{"id":3506,"date":"2026-07-14T09:00:00","date_gmt":"2026-07-14T01:00:00","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/blog\/choosing-acb-circuit-breaker-for-industrial-needs\/"},"modified":"2026-10-15T11:16:42","modified_gmt":"2026-10-15T03:16:42","slug":"%e7%94%a3%e6%a5%ad%e7%94%a8%e5%90%91%e3%81%91acb%e9%81%ae%e6%96%ad%e5%99%a8%e3%81%ae%e9%81%b8%e6%8a%9e","status":"publish","type":"post","link":"https:\/\/w9-group.com\/ja\/blog\/choosing-acb-circuit-breaker-for-industrial-needs\/","title":{"rendered":"\u7523\u696d\u7528\u9014\u5411\u3051ACB\u906e\u65ad\u5668\u306e\u9078\u3073\u65b9"},"content":{"rendered":"<div data-content-revision=\"topic-research-geo information-gain\" data-revision-date=\"2026-10-15\">\n<p>An industrial main breaker is part of the switchboard&#8217;s operating plan as well as its protection system. A quote that states only current and voltage leaves unanswered how faults are cleared, how maintenance is performed and whether a replacement unit fits the existing assembly. Resolve these questions before freezing the <strong>ACB schedule<\/strong>.<\/p>\n<p>Summary: Choose an ACB circuit breaker by starting with system voltage, continuous load, prospective short-circuit current and the required selectivity study\u2014not by frame size alone. IEC 60947-2 addresses low-voltage circuit-breaker performance, while UL 1066 covers low-voltage AC power circuit breakers used in North American practice; the applicable standard changes the evidence your supplier must provide. Build a written schedule for frame and trip ratings, fixed or withdrawable construction, protection functions, environment and maintenance, then verify the complete assembly before purchase.<\/p>\n<h2>ACB Electrical Duty Requirements<\/h2>\n<p>ACB\u56de\u8def\u906e\u65ad\u5668\u306f\u3001\u9ad8\u96fb\u6d41\u3001\u983b\u7e41\u306a\u30b9\u30a4\u30c3\u30c1\u30f3\u30b0\u3001\u307e\u305f\u306f\u30b5\u30fc\u30d3\u30b9\u30a2\u30af\u30bb\u30b9\u306b\u3088\u308a\u6210\u5f62\u30b1\u30fc\u30b9\u5f0f\u88c5\u7f6e\u304c\u4e0d\u9069\u5207\u3068\u306a\u308b\u3088\u3046\u306a\u4f4e\u96fb\u5727\u30a2\u30bb\u30f3\u30d6\u30ea\u306b\u304a\u3044\u3066\u3001\u901a\u5e38\u30e1\u30a4\u30f3\u307e\u305f\u306f\u30d5\u30a7\u30fc\u30c0\u30fc\u4fdd\u8b77\u88c5\u7f6e\u3068\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u5f79\u5272\u306b\u304a\u3044\u3066\u3001\u7523\u696d\u7528\u56de\u8def\u906e\u65ad\u5668\u306f\u3001\u5358\u306a\u308b\u30ab\u30bf\u30ed\u30b0\u54c1\u3067\u306f\u306a\u304f\u3001\u30d7\u30e9\u30f3\u30c8\u306e\u904b\u7528\u6226\u7565\u306e\u4e00\u90e8\u3068\u306a\u308a\u307e\u3059\u3002\u30b7\u30b9\u30c6\u30e0\u306e\u5b9a\u683c\u96fb\u5727\u3001\u5468\u6ce2\u6570\u3001\u4f4d\u76f8\u914d\u7f6e\u3001\u304a\u3088\u3073\u63a5\u5730\u65b9\u6cd5\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u30e2\u30fc\u30bf\u30fc\u3001\u30c8\u30e9\u30f3\u30b9\u3001\u30c9\u30e9\u30a4\u30d6\u3001\u30d2\u30fc\u30bf\u30fc\u3001\u304a\u3088\u3073\u4eca\u5f8c\u306e\u62e1\u5f35\u3092\u542b\u3081\u305f\u5b9f\u969b\u306e\u8ca0\u8377\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u304b\u3089\u8a2d\u8a08\u96fb\u6d41\u3092\u8a08\u7b97\u3057\u307e\u3059\u3002.<\/p>\n<p>\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u306b3\u3064\u306e\u8a55\u4fa1\u9805\u76ee\u3092\u5206\u3051\u3066\u304f\u3060\u3055\u3044\u3002\u30d5\u30ec\u30fc\u30e0\u8a55\u4fa1\uff08\u7269\u7406\u7684\u306a\u96fb\u6d41\u30af\u30e9\u30b9\uff09\u3001\u30c8\u30ea\u30c3\u30d7\u30e6\u30cb\u30c3\u30c8\u307e\u305f\u306f\u30bb\u30f3\u30b5\u30fc\u8a55\u4fa1\uff08\u4fdd\u8b77\u306e\u57fa\u6e96\u3068\u306a\u308b\u96fb\u6d41\uff09\u3001\u304a\u3088\u3073\u9577\u671f\u30d4\u30c3\u30af\u30a2\u30c3\u30d7\u8a2d\u5b9a\uff08\u9078\u629e\u3057\u305f\u52d5\u4f5c\u95be\u5024\uff09\u3002\u3088\u308a\u5927\u304d\u306a\u30d5\u30ec\u30fc\u30e0\u306f\u81ea\u52d5\u7684\u306b\u3088\u308a\u9ad8\u3044\u4f7f\u7528\u53ef\u80fd\u306a\u5bb9\u91cf\u3092\u63d0\u4f9b\u3059\u308b\u308f\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u30c8\u30ea\u30c3\u30d7\u30e6\u30cb\u30c3\u30c8\u3092\u904e\u5ea6\u306b\u9ad8\u3081\u306b\u8a2d\u5b9a\u3059\u308b\u3068\u30b3\u30f3\u30c0\u30af\u30bf\u30fc\u304c\u4fdd\u8b77\u3055\u308c\u306a\u304f\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u4e00\u65b9\u3001\u904e\u5ea6\u306b\u4f4e\u3081\u306b\u8a2d\u5b9a\u3059\u308b\u3068\u52d5\u4f5c\u304c\u7169\u308f\u3057\u304f\u306a\u308a\u304b\u306d\u307e\u305b\u3093\u3002\u30e1\u30fc\u30ab\u30fc\u304b\u3089\u6642\u9593-\u96fb\u6d41\u66f2\u7dda\u304a\u3088\u3073\u6307\u5b9a\u3055\u308c\u3066\u3044\u308b\u6b63\u78ba\u306a\u30bb\u30f3\u30b5\u30fc\u304a\u3088\u3073\u30c8\u30ea\u30c3\u30d7\u30aa\u30d7\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n<p>Short-circuit duty is equally important. Obtain the calculated prospective fault current at the installation point and compare it with the breaker\u2019s interrupting rating and <strong>short-time withstand rating<\/strong> at the stated voltage. If the design relies on a downstream device clearing a fault after a short delay, the ACB must withstand that current for the specified duration. Do not substitute a headline interrupting number for a coordinated withstand check.<\/p>\n<figure>\n<img decoding=\"async\" alt=\"Existing W9 ACB article illustration\" loading=\"lazy\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2025\/11\/top-air-circuit-breaker-factories-exceptional-quality-innovation-content-02.webp\"\/><figcaption>Existing W9 ACB article illustration.<\/figcaption><\/figure>\n<h3>Short-Time Withstand Duration<\/h3>\n<p>Icw is a short-time withstand rating with a specified duration; it is not an interrupting capacity. If the protection design intentionally delays an upstream ACB, compare the duty during that delay with both breaker and assembly withstand. Check any instantaneous override or other restriction in the exact trip-unit documentation. A coordination drawing that ignores a mandatory override can overstate selectivity.<\/p>\n<h2>ACB Construction Requirements<\/h2>\n<p>A fixed ACB remains installed in its mounting arrangement, while a <a href=\"https:\/\/w9-group.com\/ja\/blog\/air-circuit-breaker-types-understanding-the-various-types-and-their-applications\/\">withdrawable model<\/a> uses a compatible cradle with declared connected, test and disconnected positions. The exact position functions must be confirmed from the instructions. Withdrawal can support a planned maintenance or spare strategy; it <strong>does not make the entire compartment de-energized<\/strong> or authorize work on live equipment. Record the isolation and racking procedures before selecting this format.<\/p>\n<p>\u8a2d\u8a08\u30ec\u30d3\u30e5\u30fc\u306e\u969b\u306b\u4ee5\u4e0b\u306e\u6bd4\u8f03\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<table>\n<thead>\n<tr>\n<th>\u6c7a\u5b9a\u6b21\u5143<\/th>\n<th>\u56fa\u5b9a\u69cb\u9020<\/th>\n<th>\u53d6\u308a\u5916\u3057\u53ef\u80fd\u306a\u69cb\u9020<\/th>\n<th>\u3074\u3063\u305f\u308a\u306a\u30b5\u30a4\u30ba<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u521d\u671f\u306e\u7d71\u5408<\/td>\n<td>\u6a5f\u68b0\u90e8\u54c1\u304c\u5c11\u306a\u3044\uff1b\u30d1\u30cd\u30eb\u30ec\u30a4\u30a2\u30a6\u30c8\u304c\u30b7\u30f3\u30d7\u30eb<\/td>\n<td>\u30af\u30ec\u30fc\u30c9\u30eb\u3001\u4f4d\u7f6e\u8868\u793a\u3001\u30ed\u30c3\u30af\u6a5f\u69cb\u304c\u5fc5\u8981\u3067\u3059<\/td>\n<td>\u5b89\u5b9a\u6027\u3068\u30b9\u30da\u30fc\u30b9\u306e\u5236\u7d04\u306e\u3042\u308b\u30dc\u30fc\u30c9\u5411\u3051\u306b\u4fee\u6b63<\/td>\n<\/tr>\n<tr>\n<td>\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30a2\u30af\u30bb\u30b9<\/td>\n<td>\u9694\u96e2\u3068\u5207\u308a\u96e2\u3057\u306f\u901a\u5e38\u5fc5\u8981\u3067\u3042\u308b\u3002<\/td>\n<td>\u30c6\u30b9\u30c8\u307e\u305f\u306f\u30b5\u30fc\u30d3\u30b9\u8077\u306f\u8a08\u753b\u3055\u308c\u305f\u4f5c\u696d\u3092\u30b5\u30dd\u30fc\u30c8\u3059\u308b<\/td>\n<td>\u91cd\u8981\u306a\u8a2d\u5099\u307e\u305f\u306f\u9023\u7d9a\u904b\u8ee2\u8a2d\u5099\u3067\u306e\u53d6\u308a\u51fa\u3057\u304c\u53ef\u80fd<\/td>\n<\/tr>\n<tr>\n<td>\u4e88\u5099\u7684\u306a\u6226\u7565<\/td>\n<td>\u4ea4\u63db\u306f\u6a5f\u5668\u3054\u3068\u306b\u7570\u306a\u308a\u307e\u3059\u3002<\/td>\n<td>\u4e92\u63db\u6027\u306e\u3042\u308b\u30b9\u30da\u30a2\u30d1\u30fc\u30c4\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u505c\u96fb\u671f\u9593\u3092\u77ed\u7e2e\u3067\u304d\u307e\u3059\u3002<\/td>\n<td>\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u304c\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u5834\u5408\u3001\u53d6\u308a\u51fa\u3057\u53ef\u80fd<\/td>\n<\/tr>\n<tr>\n<td>\u7dcf\u8cbb\u7528<\/td>\n<td>\u30cf\u30fc\u30c9\u30a6\u30a7\u30a2\u306e\u6545\u969c\u306e\u767a\u751f\u7387\u304c\u4f4e\u304f\u306a\u308b\uff1b\u505c\u6b62\u4f5c\u696d\u3092\u691c\u8a0e\u3059\u308b<\/td>\n<td>\u30cf\u30fc\u30c9\u30a6\u30a7\u30a2\u306e\u50be\u5411\u304c\u9ad8\u304f\u306a\u308b\uff1b\u30e9\u30a4\u30d5\u30b5\u30a4\u30af\u30eb\u3067\u306e\u53ef\u7528\u6027\u3092\u8003\u616e\u3059\u308b<\/td>\n<td>\u8cfc\u5165\u4fa1\u683c\u3067\u306f\u306a\u304f\u3001\u7dcf\u6240\u6709\u30b3\u30b9\u30c8\u3092\u6c7a\u5b9a\u3059\u308b<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u30c9\u30a2\u306e\u30af\u30ea\u30a2\u30e9\u30f3\u30b9\u3001\u30b1\u30fc\u30d6\u30eb\u7d42\u7aef\u3001\u30a2\u30fc\u30c1\u969c\u5bb3\u5883\u754c\u3001\u6301\u3061\u4e0a\u3052\u30a2\u30af\u30bb\u30b9\u3001\u304a\u3088\u3073\u30e1\u30fc\u30ab\u30fc\u306e\u30e9\u30c3\u30af\u914d\u7f6e\u624b\u9806\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ea\u30c8\u30e9\u30d0\u30fc\u30d6\u30eb\u306a\u8a2d\u8a08\u306f\u3001\u30aa\u30da\u30ec\u30fc\u30bf\u304c\u5b89\u5168\u306b\u8a66\u9a13\u4f4d\u7f6e\u306b\u5230\u9054\u3067\u304d\u308b\u5834\u5408\u306b\u306e\u307f\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u4e0a\u306e\u30e1\u30ea\u30c3\u30c8\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30a2\u30bb\u30f3\u30d6\u30ea\u306e\u30a4\u30f3\u30bf\u30fc\u30ed\u30c3\u30af\u3082\u8a18\u9332\u3055\u308c\u3066\u3044\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002.<\/p>\n<h2>ACB Protection Coordination<\/h2>\n<p>\u9078\u629e\u6027\uff08\u5dee\u5225\uff09\u3068\u306f\u3001\u969c\u5bb3\u306e\u3042\u308b\u7b87\u6240\u306b\u8fd1\u3044\u88c5\u7f6e\u304c\u6700\u521d\u306b\u4f5c\u52d5\u3057\u3001\u5065\u5168\u306a\u8ca0\u8377\u3092\u7dad\u6301\u3059\u308b\u3053\u3068\u3092\u793a\u3057\u307e\u3059\u3002ACB\u304a\u3088\u3073\u4e0b\u6d41\u30d6\u30ec\u30fc\u30ab\u306b\u304a\u3051\u308b\u9577\u671f\u8a2d\u5b9a\u3001\u77ed\u6642\u9593\u8a2d\u5b9a\u3001\u77ac\u6642\u8a2d\u5b9a\u3001\u304a\u3088\u3073\u63a5\u5730\u969c\u5bb3\u8a2d\u5b9a\u3092\u6bd4\u8f03\u3057\u307e\u3059\u3002\u6642\u9593\u96fb\u6d41\u66f2\u7dda\u306f\u4e0d\u53ef\u6b20\u3067\u3059\u304c\u3001\u96fb\u5b50\u5f0f\u30c8\u30ea\u30c3\u30d7\u30e6\u30cb\u30c3\u30c8\u3067\u306f\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u901a\u904e\u3082\u5fc5\u8981\u306b\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<sup>2<\/sup>t\u3001\u307e\u305f\u306f\u30be\u30fc\u30f3\u9078\u629e\u578b\u30a4\u30f3\u30bf\u30fc\u30ed\u30c3\u30af\u30c7\u30fc\u30bf\u3002\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u3067\u30be\u30fc\u30f3\u30a4\u30f3\u30bf\u30fc\u30ed\u30c3\u30af\u3001\u901a\u4fe1\u3001\u30e1\u30fc\u30bf\u30ea\u30f3\u30b0\u3001\u307e\u305f\u306f\u30b7\u30e3\u30f3\u30c8\/\u4f4e\u96fb\u5727\u30ea\u30ea\u30fc\u30b9\u306e\u5fc5\u8981\u6027\u304c\u3042\u308b\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002.<\/p>\n<p>For an industrial circuit breaker, the assembly interface matters. Busbar bracing, terminals, source impedance, cable arrangement and the selected protective settings affect the fault review. Require a switchboard verification route in addition to breaker product evidence. Include transformer, generator and other credible supply contributions under their relevant operating states. Review the <a href=\"https:\/\/w9-group.com\/ja\/blog\/the-ultimate-guide-to-circuit-breakers-and-their-advanced-trip-devices\/\">\u9ad8\u5ea6\u306a\u65c5\u884c\u6a5f\u5668\u306e\u30ac\u30a4\u30c9<\/a> as background, then use the exact manufacturer&#8217;s curves and coordination tables.<\/p>\n<p><em>\u8aac\u660e\u7684\u306a\u8a08\u7b97\uff08\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u8a2d\u8a08\u3067\u306f\u306a\u3044\uff09\uff1a<\/em> 3\u76f8\u8ca0\u8377\u306e\u96fb\u5727\u306f400 V\u30671,200 kW\u3001\u96fb\u529b\u4fc2\u6570\u306f0.90\u3067\u3042\u308b\u5834\u5408\u3001\u63a8\u5b9a\u96fb\u6d41\u306fI = 1,200,000\/(\u221a3 \u00d7 400 \u00d7 0.90) \u2248 1,925 A\u3068\u306a\u308a\u307e\u3059\u3002\u30a8\u30f3\u30b8\u30cb\u30a2\u306f\u305d\u306e\u5f8c\u3001\u30c7\u30e5\u30fc\u30c6\u30a3\u30b5\u30a4\u30af\u30eb\u3001\u5468\u56f2\u306e\u6027\u80fd\u4f4e\u4e0b\u3001\u9ad8\u8abf\u6ce2\u3001\u30e2\u30fc\u30bf\u30fc\u306e\u59cb\u52d5\u3001\u304a\u3088\u3073\u30b3\u30fc\u30c9\u8981\u56e0\u3092\u9069\u7528\u3057\u3001\u30bb\u30f3\u30b5\u30fc\u8a2d\u5b9a\u307e\u305f\u306f\u30d5\u30ec\u30fc\u30e0\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u3053\u306e\u4f8b\u306f\u3001\u96fb\u5727\u3068\u96fb\u529b\u4fc2\u6570\u304c\u96fb\u6d41\u8981\u4ef6\u3068\u3068\u3082\u306b\u5fc5\u8981\u3067\u3042\u308b\u7406\u7531\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002.<\/p>\n<h2>ACB Installation Environment<\/h2>\n<p>\u6e29\u5ea6\u3001\u9ad8\u5ea6\u3001\u6e7f\u5ea6\u3001\u307b\u3053\u308a\u3001\u8150\u98df\u6027\u84b8\u6c17\u3001\u632f\u52d5\u306f\u3001ACB\u56de\u8def\u30d6\u30ec\u30fc\u30ab\u30fc\u306e\u8010\u7528\u5b9a\u683c\u304a\u3088\u3073\u4fdd\u5b88\u5468\u671f\u3092\u5909\u5316\u3055\u305b\u307e\u3059\u3002\u5b9f\u969b\u306e\u7b50\u4f53\u304a\u3088\u3073\u5468\u56f2\u6761\u4ef6\u306e\u30c7\u30ec\u30fc\u30c6\u30a3\u30f3\u30b0\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u4e00\u822c\u7684\u306a\u30ab\u30bf\u30ed\u30b0\u30da\u30fc\u30b8\u304b\u3089\u63a8\u6e2c\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002\u307b\u3053\u308a\u3084\u5316\u5b66\u7684\u306b\u653b\u6483\u7684\u306a\u74b0\u5883\u3067\u306f\u3001\u30d1\u30cd\u30eb\u30e1\u30fc\u30ab\u30fc\u306b\u30b7\u30fc\u30eb\u3001\u30af\u30ea\u30fc\u30d7\u3001\u30af\u30ea\u30a2\u30e9\u30f3\u30b9\u306e\u8981\u4ef6\u3092\u660e\u793a\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30d1\u30cd\u30eb\u306e\u30ec\u30a4\u30a2\u30a6\u30c8\u304c\u78ba\u5b9a\u3059\u308b\u524d\u306b\u3001\u3053\u308c\u3089\u306e\u6761\u4ef6\u306b\u5408\u308f\u305b\u3066\u7523\u696d\u7528\u56de\u8def\u30d6\u30ec\u30fc\u30ab\u30fc\u3092\u691c\u8a0e\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n<p>Define maintenance before approving the bill of materials. The plan should follow the manufacturer on inspection, cleaning, permitted lubrication, mechanical operation, contact-wear assessment and trip testing. Do not set a universal service interval or apply cleaning and lubrication methods from a different breaker family. Record firmware and setting changes where applicable, and compare the outage, service and spare costs without inventing a saving.<\/p>\n<p>ACB\u306e\u53b3\u683c\u306a\u9078\u8003\u30ec\u30d3\u30e5\u30fc\u3067\u306f\u3001\u5404\u6c7a\u5b9a\u6a29\u8005\u306e\u6c0f\u540d\u3082\u8a18\u9332\u3055\u308c\u307e\u3059\u3002\u96fb\u6c17\u6280\u5e2b\u306f\u4f5c\u696d\u306e\u8cac\u4efb\u3068\u9023\u643a\u3092\u78ba\u8a8d\u3057\u3001\u30d1\u30cd\u30eb\u306e\u7d44\u307f\u7acb\u3066\u62c5\u5f53\u8005\u306f\u30af\u30ea\u30a2\u30e9\u30f3\u30b9\u3068\u30a4\u30f3\u30bf\u30fc\u30ed\u30c3\u30af\u3092\u78ba\u8a8d\u3057\u3001\u30aa\u30da\u30ec\u30fc\u30bf\u30fc\u306f\u30a2\u30af\u30bb\u30b9\u3068\u30c6\u30b9\u30c8\u624b\u9806\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002.<\/p>\n<figure>\n<img decoding=\"async\" alt=\"Existing W9 article image for breaker maintenance context\" loading=\"lazy\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2025\/11\/top-air-circuit-breaker-factories-exceptional-quality-innovation-content-07.webp\"\/><figcaption>Existing W9 article image for breaker maintenance context.<\/figcaption><\/figure>\n<figure>\n<img decoding=\"async\" alt=\"Existing W9 article image for switchboard interface context\" loading=\"lazy\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2025\/11\/top-air-circuit-breaker-factories-exceptional-quality-innovation-content-11.webp\"\/><figcaption>Existing W9 article image for switchboard interface context.<\/figcaption><\/figure>\n<h3>Complete ACB Spare Requirements<\/h3>\n<p>A drawout spare must match the cradle, terminals, interlocks, sensor or trip configuration and required accessories. Same frame current alone does not prove interchangeability. Ask for the <strong>approved breaker-cradle combination<\/strong> and record commissioning settings before swapping units. Compare the cost of the spare, storage, periodic checks, handling equipment and planned outage labour; the calculation is a project-specific ownership-cost framework, not a promised payback.<\/p>\n<h2>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30d9\u30fc\u30b9\u306eACB\u9078\u629e<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u7533\u8acb<\/th>\n<th>\u4e3b\u306a\u61f8\u5ff5\u4e8b\u9805<\/th>\n<th>\u4ed5\u69d8\u306e\u5f37\u8abf<\/th>\n<th>\u6709\u7528\u306a\u8a3c\u62e0<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u88fd\u9020\u696d\u306e\u4e3b\u306a\u9867\u5ba2<\/td>\n<td>\u9ad8\u3044\u6545\u969c\u8010\u6027\u3068\u9023\u7d9a\u6027<\/td>\n<td>\u8010\u885d\u6483\u6027\u3001\u9078\u629e\u6027\u3001\u53d6\u308a\u5916\u3057\u53ef\u80fd\u306a\u30aa\u30d7\u30b7\u30e7\u30f3\u3001\u30b5\u30fc\u30d3\u30b9\u7528\u30b9\u30da\u30a2\u30d1\u30fc\u30c4<\/td>\n<td>\u30b7\u30e7\u30fc\u30c8\u30fb\u30b5\u30fc\u30ad\u30c3\u30c8\u7814\u7a76\u3001\u9023\u643a\u56f3\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb<\/td>\n<\/tr>\n<tr>\n<td>\u30c7\u30fc\u30bf\u3084\u30d7\u30ed\u30bb\u30b9\u306b\u91cd\u8981\u306a\u8a2d\u5099<\/td>\n<td>\u8fc5\u901f\u306a\u5fa9\u65e7\u3068\u76e3\u8996<\/td>\n<td>\u53d6\u308a\u5916\u3057\u53ef\u80fd\u306a\u69cb\u9020\u3001\u4f4d\u7f6e\u30ed\u30c3\u30af\u3001\u901a\u4fe1\u6a5f\u80fd<\/td>\n<td>\u30e9\u30c3\u30af\u624b\u9806\u3001\u30a2\u30e9\u30fc\u30e0\u4e00\u89a7\u3001\u30c6\u30b9\u30c8\u8a18\u9332<\/td>\n<\/tr>\n<tr>\n<td>OEM\u578b\u96fb\u6e90\u5236\u5fa1\u30d1\u30cd\u30eb<\/td>\n<td>\u30d3\u30eb\u30c9\u9593\u306e\u518d\u73fe\u6027<\/td>\n<td>\u5b89\u5b9a\u3057\u305f\u30d5\u30ec\u30fc\u30e0\/\u30c8\u30ea\u30c3\u30d7\u69cb\u6210\u3001\u4ed8\u5c5e\u54c1\u3001\u56f3\u9762<\/td>\n<td>\u627f\u8a8d\u3055\u308c\u305f\u6750\u6599\u8868\u3001\u914d\u7dda\u56f3\u3001\u691c\u67fb\u8a08\u753b<\/td>\n<\/tr>\n<tr>\n<td>\u516c\u76ca\u4e8b\u696d\u307e\u305f\u306f\u30a4\u30f3\u30d5\u30e9\u59d4\u54e1\u4f1a<\/td>\n<td>\u904e\u9177\u306a\u74b0\u5883\u3068\u9577\u5e74\u306e\u4f7f\u7528<\/td>\n<td>\u30c7\u30ec\u30fc\u30c6\u30a3\u30f3\u30b0\u3001\u30a8\u30f3\u30af\u30ed\u30fc\u30b8\u30e3 \u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u3001\u8010\u8150\u98df\u6027\u3001\u30b9\u30da\u30a2\u30d1\u30fc\u30c4<\/td>\n<td>\u74b0\u5883\u30c7\u30fc\u30bf\u3001\u7d44\u7acb\u78ba\u8a8d\u3001\u30b5\u30fc\u30d3\u30b9\u30b5\u30dd\u30fc\u30c8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>ACB Compliance Requirements<\/h2>\n<p>IEC 60947-2 specifies requirements and verification tests for circuit breakers used in low-voltage switchgear and controlgear. It is a product standard; confirm the declared ratings and test evidence for the exact configuration. UL 1066 is the North American standard for low-voltage AC power circuit breakers, with construction and performance requirements that may differ from an IEC declaration. A project using UL-listed equipment must verify the listing, installation conditions and marking through the applicable certification body.<\/p>\n<p>NFPA 70 (National Electrical Code) governs electrical installation in the United States. It addresses conductor protection, equipment ratings, working space and other installation matters; it does not replace the breaker product standard. Requirements depend on destination market, system architecture and the authority having jurisdiction. Unsupported claims such as \u201cUL compliant\u201d or \u201cIEC certified\u201d can delay approval, invalidate a tender response or create warranty disputes.<\/p>\n<h2>ACB Supplier Evaluation Checklist<\/h2>\n<ol>\n<li>\u96fb\u5727\u3001\u9023\u7d9a\u96fb\u6d41\u3001\u30dd\u30fc\u30eb\u6570\u3001\u5468\u6ce2\u6570\u3001\u6545\u969c\u96fb\u6d41\u3001\u8010\u96fb\u5727\u6642\u9593\u3001\u30c8\u30ea\u30c3\u30d7\u6a5f\u80fd\u304a\u3088\u3073\u5468\u56f2\u6761\u4ef6\u3092\u793a\u3059\u30c7\u30fc\u30bf\u30b7\u30fc\u30c8\u3092\u767a\u884c\u3059\u308b\u3002.<\/li>\n<li>\u505c\u96fb\u30b3\u30b9\u30c8\u3001\u30b9\u30da\u30fc\u30b9\u3001\u30a4\u30f3\u30bf\u30fc\u30ed\u30c3\u30af\u3001\u4e88\u5099\u6226\u7565\u3001\u30aa\u30da\u30ec\u30fc\u30bf\u30fc\u306e\u624b\u9806\u3092\u6bd4\u8f03\u3057\u305f\u4e0a\u3067\u3001\u56fa\u5b9a\u5f0f\u304b\u53d6\u308a\u5916\u3057\u53ef\u80fd\u306a\u5f0f\u3092\u9078\u629e\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/li>\n<li>\u5b8c\u5168\u306a\u30a2\u30c3\u30d7\u30b9\u30c8\u30ea\u30fc\u30e0\/\u30c0\u30a6\u30f3\u30b9\u30c8\u30ea\u30fc\u30e0\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u3068\u306e\u8abf\u6574\u304a\u3088\u3073\u77ed\u7d61\u30ec\u30d3\u30e5\u30fc\u3092\u5b9f\u884c\u3057\u3001\u66f2\u7dda\u3084\u8a2d\u5b9a\u3092\u7ba1\u7406\u6587\u66f8\u3068\u3057\u3066\u4fdd\u6301\u3057\u307e\u3059\u3002.<\/li>\n<li>\u30d1\u30cd\u30eb\u30d3\u30eb\u30c0\u30fc\u306b\u30ea\u30ea\u30fc\u30b9\u3059\u308b\u524d\u306b\u3001\u6b63\u78ba\u306a\u88fd\u54c1\u30c9\u30ad\u30e5\u30e1\u30f3\u30c8\u3001\u691c\u67fb\u8a08\u753b\u3001\u5b9a\u671f\u691c\u67fb\u3001\u304a\u3088\u3073\u4ed8\u5c5e\u54c1\u306e\u4e92\u63db\u6027\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/li>\n<li>\u8abf\u9054\u306b\u95a2\u3059\u308b\u8b70\u8ad6\u306b\u3064\u3044\u3066\u306f\u3001\u6d59\u6c5fW9\u30b0\u30eb\u30fc\u30d7\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u6709\u9650\u516c\u53f8\uff082020\u5e74\u306b\u8a2d\u7acb\uff09\u306f\u4f4e\u96fb\u5727\u4fdd\u8b77\u88fd\u54c1\u3092\u8ca9\u58f2\u3057\u3066\u304a\u308a\u3001OEM\/ODM\u306e\u30b5\u30dd\u30fc\u30c8\u306b\u52a0\u3048\u3001\u8a66\u9a13\u304a\u3088\u3073\u691c\u67fb\u306e\u8abf\u6574\u3082\u884c\u3063\u3066\u3044\u307e\u3059\u3002\u4e00\u822c\u7684\u306a\u8a18\u8ff0\u306b\u983c\u308b\u306e\u3067\u306f\u306a\u304f\u3001W9\u306b\u69cb\u6210\u7279\u6709\u306e\u56f3\u9762\u3084\u8a3c\u62e0\u3092\u4f9d\u983c\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/li>\n<\/ol>\n<p>\u5b9f\u7528\u7684\u306a\u88fd\u54c1\u306e\u53c2\u8003\u306b\u3064\u3044\u3066\u306f\u3001\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002 <a href=\"https:\/\/w9-group.com\/ja\/product\/%e3%82%a8%e3%82%a2%e5%9b%9e%e8%b7%af%e9%81%ae%e6%96%ad%e5%99%a8-wew1-2000-acb-%e3%83%96%e3%83%ac%e3%83%bc%e3%82%ab-%e3%83%aa%e3%83%88%e3%83%a9%e3%82%af%e3%82%bf%e3%83%96%e3%83%ab%e3%82%bf%e3%82%a4\/\">WEW1 \u30a8\u30a2\u56de\u8def\u906e\u65ad\u5668\u88fd\u54c1\u30da\u30fc\u30b8<\/a>. \u898b\u7a4d\u3082\u308a\u3092\u627f\u8a8d\u3055\u308c\u305f\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u3001\u9069\u7528\u3055\u308c\u308b\u6a19\u6e96\u4ed5\u69d8\u3001\u304a\u3088\u3073\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u306e\u8a66\u9a13\u8981\u4ef6\u3068\u7d44\u307f\u5408\u308f\u305b\u308b\u3002.<\/p>\n<section id=\"faq\">\n<h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<h3>ACB\u3068MCCB\u306e\u9055\u3044\u306f\u4f55\u3067\u3059\u304b\uff1f<\/h3>\n<p>ACB\u906e\u65ad\u5668\u306f\u4e00\u822c\u7684\u306b\u9ad8\u96fb\u6d41\u306e\u914d\u96fb\u76e4\u304a\u3088\u3073\u9001\u96fb\u7dda\u306b\u4f7f\u7528\u3055\u308c\u3066\u304a\u308a\u3001\u4f4e\u96fb\u5727\u56de\u8def\u306b\u304a\u3051\u308b\u30a2\u30af\u30bb\u30b9\u53ef\u80fd\u306a\u4fdd\u8b77\u3001\u30b9\u30a4\u30c3\u30c1\u30f3\u30b0\u3001\u304a\u3088\u3073\u9023\u643a\u7528\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002MCCB\u306f\u901a\u5e38\u3088\u308a\u30b3\u30f3\u30d1\u30af\u30c8\u3067\u3042\u308a\u3001\u4e0b\u6d41\u56de\u8def\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u9069\u5207\u306a\u9078\u629e\u306f\u96fb\u6d41\u3001\u6545\u969c\u8ca0\u8377\u3001\u30b9\u30da\u30fc\u30b9\u3001\u9078\u629e\u6027\u3001\u304a\u3088\u3073\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306b\u5de6\u53f3\u3055\u308c\u308b\u3082\u306e\u3067\u3042\u308a\u3001\u5358\u7d14\u306a\u96fb\u6d41\u95be\u5024\u306b\u5de6\u53f3\u3055\u308c\u308b\u3082\u306e\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002.<\/p>\n<h3>\u30a8\u30a2\u56de\u8def\u30d6\u30ec\u30fc\u30ab\u306e\u30b5\u30a4\u30ba\u306f\u3069\u306e\u3088\u3046\u306b\u3057\u3066\u6c7a\u307e\u308a\u307e\u3059\u304b\uff1f<\/h3>\n<p>\u5b9f\u969b\u306e\u8ca0\u8377\u304b\u3089\u8a2d\u8a08\u96fb\u6d41\u3092\u8a08\u7b97\u3057\u3001\u5c0e\u7dda\u306e\u8010\u5727\u80fd\u529b\u3068\u5468\u56f2\u306e\u964d\u5727\u6761\u4ef6\u3092\u78ba\u8a8d\u3057\u3066\u304b\u3089\u3001\u5c06\u6765\u306e\u6545\u969c\u96fb\u6d41\u306b\u5bfe\u3057\u3066\u906e\u65ad\u304a\u3088\u3073\u77ed\u6642\u9593\u8010\u5727\u5b9a\u683c\u3092\u30c1\u30a7\u30c3\u30af\u3057\u307e\u3059\u3002\u8abf\u6574\u7814\u7a76\u3092\u901a\u3058\u3066\u9577\u671f\u3001\u77ed\u671f\u7684\u3001\u77ac\u6642\u306e\u6a5f\u80fd\u3068\u63a5\u5730\u6545\u969c\u6a5f\u80fd\u3092\u8a2d\u5b9a\u3057\u307e\u3059\u3002\u6700\u7d42\u7684\u306a\u8a2d\u5b9a\u306f\u8cac\u4efb\u3042\u308b\u96fb\u6c17\u6280\u5e2b\u306b\u3088\u308b\u78ba\u8a8d\u3092\u53d7\u3051\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n<h3>\u3044\u3064\u5f15\u304d\u51fa\u3057\u53ef\u80fd\u306aACB\u3092\u6307\u5b9a\u3059\u3079\u304d\u3067\u3059\u304b\uff1f<\/h3>\n<p>\u505c\u6b62\u6642\u9593\u304c\u77ed\u7e2e\u3055\u308c\u3001\u5b9a\u671f\u7684\u306a\u30c6\u30b9\u30c8\u304c\u5b9f\u65bd\u3055\u308c\u308b\u5834\u5408\u3001\u307e\u305f\u306f\u8fc5\u901f\u306a\u4ea4\u63db\u304c\u5fc5\u8981\u306a\u5834\u5408\u3001\u53d6\u308a\u5916\u3057\u53ef\u80fd\u306a\u69cb\u9020\u3092\u6307\u5b9a\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30e9\u30c3\u30af\u3001\u30b7\u30e3\u30c3\u30bf\u30fc\u3001\u30a4\u30f3\u30bf\u30fc\u30ed\u30c3\u30af\u3001\u30ea\u30d5\u30c8\u306e\u30b9\u30da\u30fc\u30b9\u3092\u78ba\u4fdd\u3057\u3001\u88fd\u9020\u5143\u306e\u624b\u9806\u306b\u3064\u3044\u3066\u64cd\u7e26\u58eb\u306b\u8aac\u660e\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u5c0f\u578b\u3067\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u5c11\u306a\u3044\u30dc\u30fc\u30c9\u306e\u5834\u5408\u3001\u56fa\u5b9a\u69cb\u9020\u306e\u65b9\u304c\u7dcf\u8cbb\u7528\u5bfe\u52b9\u679c\u304c\u9ad8\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002.<\/p>\n<h3>IEC 60947-2\u306f\u3001\u30d6\u30ec\u30fc\u30ab\u304cUL\u8a8d\u8a3c\u3092\u53d7\u3051\u3066\u3044\u308b\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u304b\uff1f<\/h3>\n<p>\u3044\u3044\u3048\u3002IEC 60947-2 \u3068 UL 1066 \u306f\u3001\u8a55\u4fa1\u304a\u3088\u3073\u30de\u30fc\u30ad\u30f3\u30b0\u30b7\u30b9\u30c6\u30e0\u304c\u7570\u306a\u308b\u88fd\u54c1\u898f\u683c\u3067\u3059\u3002\u5317\u7c73\u306e\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u3067\u306f\u3001\u8a72\u5f53\u3059\u308bUL\u306e\u8a3c\u660e\u66f8\u3068\u8a2d\u7f6e\u6761\u4ef6\u3092\u8981\u6c42\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u5358\u306a\u308bIEC\u306e\u5ba3\u8a00\u306f\u4ee3\u66ff\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002.<\/p>\n<h3>\u7523\u696d\u7528\u8cfc\u5165\u8005\u304c\u3069\u306e\u3088\u3046\u306a\u66f8\u985e\u3092\u8981\u6c42\u3059\u3079\u304d\u3067\u3059\u304b\uff1f<\/h3>\n<p>\u6b63\u78ba\u306a\u30d5\u30ec\u30fc\u30e0\u304a\u3088\u3073\u30c8\u30ea\u30c3\u30d7\u30e6\u30cb\u30c3\u30c8\u3001\u6642\u9593\u96fb\u6d41\u66f2\u7dda\u3001\u77ed\u7d61\u304a\u3088\u3073\u8010\u5727\u5b9a\u683c\u3001\u5bf8\u6cd5\u56f3\u9762\u304a\u3088\u3073\u914d\u7dda\u56f3\u3001\u4ed8\u5c5e\u54c1\u30ea\u30b9\u30c8\u3001\u65e5\u5e38\u691c\u67fb\u8a18\u9332\u3001\u8a2d\u7f6e\u624b\u9806\u304a\u3088\u3073\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30ac\u30a4\u30c9\u306e\u30c7\u30fc\u30bf\u30b7\u30fc\u30c8\u3092\u8acb\u6c42\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u306e\u8abf\u6574\u8abf\u67fb\u304a\u3088\u3073\u627f\u8a8d\u6e08\u307f\u8a2d\u5b9a\u3092\u79fb\u7ba1\u30d5\u30a1\u30a4\u30eb\u306b\u8ffd\u52a0\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n<\/section>\n<h2>\u53c2\u8003\u6587\u732e<\/h2>\n<ol>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/66277\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60947-2:2024, circuit-breaker public scope<\/a>. \u516c\u7684\u7bc4\u56f2\u304a\u3088\u3073\u30ac\u30a4\u30c0\u30f3\u30b9\u306f2026\u5e7410\u670815\u65e5\u306b\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32338\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61439-1:2020, assembly general rules<\/a>. \u516c\u7684\u7bc4\u56f2\u304a\u3088\u3073\u30ac\u30a4\u30c0\u30f3\u30b9\u306f2026\u5e7410\u670815\u65e5\u306b\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002.<\/li>\n<li><a href=\"https:\/\/electrical.theiet.org\/bs-7671\/\" rel=\"nofollow noopener\" target=\"_blank\">IET BS 7671 installation-standard resources; national adoption remains project-specific<\/a>. \u516c\u7684\u7bc4\u56f2\u304a\u3088\u3073\u30ac\u30a4\u30c0\u30f3\u30b9\u306f2026\u5e7410\u670815\u65e5\u306b\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002.<\/li>\n<\/ol>\n<p>Choose the ACB only when electrical duty, assembly evidence and the operating plan agree. Discuss the current schedule and site conditions alongside the WEW1 product documentation. Review the <a href=\"https:\/\/w9-group.com\/ja\/%e8%a3%bd%e5%93%81\/\">\u88fd\u54c1\u30e9\u30a4\u30f3\u30ca\u30c3\u30d7<\/a> with the intended destination-market requirements and retain the approved drawings, settings and maintenance procedure with the switchboard.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u7523\u696d\u7528\u30d1\u30cd\u30eb\u306eACB\u9078\u629e\u306b\u95a2\u3059\u308b\u5b9f\u7528\u7684\u306a\u30ac\u30a4\u30c9\u3067\u3001\u5b9a\u683c\u96fb\u5727\u3001\u8010\u969c\u5bb3\u6027\u3001\u9078\u629e\u6027\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3001\u57fa\u6e96\u3001\u304a\u3088\u3073\u7dcf\u8cbb\u7528\u3092\u7db2\u7f85\u3057\u3066\u3044\u307e\u3059\u3002.<\/p>","protected":false},"author":1,"featured_media":3745,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3506","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts\/3506","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/comments?post=3506"}],"version-history":[{"count":4,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts\/3506\/revisions"}],"predecessor-version":[{"id":4458,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts\/3506\/revisions\/4458"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/media\/3745"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/media?parent=3506"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/categories?post=3506"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/tags?post=3506"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}