Leave Your Message
JCB1-125 Miniature Circuit Breaker 6kA/10kA

MCB

JCB1-125 Miniature Circuit Breaker 6kA/10kA

Short circuit and overload protection are important functions to ensure the safety and reliability of electrical systems. Breaking capabilities of up to 10kA demonstrate the protection device's ability to handle high fault currents, minimizing the risk of system damage. The inclusion of contact indicators enhances maintenance and troubleshooting processes by visually confirming the status of protective equipment.

In addition, the module width of 27 mm enables efficient use of space in electrical panels and switchboards. Options from 63A to 125A meet a wide range of application needs, providing flexibility in system design. In addition, the availability of 1-pole, 2-pole, 3-pole and 4-pole configurations provides compatibility with a variety of circuit arrangements.

The option to select B, C or D curve characteristics allows customization to specific application requirements, ensuring optimal protection for different types of loads. In addition, compliance with the IEC 60898-1 standard emphasizes compliance with international safety and performance regulations, providing assurance of quality and reliability.

    Introduction

    Designed to deliver superior industrial performance, the JCB1-125 circuit breaker provides robust protection against short circuits and overload currents. Its high breaking capacity of 6kA/10kA makes it an ideal solution for a variety of commercial and heavy industrial applications, ensuring reliable and safe operation.
    The JCB1-125 circuit breaker is constructed from the highest grade components and is designed to ensure reliability in all applications requiring protection from overload and short circuit conditions. Its low voltage multi-standard miniature circuit breaker (MCB) design supports current ratings up to 125A and is frequency compatible with 50Hz or 60Hz.
    The addition of the green strip ensures that the contacts are physically opened, allowing for safe maintenance and repair of downstream circuits.  The JCB1-125 circuit breaker has an operating temperature range of -30°C to 70°C and a storage temperature range of -40°C to 80°C, and is designed to withstand a wide range of environmental conditions.
    The JCB1-125 circuit breaker has excellent overvoltage withstand capability, with an electrical life of up to 5,000 cycles and a mechanical life of up to 20,000 cycles, ensuring long-term reliability in demanding applications. Its 27mm pole width, on/off indicator light and 35mm DIN rail compatibility make it a versatile and convenient mounting option.
    JCB1-125 circuit breaker complies with industrial standards such as IEC 60898-1, EN60898-1, AS/NZS 60898, and residential standards such as IEC60947-2, EN60947-2, AS/NZS 60947-2, and meets strict regulatory requirements. Available in a variety of breaking capacities, these circuit breakers are ideally suited for a variety of applications, making them a reliable and flexible choice for industrial and residential electrical systems.

    Product Description

    JCB1-125dk7

    Main Features
    The most important features
    ● Short circuit and overload protection: Circuit breakers are designed to protect against short circuit and overload conditions, ensuring the safety and reliability of electrical systems.
    ● Breaking Capacity: This product offers breaking capacities of 6kA and 10kA, demonstrating its ability to handle high fault currents and protect circuits from damage.
    ● Width of 27 mm per pole: With a width of 27 mm per pole, the circuit breaker is compact and can effectively utilize the space of switchboards and switchboards.
    ● 35mm DIN Rail Mounting: This product is designed to be easily and securely mounted on a standard 35mm DIN rail for easy installation and maintenance.
    ● With contact indicator: The inclusion of a contact indicator allows visual confirmation of the status of the protective device, thereby enhancing maintenance and troubleshooting procedures.
    ● Current Range 63A to 125A: The circuit breakers are available in rated current ranges from 63A to 125A to meet various applications and load requirements.
    ● Rated impulse withstand voltage (1.2/50) Uimp: The product's rated impulse withstand voltage is 4000V, ensuring protection against transient overvoltage events.
    ● Available in 1-pole, 2-pole, 3-pole, 4-pole: The availability of different pole configurations provides flexibility to suit a variety of circuit arrangements and applications.
    ● C and D curve characteristics available: The circuit breaker is available in C and D curve characteristics, allowing customization according to specific application requirements.
    ● Standard Compliance: The product complies with international standards such as IEC 60898-1, EN60898-1, AS/NZS 60898 and residential standards IEC60947-2, EN60947-2, AS/NZS 60947-2, ensuring compliance with safety and performance regulations.
    JCB1-125-1rxh

    Technical Data

    ● Standards: The circuit breakers comply with international standards such as IEC 60898-1, EN 60898-1, IEC60947-2 and EN60947-2, ensuring compliance with safety and performance regulations.
    ● Rated current: The product is available in 63A, 80A, 100A, and 125A rated current to meet a wide range of applications and load requirements.
    ● Rated working voltage: The rated working voltage can be selected from single-pole 110V, 230V, 240V, three-pole or four-pole 400V to ensure compatibility with various electrical systems.
    ● Rated breaking capacity: Circuit breakers offer rated breaking capacities of 6kA and 10kA, indicating their ability to handle fault currents and protect circuits from damage.
    ● Insulation voltage: The product provides 500V insulation voltage to ensure safe and reliable electricity use.
    ● Rated impulse withstand voltage (1.2/50): The rated impulse withstand voltage of the circuit breaker is 4kV, which can provide transient overvoltage protection.
    ● Thermal magnetic tripper characteristics: The circuit breaker has C-curve and D-curve characteristics, which can be customized according to specific application requirements.
    ● Mechanical life: The product has a mechanical life of up to 20,000 times, ensuring long-term reliability and durability in harsh environments.
    ● Electrical Life: The circuit breaker has an electrical life of 4000 cycles and is designed to provide consistent performance throughout its service life.
    ● Protection level: The protection level of the circuit breaker is IP20, which means its protection against solid objects and limited protection against water intrusion.
    ● Ambient temperature: The working environment temperature range of the circuit breaker is -5℃ to +40℃ (daily average ≤35℃), adapting to a variety of environmental conditions.
    ● Contact position indicator: The circuit breaker has a contact position indicator, green means "OFF" and red means "ON", which can visually confirm the status of the protection device.
    ● Terminal connection type: The circuit breaker supports cable and pin bus terminal connections, allowing flexible installation.
    ● Mounting: The product can be mounted on DIN rail EN 60715 (35mm) using a quick-clamp mechanism for easy and safe installation.
    ● Recommended torque: The recommended torque is 2.5Nm to ensure correct and firm connection during installation, which contributes to the overall reliability of the electrical system.

    Standard IEC/EN 60898-1  IEC/EN 60947-2

    Electrical features

    Rated current In (A) 1, 2, 3, 4, 6, 10, 16,
    20, 25, 32, 40, 50, 63,80
    Poles 1P, 1P+N, 2P, 3P, 3P+N, 4P 1P, 2P, 3P, 4P
    Rated voltage Ue(V) 230/400~240/415
    Insulation voltage Ui (V) 500
    Rated frequency 50/60Hz
    Rated breaking capacity 10 kA
    Energy limiting class 3
    Rated impulse withstand voltage(1.2/50) Uimp (V) 4000
    Dielectric test voltage at ind. Freq. for 1 min (kV) 2
    Pollution degree 2
    Power loss per pole Rated current (A)
    1, 2, 3, 4, 5, 6, 10,13, 16, 20, 25, 32,40, 50, 63, 80
    Thermo-magnetic release characteristic B, C, D 8-12In, 9.6-14.4In

    Mechanical features

    Electrical life 4, 000
    Mechanical life 20, 000
    Contact position indicator Yes
    Protection degree IP20
    Reference temperature for setting of thermal element(℃) 30
    Ambient temperature (with daily average ≤35℃) -5...+40
    Storage temperation (℃) -35...+70
    Installation Terminal connection type Cable/U-type busbar/Pin-type busbar
    Terminal size top/bottom for cable 25mm2  / 18-4 AWG
    Terminal size top/bottom for Busbar 10mm2  / 18-8 AWG
    Tightening torque 2.5 N*m  /  22 In-Ibs.
    Mounting On DIN rail EN 60715 (35mm) by means of fast clip device
    Connection From top and bottom

    Combination
    with
    accessories

    Auxiliary contact Yes
    Shunt release Yes
    Under voltage release Yes
    Alarm contact Yes
    dimensionscx2

    MCCB Production Line Real Showing