{"id":3420,"date":"2026-04-07T09:00:00","date_gmt":"2026-04-07T01:00:00","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/blog\/benefits-of-lsig-circuit-breakers-for-electrical-systems\/"},"modified":"2026-10-20T10:43:22","modified_gmt":"2026-10-20T02:43:22","slug":"%e9%9b%bb%e6%b0%97%e3%82%b7%e3%82%b9%e3%83%86%e3%83%a0%e3%81%ab%e3%81%8a%e3%81%91%e3%82%8blsig%e5%9b%9e%e8%b7%af%e9%81%ae%e6%96%ad%e5%99%a8%e3%81%ae%e5%88%a9%e7%82%b9","status":"publish","type":"post","link":"https:\/\/w9-group.com\/ja\/blog\/benefits-of-lsig-circuit-breakers-for-electrical-systems\/","title":{"rendered":"\u73fe\u4ee3\u306e\u96fb\u6c17\u30b7\u30b9\u30c6\u30e0\u306b\u304a\u3051\u308bLsig\u906e\u65ad\u5668\u306e\u5229\u70b9\u3092\u63a2\u308b"},"content":{"rendered":"<p>LSIG functions give an engineer separate protection settings; they do not automatically make a system selective or safe at any setting. The benefit depends on the circuit study and the exact release supplied.<\/p>\n<p><a href=\"https:\/\/w9-group.com\/ja\/%e7%94%a3%e6%a5%ad%e7%94%a8%e8%a3%bd%e5%93%81\/mccb\/\">MCCB\u306e\u69cb\u6210<\/a> \u5fc5\u8981\u306a\u57fa\u6e96\u306b\u6cbf\u3063\u3066\u9078\u5b9a\u3055\u308c\u308b\u3079\u304d\u3067\u3059 <strong>\u4fdd\u8b77\u6a5f\u80fd<\/strong> \u305d\u3057\u3066\u3001\u96fb\u6c17\u7684\u306a\u4f7f\u7528\u91cf\u3082\u8a18\u9332\u3055\u308c\u3066\u3044\u307e\u3059\u3002.<\/p>\n<p>\u30ac\u30a4\u30c9\u3078\u306e <a href=\"https:\/\/w9-group.com\/ja\/blog\/%e7%ad%90%e4%bd%93%e5%bc%8f%e5%9b%9e%e8%b7%af%e9%81%ae%e6%96%ad%e5%99%a8%e3%81%ae%e5%9f%ba%e6%9c%ac%e3%82%ac%e3%82%a4%e3%83%89\/\">\u6210\u5f62\u30b1\u30fc\u30b9\u5f0f\u906e\u65ad\u5668<\/a> \u30d5\u30ec\u30fc\u30e0\u30b5\u30a4\u30ba\u3001\u8a55\u4fa1\u3001\u30c8\u30ea\u30c3\u30d7\u52d5\u4f5c\u306e\u9055\u3044\u3092\u8aac\u660e\u3057\u307e\u3059\u3002.<\/p>\n<p><img decoding=\"async\" alt=\"\u73fe\u4ee3\u306e\u96fb\u6c17\u30b7\u30b9\u30c6\u30e0\u306b\u304a\u3051\u308bLsig\u906e\u65ad\u5668\u306e\u5229\u70b9\u3092\u63a2\u308b\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/public\/img\/2025-11-02\/6157527852_0.png\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\"\/><img decoding=\"async\" alt=\"\u73fe\u4ee3\u306e\u96fb\u6c17\u30b7\u30b9\u30c6\u30e0\u306b\u304a\u3051\u308bLsig\u906e\u65ad\u5668\u306e\u5229\u70b9\u3092\u63a2\u308b\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/public\/img\/2025-11-02\/6157527852_1.png\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\"\/><img decoding=\"async\" alt=\"\u73fe\u4ee3\u306e\u96fb\u6c17\u30b7\u30b9\u30c6\u30e0\u306b\u304a\u3051\u308bLsig\u906e\u65ad\u5668\u306e\u5229\u70b9\u3092\u63a2\u308b\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/public\/img\/2025-11-02\/6157527852_2.png\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\"\/><img decoding=\"async\" alt=\"2025\u5e74\u306e\u30d9\u30b9\u30c8\u30b5\u30fc\u30ad\u30c3\u30c8\u30d6\u30ec\u30fc\u30ab\u30fc\u306e\u30c8\u30ec\u30f3\u30c9\u3092\u5c02\u9580\u7684\u306a\u8cfc\u8cb7\u6226\u7565\u3067\u30ca\u30d3\u30b2\u30fc\u30c8\u3059\u308b\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/public\/img\/2025-06-24\/43aaa6976548d1056e6371b1d38e4673.png\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\"\/><\/p>\n<h2>Test and govern the settings<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u30b9\u30c6\u30fc\u30b8<\/th>\n<th>\u4fdd\u6301\u3059\u3079\u304d\u8a3c\u62e0<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Study<\/td>\n<td>Source assumptions and coordinated curves<\/td>\n<\/tr>\n<tr>\n<td>Configuration<\/td>\n<td>Exact release, sensor and neutral arrangement<\/td>\n<\/tr>\n<tr>\n<td>Test<\/td>\n<td>Manufacturer-approved method and results<\/td>\n<\/tr>\n<tr>\n<td>\u5f15\u304d\u6e21\u3057<\/td>\n<td>As-left settings and authorised revision<\/td>\n<\/tr>\n<tr>\n<td>Change<\/td>\n<td>Reassessment and updated test record<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>IEC 60947-2 product declarations do not approve an arbitrary delay or sensing arrangement. Follow the release&#8217;s test instructions, recognising the different scope of primary and secondary injection. Include test equipment, engineering, spares and inspection in lifecycle cost. Ask W9 for exact LSIG release documents rather than a broad claim of advanced protection.<\/p>\n<p>\u300cuse\u300d\u3092 <a href=\"https:\/\/w9-group.com\/ja\/blog\/mccb%e3%81%ae%e6%8a%80%e8%a1%93%e8%a6%81%e4%bb%b6\/\">MCCB\u306e\u6280\u8853\u8981\u4ef6<\/a> \u4ed5\u69d8\u3092\u6ce8\u6587\u30b3\u30fc\u30c9\u3068\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u30d5\u30a1\u30a4\u30eb\u3068\u6bd4\u8f03\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n<p><img decoding=\"async\" alt=\"\u30d9\u30b9\u30c8\u30b5\u30fc\u30de\u30eb\u78c1\u6c17\u906e\u65ad\u5668\u306e\u672a\u6765\uff1a\u4eca\u5f8c\u306e\u9032\u6b69\u3068\u9769\u65b0\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/public\/img\/2025-08-03\/f01078da14abbe94e7960951044fc6c8.png\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\"\/><img decoding=\"async\" alt=\"Top Industry Standards: 7 Compelling Reasons to Choose the Best Molded Circuit Breaker\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/public\/img\/2025-06-16\/01abe0103d48dd70f99ff705157521bc.png\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\"\/><img decoding=\"async\" alt=\"\u30d9\u30b9\u30c8\u30a8\u30a2\u30d6\u30ec\u30fc\u30ab\u56de\u8def\u906e\u65ad\u5668\u306e\u6027\u80fd\u3092\u5f15\u304d\u51fa\u3059\u305f\u3081\u306e\u4ed5\u69d8\u3068\u8a2d\u7f6e\u30ac\u30a4\u30c9\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/public\/img\/2025-06-30\/ceb4c5500c21b4faef58c7b85830ddbc.png\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\"\/><img decoding=\"async\" alt=\"Navigating Import and Export Certifications for Best Circuit Breakers in Global Trade\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/public\/img\/2025-07-14\/16bdc43ddb79561afd45d4b648669198.png\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\"\/><img decoding=\"async\" alt=\"The Future of Electronic MCCB Innovations Driving Energy Efficiency and Safety\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/public\/img\/2025-09-07\/37f302927703c1b27002a26acfdd94e8.png\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\"\/><\/p>\n<h2>Assign each LSIG function a design job<\/h2>\n<p><strong>Long-time pickup<\/strong> and delay protect the sustained-load region within the conductor limit. Short-time delay can support downstream discrimination but increases exposure while a fault persists. Instantaneous pickup must be reviewed against permitted inrush and fault-disconnection needs. Ground-fault sensing must match the earthing and neutral arrangement.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u6a5f\u80fd<\/th>\n<th>\u30c7\u30b6\u30a4\u30f3\u306e\u30a4\u30f3\u30d7\u30c3\u30c8<\/th>\n<th>\u78ba\u8a8d<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>L<\/td>\n<td>Load and conductor ampacity<\/td>\n<td>Pickup and overload curve<\/td>\n<\/tr>\n<tr>\n<td>S<\/td>\n<td>Downstream protection<\/td>\n<td>Selectivity and withstand<\/td>\n<\/tr>\n<tr>\n<td>I<\/td>\n<td>Inrush and fault level<\/td>\n<td>High-current response<\/td>\n<\/tr>\n<tr>\n<td>G<\/td>\n<td>Earthing and sensing<\/td>\n<td>Pickup, delay and neutral path<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The resulting settings need authorisation, commissioning and change control. Do not disable a function to obtain a cleaner curve without reviewing the resulting protection gap. An LSIG label does not establish a 30 mA residual-current function or a communication interface.<\/p>\n<section id=\"faq\">\n<h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<h3>What does LSIG stand for?<\/h3>\n<p>Long-time, short-time, instantaneous and ground-fault protection. Confirm which functions and setting ranges are present in the exact release.<\/p>\n<h3>Does LSIG guarantee selective coordination?<\/h3>\n<p>No. Selectivity depends on the actual devices, settings and fault levels. Complete the <strong>\u8abf\u6574\u7814\u7a76<\/strong> and verify the approved settings.<\/p>\n<h3>Is G the same as an RCD&#8217;s additional shock protection?<\/h3>\n<p>Not automatically. Sensitivity, waveform response and sensing arrangement can differ substantially. Verify the required function separately.<\/p>\n<h3>Can settings be changed whenever loads change?<\/h3>\n<p>Changes require an approved protection review and updated records. Re-test as required and preserve conductor and equipment protection.<\/p>\n<\/section>\n<h2>\u53c2\u8003\u6587\u732e<\/h2>\n<ul>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/66277\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60947-2:2024 \u2014 \u56de\u8def\u65ad\u958b\u5668\u88fd\u54c1\u306e\u7bc4\u56f2<\/a>.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32338\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61439-1:2020 \u2014 \u4f4e\u96fb\u5727\u30a2\u30bb\u30f3\u30d6\u30ea\u306e\u4e00\u822c\u898f\u5247<\/a>.<\/li>\n<li><a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\" rel=\"nofollow noopener\" target=\"_blank\">NFPA 70 \u2014 \u7c73\u56fd\u306e\u8a2d\u7f6e\u57fa\u6e96\u306e\u958b\u767a\u3068\u7bc4\u56f2<\/a>.<\/li>\n<\/ul>\n<p>\u63d0\u6848\u3055\u308c\u305f\u69cb\u6210\u3092\u78ba\u8a8d\u3059\u308b\u306b\u306f\u3001, <a href=\"https:\/\/w9-group.com\/ja\/contact-us\/\">W9\u30b0\u30eb\u30fc\u30d7\u3078\u306e\u304a\u554f\u3044\u5408\u308f\u305b<\/a> \u8ca0\u8377\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u306b\u3088\u308a\u5229\u7528\u53ef\u80fd <strong>\u6545\u969c\u96fb\u6d41<\/strong> \u305d\u3057\u3066\u3001\u76ee\u7684\u5730\u5e02\u5834\u306e\u8981\u4ef6\u3002.<\/p>","protected":false},"excerpt":{"rendered":"<p>These days, the electrical world kind of demands fresh, reliable solutions to keep things safe and running smoothly. One cool option that&#8217;s been<\/p>","protected":false},"author":1,"featured_media":3794,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3420","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts\/3420","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/comments?post=3420"}],"version-history":[{"count":5,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts\/3420\/revisions"}],"predecessor-version":[{"id":4693,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts\/3420\/revisions\/4693"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/media\/3794"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/media?parent=3420"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/categories?post=3420"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/tags?post=3420"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}