{"id":3409,"date":"2026-03-24T09:00:00","date_gmt":"2026-03-24T01:00:00","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/blog\/advanced-protection-of-800v-mccb-electronic-jcr3hm-rcd-with-built-in-lsig-trip-unit\/"},"modified":"2026-10-20T10:37:31","modified_gmt":"2026-10-20T02:37:31","slug":"%d0%bf%d0%b5%d1%80%d0%b5%d0%b4%d0%be%d0%b2%d0%b0%d1%8f-%d0%b7%d0%b0%d1%89%d0%b8%d1%82%d0%b0-%d1%8d%d0%bb%d0%b5%d0%ba%d1%82%d1%80%d0%be%d0%bd%d0%bd%d0%be%d0%b3%d0%be-%d0%ba%d0%be%d0%bc%d0%bc%d1%83","status":"publish","type":"post","link":"https:\/\/w9-group.com\/ru\/blog\/advanced-protection-of-800v-mccb-electronic-jcr3hm-rcd-with-built-in-lsig-trip-unit\/","title":{"rendered":"JCR3HM RCCB vs LSIG MCCB: \u0444\u0443\u043d\u043a\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u0438 \u043f\u0440\u0435\u0434\u0435\u043b\u044c\u043d\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438"},"content":{"rendered":"<p>The older title combines two different device descriptions: an 800 V electronic MCCB with LSIG and the JCR3HM RCD. They must not be treated as one product. The current JCR3HM listing identifies an <a href=\"https:\/\/w9-group.com\/ru\/%d0%bf%d1%80%d0%be%d0%b4%d1%83%d0%ba%d1%82%d1%8b-%d0%b4%d0%bb%d1%8f-%d0%b7%d0%b0%d1%89%d0%b8%d1%82%d1%8b-%d1%86%d0%b5%d0%bf%d0%b5%d0%b9\/rccb-circuit-protection-products\/\">RCCB<\/a> for residual-current protection, with separate coordinated overcurrent protection required.<\/p>\n<p>The <strong>JCR3HM RCCB<\/strong> table lists 2P\/4P, Type A or AC, 30\/100\/300 mA options and current choices from 25 to 100 A. It lists 230\/240 V for 2P and 400\/415 V for 4P. It does not establish an 800 V LSIG MCCB rating.<\/p>\n<h2>What JCR3HM does<\/h2>\n<p>It detects residual current within the selected waveform and sensitivity scope. An RCCB under IEC 61008-1 has no <strong>integral overcurrent protection<\/strong>. Its current-carrying rating must therefore be coordinated with the circuit&#8217;s MCB or fuse and the manufacturer&#8217;s fault-protection arrangement.<\/p>\n<p>Choose waveform type from the connected load and sensitivity from the protection objective and installation rules. A 300 mA setting cannot simply replace required 30 mA additional protection to avoid trips.<\/p>\n<p>\u0420\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0438\u0442\u0435 \u0440\u0430\u0437\u043d\u0438\u0446\u0443 \u043c\u0435\u0436\u0434\u0443 <a href=\"https:\/\/w9-group.com\/ru\/blog\/what-is-the-difference-between-rcbo-and-rccb-2\/\">\u0417\u0430\u0449\u0438\u0442\u0430 RCBO \u0438 RCCB<\/a> \u043f\u0440\u0435\u0436\u0434\u0435 \u0447\u0435\u043c \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0442\u044c \u0444\u0443\u043d\u043a\u0446\u0438\u0438 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 \u0438 \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430.<\/p>\n<h2>What an LSIG MCCB does<\/h2>\n<p>An <strong>LSIG MCCB<\/strong> provides declared long-time, short-time, instantaneous and ground-fault functions. Its ground-fault function is not automatically equivalent to the high-sensitivity residual-current function required on a final circuit. Voltage, fault duty and sensing arrangements must come from its own exact model table.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u041f\u043e\u043b\u0435<\/th>\n<th>JCR3HM listing<\/th>\n<th>Electronic LSIG MCCB<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u041a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u044f \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u0438<\/td>\n<td>RCCB<\/td>\n<td>MCCB with specified electronic release<\/td>\n<\/tr>\n<tr>\n<td>Overcurrent protection<\/td>\n<td>Separate coordinated device required<\/td>\n<td>Declared L\/S\/I functions<\/td>\n<\/tr>\n<tr>\n<td>Leakage or earth-fault function<\/td>\n<td>Selected residual-current type and sensitivity<\/td>\n<td>Ground-fault function within release scope<\/td>\n<\/tr>\n<tr>\n<td>Voltage<\/td>\n<td>Listed 2P and 4P values<\/td>\n<td>Exact MCCB rating table required<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u0420\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e <a href=\"https:\/\/w9-group.com\/ru\/blog\/importance-of-rccb-in-electrical-safety-protecting-life-and-property\/\">\u0437\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430<\/a> \u043e\u043f\u0438\u0441\u044b\u0432\u0430\u0435\u0442 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043d\u0435\u043b\u044c\u0437\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u0442\u043e\u043b\u044c\u043a\u043e \u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u0438\u0438 \u043c\u0430\u0440\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430.<\/p>\n<p><img decoding=\"async\" alt=\"\u042d\u043b\u0435\u043a\u0442\u0440\u043e\u043d\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c Mccb \u0441 \u0444\u0443\u043d\u043a\u0446\u0438\u0435\u0439 Lsig Trip Unit.jpg\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/upload\/p\/1205\/image_product\/2024-09\/3-pole-acb-drawer-type-fixed-type.jpg\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\" width=\"300\"\/><\/p>\n<h2>Keep the two specifications separate<\/h2>\n<p>For JCR3HM, request poles, current, Type A or AC, <strong>residual-current sensitivity<\/strong> and coordination evidence. For an 800 V MCCB requirement, request a different exact product code with explicit AC or DC operating voltage and fault ratings. Neither product&#8217;s name supplies the other&#8217;s functions.<\/p>\n<table>\n<thead>\n<tr>\n<th>Order<\/th>\n<th>Essential evidence<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>JCR3HM RCCB<\/td>\n<td>RCCB datasheet, wiring and overcurrent coordination<\/td>\n<\/tr>\n<tr>\n<td>800 V MCCB<\/td>\n<td>Exact voltage and fault-duty table, trip curves and connections<\/td>\n<\/tr>\n<tr>\n<td>Complete panel<\/td>\n<td>Assembly verification and installation design<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Installation and procurement checks<\/h2>\n<p>Neutral routing, earthing and test procedures remain important for the RCCB. Use the declared test method and a suitable residual-current tester. IEC 61008-1 and IEC 60947-2 have different product scopes; listing both does not combine two device categories.<\/p>\n<p>Ask W9 Group to confirm the exact required product before quotation. Keep the RCCB and MCCB schedules separate so a misleading legacy title cannot become a purchasing instruction.<\/p>\n<section id=\"faq\">\n<h2>\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h2>\n<h3>Is JCR3HM an 800 V LSIG MCCB?<\/h3>\n<p>No. The reviewed current listing identifies an RCCB with separate overcurrent protection required. It does not establish that combined description.<\/p>\n<h3>Does JCR3HM provide overload protection by itself?<\/h3>\n<p>No. Its RCCB function requires a coordinated MCB or fuse for overload and short-circuit protection.<\/p>\n<h3>Is an MCCB ground-fault function the same as a 30 mA RCD?<\/h3>\n<p>Not automatically. Sensitivity, waveform response, sensing and intended protection differ. Verify the exact functions required by the installation.<\/p>\n<h3>How should an 800 V requirement be quoted?<\/h3>\n<p>Specify a separate exact MCCB with the required AC or DC voltage, fault duty, poles and trip functions. Do not infer it from the JCR3HM name.<\/p>\n<\/section>\n<h2>\u0421\u0441\u044b\u043b\u043a\u0438<\/h2>\n<ul>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/67980\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61008-1:2024 \u2014 RCCB \u0431\u0435\u0437 \u0432\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u043e\u0439 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043e\u043a<\/a>.<\/li>\n<li><a href=\"https:\/\/electrical.theiet.org\/wiring-matters\/years\/2019\/77-september-2019\/which-rcd-type\/\" rel=\"nofollow noopener\" target=\"_blank\">IET \u2014 \u041a\u0430\u043a\u043e\u0439 \u0442\u0438\u043f RCD?<\/a>.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/24656\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60364-6:2016 \u2014 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438<\/a>.<\/li>\n<\/ul>\n<p>\u0414\u043b\u044f \u0432\u044b\u0431\u043e\u0440\u0430 \u0444\u043e\u0440\u043c\u044b \u0432\u043e\u043b\u043d\u044b \u0438 \u043f\u043e\u043b\u044e\u0441\u043e\u0432, <a href=\"https:\/\/w9-group.com\/ru\/%d1%81%d0%b2%d1%8f%d0%b6%d0%b8%d1%82%d0%b5%d1%81%d1%8c-%d1%81-%d0%bd%d0%b0%d0%bc%d0%b8\/\">\u0441\u0432\u044f\u0436\u0438\u0442\u0435\u0441\u044c \u0441 W9 Group<\/a> with the circuit topology, load equipment and destination-market rules.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u041f\u043e\u043b\u0443\u0447\u0438\u0442\u0435 \u043f\u0435\u0440\u0435\u0434\u043e\u0432\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443 \u0441 RCD MCCB 800V JCR3HM. \u0412\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u0430\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u0430 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043e\u043a LSIG \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0443\u044e \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c. \u041d\u0430\u0439\u0434\u0438\u0442\u0435 \u043b\u0443\u0447\u0448\u0438\u0435 \u043f\u0440\u0435\u0434\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0441\u0432\u043e\u0438\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043d\u0443\u0436\u0434<\/p>","protected":false},"author":1,"featured_media":3801,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3409","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/posts\/3409","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/comments?post=3409"}],"version-history":[{"count":4,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/posts\/3409\/revisions"}],"predecessor-version":[{"id":4675,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/posts\/3409\/revisions\/4675"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/media\/3801"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/media?parent=3409"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/categories?post=3409"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/tags?post=3409"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}