{"id":1905,"date":"2026-07-30T11:23:37","date_gmt":"2026-07-30T03:23:37","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/wlm6-630a-3300-3p-4p-wlm6-series-thermal-magnetic-type-mccb-400v-690v-630-amp-3-4-poles-poles-poles\/"},"modified":"2026-07-30T11:23:39","modified_gmt":"2026-07-30T03:23:39","slug":"wlm6-630a-3300-3p-4p-wlm6-series-thermal-magnetic-type-mccb-400v-690v-630-amp-3-4-poles-poles-poles","status":"publish","type":"product","link":"https:\/\/w9-group.com\/ja\/product\/wlm6-630a-3300-3p-4p-wlm6-series-thermal-magnetic-type-mccb-400v-690v-630-amp-3-4-poles-poles-poles\/","title":{"rendered":"MCCB \u30b5\u30fc\u30ad\u30c3\u30c8\u30d6\u30ec\u30fc\u30ab WLM6-630A-3300 3P\/4P WLM6 \u30b7\u30ea\u30fc\u30ba\u306e\u30b5\u30fc\u30de\u30eb\u30fb\u30de\u30b0\u30cd\u30c3\u30c8\u5f0f MCCB 400V\/690V 630 \u30a2\u30f3\u30d7 3\/4 \u6975"},"content":{"rendered":"<h2>\nMCCB\u00a0Highlights<br \/>\n<\/h2>\n<p>Surface treatment and processing technology of mechanism parts: QPQ heat treatment technology imported from Germany.<br \/>\n1. We selected the operating mechanism (steel) of W9-Group and another brand sample to compare the experimental results.<br \/>\n2. The operating mechanism of W9 group has a hardness of 366.1, while the hardness of the other brand is only 252.6, which cannot even reach our lowest value.\u00a0\u00a0<br \/>\n3. The mechanical life and electrical life are very important indicators in the national standard of the circuit breaker, and our circuit breaker operating mechanism needs to reach a certain strength and hardness, so that the circuit breaker will not damage the service life of the circuit breaker in the opening and closing process, while the hardness of the other brand is far lower than the national standard.<\/p>\n<p><\/p>\n<h2>\nMain performance index of WLM6 series circuit breaker<br \/>\n<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"10\">\nWLM6 Moulded Case Circuit Breaker<\/td>\n<td colspan=\"4\">630<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" colspan=\"5\">Rated operating\u00a0current In (A),40\u2103<\/td>\n<td colspan=\"5\">Magnetic Type<\/td>\n<td colspan=\"4\">500-630<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Thermal-magnetic type<\/td>\n<td colspan=\"4\">500-630<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Adjustable type<\/td>\n<td colspan=\"4\">500-630<\/td>\n<\/tr>\n<tr>\n<td colspan=\"14\">Electric characteristics<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated insulation voltage Ui (V)<\/td>\n<td colspan=\"4\">1000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated impulse withstand voltage (kV)<\/td>\n<td colspan=\"4\">8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated operational voltage Ue(V),AC 50\/60Hz<\/td>\n<td colspan=\"4\">380\/400\/415,440,500,660\/690<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Breaking capacity code<\/td>\n<td colspan=\"1\">S<\/td>\n<td colspan=\"1\">M<\/td>\n<td colspan=\"1\">H<\/td>\n<td colspan=\"1\">Q<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"4\">Number of poles<\/td>\n<td colspan=\"5\">1P(Adjutable has no this type)<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">2P<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">3P<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">4P<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"5\">Number of poles<\/td>\n<td colspan=\"5\">AC220\/230\/240V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">80<\/td>\n<td colspan=\"1\">85<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC380\/400\/415V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">70<\/td>\n<td colspan=\"1\">100<\/td>\n<td colspan=\"1\">150<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC440V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC500V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC660\/690V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">10<\/td>\n<td colspan=\"1\">20<\/td>\n<td colspan=\"1\">20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"5\">Number of poles<\/td>\n<td colspan=\"5\">AC220\/230\/240V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">30<\/td>\n<td colspan=\"1\">50<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC380\/400\/415V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">50<\/td>\n<td colspan=\"1\">70<\/td>\n<td colspan=\"1\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC440V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC500V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC660\/690V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">10<\/td>\n<td colspan=\"1\">12<\/td>\n<td colspan=\"1\">20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"14\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Standard<\/td>\n<td colspan=\"4\">IEC\/EN 60947-2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Utilization category<\/td>\n<td colspan=\"4\">A(Thermal-magnetic)\/B(Electronic)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Ambient temperature<\/td>\n<td colspan=\"4\">-40\u2103 ~+70 \u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Safety of insulation<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Arcing distance<\/td>\n<td colspan=\"4\">0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\nMechanical life<br \/>\n(CO recycle)\n<\/td>\n<td colspan=\"5\">Maintenance<\/td>\n<td colspan=\"4\">15000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">\nElectrical life<br \/>\n(CO recycle)\n<\/td>\n<td colspan=\"5\">AC415V,In<\/td>\n<td colspan=\"4\">8000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC690V,In<\/td>\n<td colspan=\"4\">1500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"14\">Release units<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Distribution protection<\/td>\n<td colspan=\"5\">TM<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Motor protection<\/td>\n<td colspan=\"5\">TM<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"14\">Mounting and connection<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Fixed<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Plug-in<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Draw-out\n<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DIN rail<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"4\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"14\">Dimension<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">\nDimension (mm)<br \/>\nW\u00d7H\u00d7D\n<\/td>\n<td colspan=\"5\">Width (1P\/2P\/3P\/4P)<\/td>\n<td colspan=\"4\">140\/184<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Height<\/td>\n<td colspan=\"4\">257<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Depth<\/td>\n<td colspan=\"4\">103\/111(Q TYPE)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"14\">Weight<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"4\">Distribution protection<\/td>\n<td colspan=\"5\">1P<\/td>\n<td colspan=\"4\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">2P<\/td>\n<td colspan=\"4\">&#8211;\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">3P<\/td>\n<td colspan=\"4\">5.23\/6\uff08Q type\uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">4P<\/td>\n<td colspan=\"4\">6.809\/7.3\uff08Q type\uff09<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\nOverall and installation dimensions of circuit breaker<br \/>\n<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/wlm6-400a-3300-3p-4p-wlm6-series-400vac-thermal-magnetic-type-moulded-ca-detail-01.webp\" alt=\"MCCB circuit breaker WLM6-630A-3300 3P\/4P WLM6 Series thermal magnetic type mccb 400V\/690V 630 amp 3\/4 Poles detail image 1\" loading=\"lazy\"><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/wlm6-400a-3300-3p-4p-wlm6-series-400vac-thermal-magnetic-type-moulded-ca-detail-02.webp\" alt=\"MCCB circuit breaker WLM6-630A-3300 3P\/4P WLM6 Series thermal magnetic type mccb 400V\/690V 630 amp 3\/4 Poles detail image 2\" loading=\"lazy\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Rated Current : 630A Number Of Poles : 3P \/ 4P Rated Working Voltage : 400V\/690V<\/p>","protected":false},"featured_media":1906,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[185,173],"product_tag":[],"class_list":["post-1905","product","type-product","status-publish","has-post-thumbnail","product_cat-thermal-mccb-industrial-products","product_cat-wlm6","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/product\/1905","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/comments?post=1905"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/media\/1906"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/media?parent=1905"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/product_brand?post=1905"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/product_cat?post=1905"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/product_tag?post=1905"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}