) per path<\/li>\n<li>Maximum discharge current Imax 60kA (8\/20 \u00b5s)<\/li>\n<li>Plug-in module design with status indication<\/li>\n<li>Visual Indication: Green=OK, Red=Replace<\/li>\n<li>Optional Remote indication contact<\/li>\n<li>Din Rail Mounted<\/li>\n<li>Pluggable replacement modules<\/li>\n<li>Suitable for TN, TNC-S, TNC and TT systems<\/li>\n<li>Complies with IEC61643-11 &amp; EN 61643-11<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcsd-60-surge-protection-device-30-60ka-surge-arrestor-detail-02.webp\" alt=\"AC Surge Protective Device JCSD-60 Surge protection Device 30\/60kA Surge Arrestor detail image 2\" loading=\"lazy\"><\/p>\n<ul>\n<li>Technical Data<\/li>\n<li>Type 2<\/li>\n<li>Network, 230 V single-phase, 400 V 3-phase<\/li>\n<li>Max. AC operating voltage Uc: 275V<\/li>\n<li>Temporary Over Voltage (TOV) Charasteristics &#8211; 5 sec. UT: 335 Vac withstand<\/li>\n<li>Temporary Over Voltage (TOV) Charasteristics &#8211; 120 mn UT: 440 Vac disconnection<\/li>\n<li>Nominal discharge current In\uff1a 30 kA<\/li>\n<li>Max. discharge current Imax\uff1a60kA<\/li>\n<li>Total Maximum discharge current Imax total\uff1a80kA<\/li>\n<li>Withstand on Combination waveform IEC 61643-11 Uoc\uff1a6kV<\/li>\n<li>Protection level Up\uff1a1.8kV<\/li>\n<li>Protection level N\/PE at 5 kA \uff1a0.7 kV<\/li>\n<li>Residual voltage L\/PE at 5 kA\uff1a0.7 kV<\/li>\n<li>Admissible short-circuit current\uff1a25kA<\/li>\n<li>Connection to Network\uff1aBy screw terminals: 2.5-25 mm\u00b2<\/li>\n<li>Mounting\uff1aSymmetrical rail 35 mm (DIN 60715)<\/li>\n<li>Operating temperature\uff1a-40 \/ +85\u00b0C<\/li>\n<li>Protection rating\uff1aIP20<\/li>\n<li>Failsafe mode\uff1a Disconnection from AC network<\/li>\n<li>Disconnection indicator\uff1a1 mechanical indicator by pole &#8211; Red\/Green<\/li>\n<li>Fuses\uff1a50 A mini. &#8211; 125 A max. &#8211; Fuses Type gG<\/li>\n<li>Standards compliance\uff1aIEC 61643-11 \/ EN 61643-11<\/li>\n<\/ul>\n<table>\n<tbody>\n<tr>\n<td>Technology<\/td>\n<td>MOV, MOV+GSG are available<\/td>\n<\/tr>\n<tr>\n<td>Type<\/td>\n<td>Type2<\/td>\n<\/tr>\n<tr>\n<td>Network<\/td>\n<td>230 V single-phase<br \/>\n400 V 3-phase<\/td>\n<\/tr>\n<tr>\n<td>Max. AC operating voltage\u00a0\u00a0 Uc<\/td>\n<td>275V<\/td>\n<\/tr>\n<tr>\n<td>Temporary Over Voltage (TOV) Charasteristics &#8211; 5 sec.\u00a0\u00a0 UT<\/td>\n<td>335 Vac withstand<\/td>\n<\/tr>\n<tr>\n<td>Temporary Over Voltage (TOV) Charasteristics &#8211; 120 mn\u00a0\u00a0 UT<\/td>\n<td>440 Vac disconnection<\/td>\n<\/tr>\n<tr>\n<td>Nominal discharge current\u00a0\u00a0\u00a0 In<\/td>\n<td>30 kA<\/td>\n<\/tr>\n<tr>\n<td>Max. discharge current\u00a0 Imax<\/td>\n<td>60kA<\/td>\n<\/tr>\n<tr>\n<td>Withstand on Combination waveform IEC 61643-11\u00a0 Uoc<\/td>\n<td>6kV<\/td>\n<\/tr>\n<tr>\n<td>Protection level\u00a0 Up<\/td>\n<td>1.8kV<\/td>\n<\/tr>\n<tr>\n<td>Protection level N\/PE at 5 kA<\/td>\n<td>0.7 kV<\/td>\n<\/tr>\n<tr>\n<td>Residual voltage L\/PE at 5 kA<\/td>\n<td>0.7 kV<\/td>\n<\/tr>\n<tr>\n<td>Admissible short-circuit current<\/td>\n<td>25kA<\/td>\n<\/tr>\n<tr>\n<td>Connection to Network<\/td>\n<td>By screw terminals: 2.5-25 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td>Mounting<\/td>\n<td>Symmetrical rail 35 mm (DIN 60715)<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>-40 \/ +85\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Protection rating<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Failsafe mode<\/td>\n<td>\u00a0Disconnection from AC network<\/td>\n<\/tr>\n<tr>\n<td>Disconnection indicator<\/td>\n<td>1 mechanical indicator by pole &#8211; Red\/Green<\/td>\n<\/tr>\n<tr>\n<td>Fuses<\/td>\n<td>50 A mini. &#8211; 125 A max. &#8211; Fuses Type gG<\/td>\n<\/tr>\n<tr>\n<td>Standards compliance<\/td>\n<td>IEC 61643-11 \/ EN 61643-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcsd-60-surge-protection-device-30-60ka-surge-arrestor-detail-03.webp\" alt=\"AC Surge Protective Device JCSD-60 Surge protection Device 30\/60kA Surge Arrestor detail image 3\" loading=\"lazy\"><\/p>\n<p>Type 1<br \/>\nSPD which can discharge partial lightning current<br \/>\nwith a typical waveform 10\/350 \u03bcs (Class I test). Usually employs spark gap technology.<br \/>Type 2<br \/>\nSPD which can prevent the spread of overvoltages in the electrical installations and protects equipment connected to it. It usually employs metal oxide varistor (MOV) technology and is characterised by an 8\/20 \u03bcs current wave (Class II test)<\/p>\n<p>Type &#8211; Surge protection devices are classified into types according to their discharge capacity. The term Class is also commonly used.<\/p>\n<p>Iimp &#8211; Impulse current of 10\/350 \u03bcs waveform<br \/>\nassociated with Type 1 SPD\u2019s<\/p>\n<p>In &#8211; Surge current of 8\/20 \u03bcs waveform<br \/>\nassociated with Type 2 SPD\u2019s<\/p>\n<p>Up &#8211; The residual voltage that is measured across<br \/>\nthe terminal of the SPD when In is applied<\/p>\n<p>Uc &#8211; The maximum voltage which may be<br \/>\ncontinuously applied to the SPD without it conducting.<\/p>","protected":false},"excerpt":{"rendered":"<p>Surge protection devices (SPDs) are essential components of any electrical system that help protect equipment from damaging voltage surges caused by lightning strikes, power outages, or other electrical disturbances. JCSD-60 SPDs are designed to divert excess electrical current away from sensitive equipment, reducing the risk of damage or failure.<\/p>","protected":false},"featured_media":1667,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[73],"product_tag":[],"class_list":["post-1666","product","type-product","status-publish","has-post-thumbnail","product_cat-ac-surge-protective-device","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product\/1666","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/comments?post=1666"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/media\/1667"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/media?parent=1666"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product_brand?post=1666"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product_cat?post=1666"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product_tag?post=1666"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}