{"id":3409,"date":"2026-03-24T09:00:00","date_gmt":"2026-03-24T01:00:00","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/blog\/advanced-protection-of-800v-mccb-electronic-jcr3hm-rcd-with-built-in-lsig-trip-unit\/"},"modified":"2026-10-20T10:37:31","modified_gmt":"2026-10-20T02:37:31","slug":"800v-%eb%a7%a5%ec%8a%a4%ec%bb%a4%eb%b2%84%eb%a6%ac-%ec%a0%84%ec%9e%90-jcr3hm-rcd-%eb%82%b4%ec%9e%a5%eb%90%9c-lsig-%ed%8a%b8%eb%a6%ac%ed%94%84-%ec%9c%a0%eb%8b%9b-%ed%8f%ac%ed%95%a8","status":"publish","type":"post","link":"https:\/\/w9-group.com\/ko\/blog\/advanced-protection-of-800v-mccb-electronic-jcr3hm-rcd-with-built-in-lsig-trip-unit\/","title":{"rendered":"JCR3HM RCCB \ub300 LSIG MCCB: \ubcf4\ud638 \uae30\ub2a5 \ubc0f \ub4f1\uae09 \uc81c\ud55c"},"content":{"rendered":"<p>\uae30\uc874\uc758 \uc81c\ud488\uba85\uc740 \ub450 \uac00\uc9c0 \uc11c\ub85c \ub2e4\ub978 \uc7a5\uce58 \uc0ac\uc591\uc744 \uacb0\ud569\ud55c \uac83\uc73c\ub85c, 800 V \uc804\uc790\uc2dd MCCB(LSIG \uae30\ub2a5 \ud3ec\ud568)\uc640 JCR3HM RCD\ub97c \uc758\ubbf8\ud569\ub2c8\ub2e4. \uc774\ub4e4\uc740 \ud558\ub098\uc758 \uc81c\ud488\uc73c\ub85c \ucde8\uae09\ub418\uc5b4\uc11c\ub294 \uc548 \ub429\ub2c8\ub2e4. \ud604\uc7ac\uc758 JCR3HM \ub4f1\uc7ac \uc790\ub8cc\ub294 <a href=\"https:\/\/w9-group.com\/ko\/%ed%9a%8c%eb%a1%9c-%eb%b3%b4%ed%98%b8-%ec%a0%9c%ed%92%88\/rccb-%ed%9a%8c%eb%a1%9c-%eb%b3%b4%ed%98%b8-%ec%a0%9c%ed%92%88\/\">RCCB<\/a> \uc794\ub958\uc804\ub958 \ubcf4\ud638\ub97c \uc704\ud55c \uac83\uc73c\ub85c, \ubcc4\ub3c4\uc758 \uc870\uc815\ub41c \uacfc\uc804\ub958 \ubcf4\ud638\uac00 \ud544\uc694\ud569\ub2c8\ub2e4.<\/p>\n<p>The <strong>JCR3HM \ub204\uc804\ucc28\ub2e8\uae30<\/strong> \ud45c\uc5d0\ub294 2\uadf9\/4\uadf9, A\ud615 \ub610\ub294 AC\ud615, 30\/100\/300 mA \uc635\uc158\uacfc 25~100 A\uc758 \uc815\uaca9\uc804\ub958 \uc120\ud0dd\uc9c0\uac00 \ub098\uc5f4\ub418\uc5b4 \uc788\uc2b5\ub2c8\ub2e4. 2\uadf9\uc6a9\uc73c\ub85c\ub294 230\/240 V, 4\uadf9\uc6a9\uc73c\ub85c\ub294 400\/415 V\uac00 \uae30\uc7ac\ub418\uc5b4 \uc788\uc2b5\ub2c8\ub2e4. \ub610\ud55c 800 V LSIG MCCB \uc815\uaca9\uc740 \uba85\uc2dc\ub418\uc5b4 \uc788\uc9c0 \uc54a\uc2b5\ub2c8\ub2e4.<\/p>\n<h2>What JCR3HM does<\/h2>\n<p>It detects residual current within the selected waveform and sensitivity scope. An RCCB under IEC 61008-1 has no <strong>integral overcurrent protection<\/strong>. Its current-carrying rating must therefore be coordinated with the circuit&#8217;s MCB or fuse and the manufacturer&#8217;s fault-protection arrangement.<\/p>\n<p>Choose waveform type from the connected load and sensitivity from the protection objective and installation rules. A 300 mA setting cannot simply replace required 30 mA additional protection to avoid trips.<\/p>\n<p>\ucc28\uc774\uc810\uc744 \uac80\ud1a0\ud558\uc2ed\uc2dc\uc624 <a href=\"https:\/\/w9-group.com\/ko\/blog\/what-is-the-difference-between-rcbo-and-rccb-2\/\">RCBO \ubc0f RCCB \ubcf4\ud638<\/a> \uacfc\ubd80\ud558 \ubc0f \ub204\uc804 \uae30\ub2a5\uc744 \ud560\ub2f9\ud558\uae30 \uc804\uc5d0.<\/p>\n<h2>What an LSIG MCCB does<\/h2>\n<p>\ud55c <strong>LSIG MCCB<\/strong> provides declared long-time, short-time, instantaneous and ground-fault functions. Its ground-fault function is not automatically equivalent to the high-sensitivity residual-current function required on a final circuit. Voltage, fault duty and sensing arrangements must come from its own exact model table.<\/p>\n<table>\n<thead>\n<tr>\n<th>\uc601\uc5ed<\/th>\n<th>JCR3HM listing<\/th>\n<th>Electronic LSIG MCCB<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\uc81c\ud488 \uce74\ud14c\uace0\ub9ac<\/td>\n<td>RCCB<\/td>\n<td>MCCB with specified electronic release<\/td>\n<\/tr>\n<tr>\n<td>Overcurrent protection<\/td>\n<td>Separate coordinated device required<\/td>\n<td>Declared L\/S\/I functions<\/td>\n<\/tr>\n<tr>\n<td>Leakage or earth-fault function<\/td>\n<td>Selected residual-current type and sensitivity<\/td>\n<td>Ground-fault function within release scope<\/td>\n<\/tr>\n<tr>\n<td>Voltage<\/td>\n<td>Listed 2P and 4P values<\/td>\n<td>Exact MCCB rating table required<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\uac00\uc774\ub4dc <a href=\"https:\/\/w9-group.com\/ko\/blog\/importance-of-rccb-in-electrical-safety-protecting-life-and-property\/\">\uc794\ub958 \uc804\ub958 \ubcf4\ud638<\/a> describes the installation conditions that a device label alone cannot establish.<\/p>\n<p><img decoding=\"async\" alt=\"800v Mccb \uc804\uc790\uc2dd \ud0c0\uc785 \ub0b4\uc7a5 Lsig \ud2b8\ub9ac\ud504 \uc720\ub2db.jpg\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/upload\/p\/1205\/image_product\/2024-09\/3-pole-acb-drawer-type-fixed-type.jpg\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\" width=\"300\"\/><\/p>\n<h2>Keep the two specifications separate<\/h2>\n<p>For JCR3HM, request poles, current, Type A or AC, <strong>residual-current sensitivity<\/strong> and coordination evidence. For an 800 V MCCB requirement, request a different exact product code with explicit AC or DC operating voltage and fault ratings. Neither product&#8217;s name supplies the other&#8217;s functions.<\/p>\n<table>\n<thead>\n<tr>\n<th>Order<\/th>\n<th>Essential evidence<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>JCR3HM \ub204\uc804\ucc28\ub2e8\uae30<\/td>\n<td>RCCB datasheet, wiring and overcurrent coordination<\/td>\n<\/tr>\n<tr>\n<td>800 V MCCB<\/td>\n<td>Exact voltage and fault-duty table, trip curves and connections<\/td>\n<\/tr>\n<tr>\n<td>Complete panel<\/td>\n<td>Assembly verification and installation design<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Installation and procurement checks<\/h2>\n<p>Neutral routing, earthing and test procedures remain important for the RCCB. Use the declared test method and a suitable residual-current tester. IEC 61008-1 and IEC 60947-2 have different product scopes; listing both does not combine two device categories.<\/p>\n<p>Ask W9 Group to confirm the exact required product before quotation. Keep the RCCB and MCCB schedules separate so a misleading legacy title cannot become a purchasing instruction.<\/p>\n<section id=\"faq\">\n<h2>\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/h2>\n<h3>Is JCR3HM an 800 V LSIG MCCB?<\/h3>\n<p>No. The reviewed current listing identifies an RCCB with separate overcurrent protection required. It does not establish that combined description.<\/p>\n<h3>Does JCR3HM provide overload protection by itself?<\/h3>\n<p>No. Its RCCB function requires a coordinated MCB or fuse for overload and short-circuit protection.<\/p>\n<h3>Is an MCCB ground-fault function the same as a 30 mA RCD?<\/h3>\n<p>Not automatically. Sensitivity, waveform response, sensing and intended protection differ. Verify the exact functions required by the installation.<\/p>\n<h3>How should an 800 V requirement be quoted?<\/h3>\n<p>Specify a separate exact MCCB with the required AC or DC voltage, fault duty, poles and trip functions. Do not infer it from the JCR3HM name.<\/p>\n<\/section>\n<h2>\ucc38\uace0\ubb38\ud5cc<\/h2>\n<ul>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/67980\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61008-1:2024 \u2014 RCCBs without integral overcurrent protection<\/a>.<\/li>\n<li><a href=\"https:\/\/electrical.theiet.org\/wiring-matters\/years\/2019\/77-september-2019\/which-rcd-type\/\" rel=\"nofollow noopener\" target=\"_blank\">IET \u2014 \uc5b4\ub5a4 RCD \ud0c0\uc785\uc778\uac00?<\/a>.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/24656\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60364-6:2016 \u2014 \uc124\uce58 \uac80\uc99d<\/a>.<\/li>\n<\/ul>\n<p>For waveform and pole selection, <a href=\"https:\/\/w9-group.com\/ko\/contact-us\/\">W9 \uadf8\ub8f9\uc5d0 \ubb38\uc758\ud558\uae30<\/a> with the circuit topology, load equipment and destination-market rules.<\/p>","protected":false},"excerpt":{"rendered":"<p>800V JCR3HM RCD MCCB\ub97c \ud1b5\ud574 \uace0\uae09 \ubcf4\ud638 \uae30\ub2a5\uc744 \ubc1b\uc73c\uc138\uc694. \ucd5c\ub300 \uc548\uc804\uc744 \uc704\ud55c \ub0b4\uc7a5\ub41c LSIG \ud2b8\ub9ac\ud504 \uc720\ub2db. \uadc0\ud558\uc758 \uc804\uae30 \uc694\uad6c\uc5d0 \uac00\uc7a5 \uc801\ud569\ud55c \uc81c\ud488\uc744 \ucc3e\uc544\ubcf4\uc138\uc694.<\/p>","protected":false},"author":1,"featured_media":3801,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3409","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/posts\/3409","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/comments?post=3409"}],"version-history":[{"count":4,"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/posts\/3409\/revisions"}],"predecessor-version":[{"id":4675,"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/posts\/3409\/revisions\/4675"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/media\/3801"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/media?parent=3409"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/categories?post=3409"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/w9-group.com\/ko\/wp-json\/wp\/v2\/tags?post=3409"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}