{"id":3409,"date":"2026-03-24T09:00:00","date_gmt":"2026-03-24T01:00:00","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/blog\/advanced-protection-of-800v-mccb-electronic-jcr3hm-rcd-with-built-in-lsig-trip-unit\/"},"modified":"2026-10-20T10:37:31","modified_gmt":"2026-10-20T02:37:31","slug":"800v-mccb-%e9%9b%bb%e5%ad%90%e5%bc%8f-jcr3hm-rcd-%e3%81%ae%e9%ab%98%e5%ba%a6%e3%81%aa%e4%bf%9d%e8%ad%b7%e6%a9%9f%e8%83%bd%e3%80%81%e5%86%85%e8%94%b5%e3%81%ae-lsig-%e3%83%88%e3%83%aa%e3%83%83%e3%83%97","status":"publish","type":"post","link":"https:\/\/w9-group.com\/ja\/blog\/advanced-protection-of-800v-mccb-electronic-jcr3hm-rcd-with-built-in-lsig-trip-unit\/","title":{"rendered":"JCR3HM RCCB vs LSIG MCCB: \u4fdd\u8b77\u6a5f\u80fd\u3068\u5b9a\u683c\u5236\u9650"},"content":{"rendered":"<p>The older title combines two different device descriptions: an 800 V electronic MCCB with LSIG and the JCR3HM RCD. They must not be treated as one product. The current JCR3HM listing identifies an <a href=\"https:\/\/w9-group.com\/ja\/%e5%9b%9e%e8%b7%af%e4%bf%9d%e8%ad%b7%e8%a3%bd%e5%93%81\/rccb%e5%9b%9e%e8%b7%af%e4%bf%9d%e8%ad%b7%e8%a3%bd%e5%93%81\/\">RCCB<\/a> \u6b8b\u7559\u96fb\u6d41\u4fdd\u8b77\u7528\u3067\u3042\u308a\u3001\u5225\u9014\u5354\u8abf\u3055\u308c\u305f\u904e\u96fb\u6d41\u4fdd\u8b77\u306e\u8a2d\u7f6e\u304c\u6c42\u3081\u3089\u308c\u308b\u3002.<\/p>\n<p>The <strong>JCR3HM RCCB<\/strong> table lists 2P\/4P, Type A or AC, 30\/100\/300 mA options and current choices from 25 to 100 A. It lists 230\/240 V for 2P and 400\/415 V for 4P. It does not establish an 800 V LSIG MCCB rating.<\/p>\n<h2>What JCR3HM does<\/h2>\n<p>It detects residual current within the selected waveform and sensitivity scope. An RCCB under IEC 61008-1 has no <strong>integral overcurrent protection<\/strong>. Its current-carrying rating must therefore be coordinated with the circuit&#8217;s MCB or fuse and the manufacturer&#8217;s fault-protection arrangement.<\/p>\n<p>Choose waveform type from the connected load and sensitivity from the protection objective and installation rules. A 300 mA setting cannot simply replace required 30 mA additional protection to avoid trips.<\/p>\n<p>Review the difference between <a href=\"https:\/\/w9-group.com\/ja\/blog\/what-is-the-difference-between-rcbo-and-rccb-2\/\">RCBO\u304a\u3088\u3073RCCB\u306e\u4fdd\u8b77<\/a> before allocating overload and residual-current functions.<\/p>\n<h2>What an LSIG MCCB does<\/h2>\n<p>An <strong>LSIG MCCB<\/strong> provides declared long-time, short-time, instantaneous and ground-fault functions. Its ground-fault function is not automatically equivalent to the high-sensitivity residual-current function required on a final circuit. Voltage, fault duty and sensing arrangements must come from its own exact model table.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u30d5\u30a3\u30fc\u30eb\u30c9<\/th>\n<th>JCR3HM listing<\/th>\n<th>Electronic LSIG MCCB<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u88fd\u54c1\u30ab\u30c6\u30b4\u30ea\u30fc<\/td>\n<td>RCCB<\/td>\n<td>MCCB with specified electronic release<\/td>\n<\/tr>\n<tr>\n<td>\u904e\u96fb\u6d41\u4fdd\u8b77<\/td>\n<td>Separate coordinated device required<\/td>\n<td>Declared L\/S\/I functions<\/td>\n<\/tr>\n<tr>\n<td>Leakage or earth-fault function<\/td>\n<td>Selected residual-current type and sensitivity<\/td>\n<td>Ground-fault function within release scope<\/td>\n<\/tr>\n<tr>\n<td>Voltage<\/td>\n<td>Listed 2P and 4P values<\/td>\n<td>Exact MCCB rating table required<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u30ac\u30a4\u30c9\u3078\u306e <a href=\"https:\/\/w9-group.com\/ja\/blog\/%e9%9b%bb%e6%b0%97%e5%ae%89%e5%85%a8%e3%81%ab%e3%81%8a%e3%81%91%e3%82%8brccb%e3%81%ae%e9%87%8d%e8%a6%81%e6%80%a7%ef%bc%9a%e4%ba%ba%e5%91%bd%e3%81%a8%e8%b2%a1%e7%94%a3%e3%81%ae%e4%bf%9d%e8%ad%b7\/\">\u6b8b\u7559\u96fb\u6d41\u4fdd\u8b77<\/a> describes the installation conditions that a device label alone cannot establish.<\/p>\n<p><img decoding=\"async\" alt=\"800v Mccb \u96fb\u5b50\u30bf\u30a4\u30d7\u3001Lsig \u30c8\u30ea\u30c3\u30d7\u30e6\u30cb\u30c3\u30c8\u5185\u8535\u3002jpg\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/upload\/p\/1205\/image_product\/2024-09\/3-pole-acb-drawer-type-fixed-type.jpg\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\" width=\"300\"\/><\/p>\n<h2>Keep the two specifications separate<\/h2>\n<p>For JCR3HM, request poles, current, Type A or AC, <strong>residual-current sensitivity<\/strong> and coordination evidence. For an 800 V MCCB requirement, request a different exact product code with explicit AC or DC operating voltage and fault ratings. Neither product&#8217;s name supplies the other&#8217;s functions.<\/p>\n<table>\n<thead>\n<tr>\n<th>Order<\/th>\n<th>Essential evidence<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>JCR3HM RCCB<\/td>\n<td>RCCB datasheet, wiring and overcurrent coordination<\/td>\n<\/tr>\n<tr>\n<td>800 V MCCB<\/td>\n<td>Exact voltage and fault-duty table, trip curves and connections<\/td>\n<\/tr>\n<tr>\n<td>Complete panel<\/td>\n<td>Assembly verification and installation design<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Installation and procurement checks<\/h2>\n<p>Neutral routing, earthing and test procedures remain important for the RCCB. Use the declared test method and a suitable residual-current tester. IEC 61008-1 and IEC 60947-2 have different product scopes; listing both does not combine two device categories.<\/p>\n<p>Ask W9 Group to confirm the exact required product before quotation. Keep the RCCB and MCCB schedules separate so a misleading legacy title cannot become a purchasing instruction.<\/p>\n<section id=\"faq\">\n<h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<h3>Is JCR3HM an 800 V LSIG MCCB?<\/h3>\n<p>No. The reviewed current listing identifies an RCCB with separate overcurrent protection required. It does not establish that combined description.<\/p>\n<h3>Does JCR3HM provide overload protection by itself?<\/h3>\n<p>No. Its RCCB function requires a coordinated MCB or fuse for overload and short-circuit protection.<\/p>\n<h3>Is an MCCB ground-fault function the same as a 30 mA RCD?<\/h3>\n<p>Not automatically. Sensitivity, waveform response, sensing and intended protection differ. Verify the exact functions required by the installation.<\/p>\n<h3>How should an 800 V requirement be quoted?<\/h3>\n<p>Specify a separate exact MCCB with the required AC or DC voltage, fault duty, poles and trip functions. Do not infer it from the JCR3HM name.<\/p>\n<\/section>\n<h2>\u53c2\u8003\u6587\u732e<\/h2>\n<ul>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/67980\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61008-1:2024 \u2014 RCCBs without integral overcurrent protection<\/a>.<\/li>\n<li><a href=\"https:\/\/electrical.theiet.org\/wiring-matters\/years\/2019\/77-september-2019\/which-rcd-type\/\" rel=\"nofollow noopener\" target=\"_blank\">IET \u2014 \u3069\u306e\u30bf\u30a4\u30d7\u306eRCD\u3067\u3059\u304b\uff1f<\/a>.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/24656\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60364-6:2016 \u2014 \u8a2d\u7f6e\u78ba\u8a8d<\/a>.<\/li>\n<\/ul>\n<p>For waveform and pole selection, <a href=\"https:\/\/w9-group.com\/ja\/contact-us\/\">W9\u30b0\u30eb\u30fc\u30d7\u3078\u306e\u304a\u554f\u3044\u5408\u308f\u305b<\/a> with the circuit topology, load equipment and destination-market rules.<\/p>","protected":false},"excerpt":{"rendered":"<p>800V JCR3HM RCD MCCB\u3092\u5099\u3048\u305f\u9ad8\u5ea6\u306a\u4fdd\u8b77\u3092\u3054\u5229\u7528\u304f\u3060\u3055\u3044\u3002\u6700\u5927\u5b89\u5168\u6027\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u5185\u8535\u306eLSIG\u30c8\u30ea\u30c3\u30d7\u30e6\u30cb\u30c3\u30c8\u304c\u642d\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u96fb\u6c17\u8a2d\u5099\u306b\u95a2\u3059\u308b\u30cb\u30fc\u30ba\u306b\u6700\u9069\u306a\u88fd\u54c1\u3092\u304a\u63a2\u3057\u304f\u3060\u3055\u3044\u3002<\/p>","protected":false},"author":1,"featured_media":3801,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3409","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts\/3409","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/comments?post=3409"}],"version-history":[{"count":4,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts\/3409\/revisions"}],"predecessor-version":[{"id":4675,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts\/3409\/revisions\/4675"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/media\/3801"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/media?parent=3409"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/categories?post=3409"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/tags?post=3409"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}