{"id":1955,"date":"2026-07-30T11:23:57","date_gmt":"2026-07-30T03:23:57","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/wlm6-2000a-3300-3p-4p-wlm6-series-thermal-magnetic-type-breaker-400v-690v-2000-amp-3-4-poles-1-1-1-p\/"},"modified":"2026-07-30T11:23:59","modified_gmt":"2026-07-30T03:23:59","slug":"wlm6-2000a-3300-3p-4p-wlm6-series-thermal-magnetic-type-breaker-400v-690v-2000-amp-3-4-poles-1-1-1-p","status":"publish","type":"product","link":"https:\/\/w9-group.com\/ko\/product\/wlm6-2000a-3300-3p-4p-wlm6-series-thermal-magnetic-type-breaker-400v-690v-2000-amp-3-4-poles-1-1-1-p\/","title":{"rendered":"WLM7HU-630-3300 3P Photovoltaic solar type molded case circuit breaker solar mccb 800VAC\/1000VAC\/1140VAC 630A 3 Poles"},"content":{"rendered":"<h2>\nMCCB\u00a0Highlights<br \/>\n<\/h2>\n<p>1. Advanced and safe arc extinguishing system structure design;<br \/>\n2. Zero flashover can be achieved by installing the protective cover. Double insulation: pole to pole connection and complete isolation of main circuit;<br \/>\nThe products are widely used in the field of new energy. AC MCCB: series inverter application (power station type): PV string is inverted by inverter DC\/AC, and the output AC is boosted and connected to the grid after being converged by AC combiner box. AC combiner box and low-voltage side of box substation shall be equipped with AC circuit breaker, with working voltage of AC900V \u2192 AC1140V. The operating voltage of direct grid connection mode is relatively low, generally less than AC400V.<\/p>\n<h2>\nMain performance index of WLM7HU series circuit breaker<br \/>\n<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"10\">\nWLM7HU Moulded Case Circuit Breaker<\/td>\n<td colspan=\"3\">630<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated operating current In (A),40\u2103<\/td>\n<td colspan=\"4\">400-500-630<\/td>\n<\/tr>\n<tr><\/tr>\n<tr>\n<td colspan=\"10\">Rated insulation voltage Ui (V)<\/td>\n<td colspan=\"3\">1250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated impulse withstand voltage (kV)<\/td>\n<td colspan=\"3\">12<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated operational voltage Ue(V),AC 50\/60Hz<\/td>\n<td colspan=\"3\">415\/690\/800\/1000\/1140v\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Breaking capacity code<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">M<\/td>\n<td colspan=\"1\">H<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">Number of poles<\/td>\n<td colspan=\"5\">\n3P<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC415V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC690V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">60<\/td>\n<td colspan=\"1\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"5\">\nRated ultimate<br \/>\nshort-circuit breaking<br \/>\ncapacity Icu(kA)\n<\/td>\n<td colspan=\"5\">AC800V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">50<\/td>\n<td colspan=\"1\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC1000V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">20<\/td>\n<td colspan=\"1\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC1140V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">15<\/td>\n<td colspan=\"1\">20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC415V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC690V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">60<\/td>\n<td colspan=\"1\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">\nRated service breaking<br \/>\ncapacity Ics(kA)\n<\/td>\n<td colspan=\"5\">AC800V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">37.5<\/td>\n<td colspan=\"1\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC1000V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">20<\/td>\n<td colspan=\"1\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC1140V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">15<\/td>\n<td colspan=\"1\">20<\/td>\n<\/tr>\n<tr><\/tr>\n<tr>\n<td colspan=\"10\">Standard<\/td>\n<td colspan=\"3\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Utilization category<\/td>\n<td colspan=\"3\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Ambient temperature<\/td>\n<td colspan=\"3\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Safety of insulation<\/td>\n<td colspan=\"3\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Arcing distance<\/td>\n<td colspan=\"3\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\nMechanical life<br \/>\n(CO recycle)\n<\/td>\n<td colspan=\"5\">Maintenance free<\/td>\n<td colspan=\"3\">15000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"1\">\nElectrical life<br \/>\n(CO recycle)\n<\/td>\n<td colspan=\"5\">Maintenance free<\/td>\n<td colspan=\"3\">1000-5000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Release units<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Distribution protection<\/td>\n<td colspan=\"5\">TM<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Mounting and connection<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Fixed<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Plug-in<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Draw-out\n<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DIN rail<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Dimension<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">\nDimension (mm)<br \/>\nW\u00d7H\u00d7D\n<\/td>\n<td colspan=\"5\">Width<\/td>\n<td colspan=\"3\">182<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Height<\/td>\n<td colspan=\"3\">270<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Depth<\/td>\n<td colspan=\"3\">125.8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Weight<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Weight(kg)\/Fixed<\/td>\n<td colspan=\"5\">3P<\/td>\n<td colspan=\"3\">8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\nOverall and installation dimensions of circuit breaker<br \/>\n<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/wlm6-2000a-3300-3p-4p-wlm6-series-thermal-magnetic-type-breaker-400v-690-detail-01-2.webp\" alt=\"WLM7HU-630-3300 3P Photovoltaic solar type molded case circuit breaker solar mccb 800VAC\/1000VAC\/1140VAC 630A 3 Poles detail image 1\" loading=\"lazy\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Rated Current : 630A Number Of Poles : 3P Rated Working Voltage : 800V<\/p>","protected":false},"featured_media":1956,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[96,172,106],"product_tag":[],"class_list":["post-1955","product","type-product","status-publish","has-post-thumbnail","product_cat-hu-voltage-mccb","product_cat-wlm7hu-all-product","product_cat-wlm7hu","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/product\/1955","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/comments?post=1955"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/media\/1956"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/media?parent=1955"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/product_brand?post=1955"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/product_cat?post=1955"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/product_tag?post=1955"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}