{"id":1930,"date":"2026-07-30T11:23:47","date_gmt":"2026-07-30T03:23:47","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/wlm6-1600a-3300-3p-4p-wlm6-series-thermal-magnetic-type-breaker-400v-690v-1600-amp-3-4-poles\/"},"modified":"2026-07-30T11:23:49","modified_gmt":"2026-07-30T03:23:49","slug":"wlm6-1600a-3300-3p-4p-wlm6-series-thermal-magnetic-type-breaker-400v-690v-1600-amp-3-4-poles","status":"publish","type":"product","link":"https:\/\/w9-group.com\/ja\/product\/wlm6-1600a-3300-3p-4p-wlm6-series-thermal-magnetic-type-breaker-400v-690v-1600-amp-3-4-poles\/","title":{"rendered":"MCCB \u65ad\u8def\u5668 WLM6-1600A-3300 3P\/4P WLM6 \u30b7\u30ea\u30fc\u30ba\u30b5\u30fc\u30de\u30eb\u78c1\u6c17\u30bf\u30a4\u30d7\u65ad\u8def\u5668 400V\/690V 1600\u30a2\u30f3\u30da\u30a2 3\/4\u6975"},"content":{"rendered":"<h2>\nMCCB\u00a0Highlights<br \/>\n<\/h2>\n<p>The nylon materials such as the upper cover of ARXM3 are halogen-free VO flame retardant, high and low temperature resistant, aging resistant high-quality plastics, brand: reinforced flame retardant nylon PA66<br \/>\nThe products have longer electrical life and strength, better appearance and higher breaking capacity.<\/p>\n<p><\/p>\n<h2>\nMain performance index of WLM6 series circuit breaker<br \/>\n<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"10\">\nWLM6 Moulded Case Circuit Breaker<\/td>\n<td colspan=\"3\">2000<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" colspan=\"5\">Rated operating\u00a0current In (A),40\u2103<\/td>\n<td colspan=\"5\">Magnetic Type<\/td>\n<td colspan=\"3\">1000-1250-1600-2000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Thermal-magnetic type<\/td>\n<td colspan=\"3\">1000-1250-1600-2000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Adjustable type<\/td>\n<td colspan=\"3\">1000-1250-1600-2000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Electric characteristics<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated insulation voltage Ui (V)<\/td>\n<td colspan=\"3\">1000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated impulse withstand voltage (kV)<\/td>\n<td colspan=\"3\">8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated operational voltage Ue(V),AC 50\/60Hz<\/td>\n<td colspan=\"3\">380\/400\/415,440,500,660\/690\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Breaking capacity code<\/td>\n<td colspan=\"1\">S<\/td>\n<td colspan=\"1\">M<\/td>\n<td colspan=\"1\">H<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"4\">Number of poles<\/td>\n<td colspan=\"5\">1P(Adjutable has no this type)<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">2P<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">3P<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">4P<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"5\">Number of poles<\/td>\n<td colspan=\"5\">AC220\/230\/240V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC380\/400\/415V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">70<\/td>\n<td colspan=\"1\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC440V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC500V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC660\/690V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">20<\/td>\n<td colspan=\"1\">20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"5\">Number of poles<\/td>\n<td colspan=\"5\">AC220\/230\/240V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC380\/400\/415V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">50<\/td>\n<td colspan=\"1\">70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC440V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC500V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC660\/690V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">20<\/td>\n<td colspan=\"1\">20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Standard<\/td>\n<td colspan=\"3\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Utilization category<\/td>\n<td colspan=\"3\">A(Thermal-magnetic)\/B(Electronic)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Ambient temperature<\/td>\n<td colspan=\"3\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Safety of insulation<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Arcing distance<\/td>\n<td colspan=\"3\">0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\nMechanical life<br \/>\n(CO recycle)\n<\/td>\n<td colspan=\"5\">Maintenance<\/td>\n<td colspan=\"3\">8000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">\nElectrical life<br \/>\n(CO recycle)\n<\/td>\n<td colspan=\"5\">AC415V,In<\/td>\n<td colspan=\"3\">1000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC690V,In<\/td>\n<td colspan=\"3\">800<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Release units<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Distribution protection<\/td>\n<td colspan=\"5\">TM<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Motor protection<\/td>\n<td colspan=\"5\">TM<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Mounting and connection<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Fixed<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Plug-in<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Draw-out\n<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DIN rail<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Dimension<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">\nDimension (mm)<br \/>\nW\u00d7H\u00d7D\n<\/td>\n<td colspan=\"5\">Width (1P\/2P\/3P\/4P)<\/td>\n<td colspan=\"3\">210\/280<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Height<\/td>\n<td colspan=\"3\">340<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Depth<\/td>\n<td colspan=\"3\">141<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Weight<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"4\">Distribution protection<\/td>\n<td colspan=\"5\">1P<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">2P<\/td>\n<td colspan=\"3\">&#8211;\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">3P<\/td>\n<td colspan=\"3\">16.46\/16.72\/18.42<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">4P<\/td>\n<td colspan=\"3\">21.4\/22.78\/24.1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\nOverall and installation dimensions of circuit breaker<br \/>\n<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/wlm6-1600a-3300-3p-4p-wlm6-series-thermal-magnetic-type-breaker-400v-690-detail-01.webp\" alt=\"MCCB circuit breaker WLM6-1600A-3300 3P\/4P WLM6 Series thermal magnetic type breaker 400V\/690V 1600 amp 3\/4 Poles detail image 1\" loading=\"lazy\"><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/wlm6-1600a-3300-3p-4p-wlm6-series-thermal-magnetic-type-breaker-400v-690-detail-02.webp\" alt=\"MCCB circuit breaker WLM6-1600A-3300 3P\/4P WLM6 Series thermal magnetic type breaker 400V\/690V 1600 amp 3\/4 Poles detail image 2\" loading=\"lazy\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Rated Current : 1600A\/2000A Number Of Poles : 3P \/ 4P Rated Working Voltage : 400V\/690V<\/p>","protected":false},"featured_media":1931,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[185,173],"product_tag":[],"class_list":["post-1930","product","type-product","status-publish","has-post-thumbnail","product_cat-thermal-mccb-industrial-products","product_cat-wlm6","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/product\/1930","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/comments?post=1930"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/media\/1931"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/media?parent=1930"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/product_brand?post=1930"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/product_cat?post=1930"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/product_tag?post=1930"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}