{"id":1394,"date":"2026-01-01T09:00:00","date_gmt":"2026-01-01T01:00:00","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/blog\/jc3le-2p-rcbos-tiny-guardian-stops-shocks-fires-2\/"},"modified":"2026-10-24T14:18:31","modified_gmt":"2026-10-24T06:18:31","slug":"jc3le-2p-rcbos-tiny-guardian-stops-shocks-fires-2","status":"publish","type":"post","link":"https:\/\/w9-group.com\/ja\/blog\/jc3le-2p-rcbos-tiny-guardian-stops-shocks-fires-2\/","title":{"rendered":"JC3LE-2P RCBO: 6 kA Ratings and Circuit Selection"},"content":{"rendered":"<p>A two-pole <a href=\"https:\/\/w9-group.com\/ja\/%e5%9b%9e%e8%b7%af%e4%bf%9d%e8%ad%b7%e8%a3%bd%e5%93%81\/rcbo\/\">RCBO<\/a> order can look complete while omitting the residual-current waveform and fault duty. For JC3LE-2P, those details matter more than a broad promise to prevent shocks or fires: the protective functions must match the circuit and its installation rules.<\/p>\n<p>Summary: The JC3LE-2P is an RCBO: it combines overcurrent protection and <strong>\u6b8b\u7559\u96fb\u6d41\u4fdd\u8b77<\/strong> in one two-pole device. Published product information describes 6-63 A choices, B or C curves, a Type A residual-current option in the current technical table and a 6 kA short-circuit rating; verify the exact order code before relying on any value. Start with circuit current, waveform, sensitivity, poles, fault level and local installation rules, then document the test-button and commissioning checks.<\/p>\n<h2>JC3LE-2P Protection Scope<\/h2>\n<p>An RCBO is selected by the protection boundary it must cover, not by the label alone. The MCB element addresses overload and short circuit; the residual-current element compares current paths and trips when the declared residual current is exceeded.<\/p>\n<h2>JC3LE-2P Protection Functions<\/h2>\n<p>The published JC3LE-2P description identifies double-pole switching, a contact indicator and selectable B\/C curves. The ordered <strong>\u6b8b\u7559\u96fb\u6d41\u578b<\/strong> must be matched to the connected load and the local code. A 30 mA, 100 mA or 300 mA sensitivity is a project decision; do not infer shock or fire protection from a generic RCBO name.<\/p>\n<h3>Installation boundary<\/h3>\n<p>Route the neutral through the sensing path specified by the wiring diagram, torque terminals to the current instructions, and verify line\/load orientation. Test the device with the required instrument and record the result; a front test button does not replace the complete commissioning procedure.<\/p>\n<p>The <a href=\"https:\/\/w9-group.com\/ja\/blog\/4-pole-rcbo-with-alarm-6ka-safety-switch-circuit-breaker-jcb2le\/\">4\u6975RCBO\u30ac\u30a4\u30c9<\/a> \u30a2\u30e9\u30fc\u30e0\u4fe1\u53f7\u3001\u8ca0\u8377\u96fb\u6d41\u3001\u304a\u3088\u3073 <strong>\u7834\u58ca\u80fd\u529b<\/strong> \u5225\u9014\u78ba\u8a8d\u304c\u5fc5\u8981\u3067\u3059\u3002.<\/p>\n<h2>RCBO Specification Checks<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u6c7a\u5b9a\u6b21\u5143<\/th>\n<th>\u78ba\u8a8d\u3059\u3079\u304d\u3053\u3068<\/th>\n<th>\u306a\u305c\u91cd\u8981\u306a\u306e\u304b<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Overcurrent<\/td>\n<td>Rated current and B\/C curve<\/td>\n<td>Matches conductor ampacity and inrush<\/td>\n<\/tr>\n<tr>\n<td>\u6b8b\u7559\u96fb\u6d41<\/td>\n<td>Type AC or Type A; I\u0394n<\/td>\n<td>Matches waveform and protection objective<\/td>\n<\/tr>\n<tr>\n<td>\u6545\u969c\u6642\u306e\u7fa9\u52d9<\/td>\n<td>Declared breaking capacity<\/td>\n<td>Must exceed prospective fault current<\/td>\n<\/tr>\n<tr>\n<td>Switching<\/td>\n<td>Two-pole neutral isolation<\/td>\n<td>Supports the specified isolation method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Reading the current JC3LE-2P listing<\/h2>\n<p>The current W9 product table lists 6 kA at 230\/240 V, 50\/60 Hz, 6\u201363 A options, 30\/100\/300 mA sensitivity and B or C overcurrent curves. Its waveform table identifies Type A. These are separate specification fields: a 6 kA short-circuit rating does not describe residual-current sensitivity, and a B curve does not make the device a Type B RCD.<\/p>\n<p>An order should identify all these fields together. For example, a circuit requiring additional protection cannot adopt a higher residual-current threshold simply to stop unwanted operation. Investigate standing leakage, shared neutrals and connected equipment, then apply the destination rules and manufacturer instructions. Do not use this article as a live-work procedure.<\/p>\n<p>\u6bd4\u8f03\u306e\u4ed5\u65b9 <a href=\"https:\/\/w9-group.com\/ja\/blog\/what-is-the-difference-between-rcbo-and-rccb-2\/\">RCBO\u304a\u3088\u3073RCCB\u306e\u4fdd\u8b77<\/a> \u30a4\u30f3\u30c6\u30b0\u30ec\u30fc\u30c8\u578b\u904e\u96fb\u6d41\u4fdd\u8b77\u3068\u6b8b\u7559\u96fb\u6d41\u691c\u51fa\u3092\u533a\u5225\u3059\u308b\u306e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002.<\/p>\n<h2>RCBO Application Requirements<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u7533\u8acb<\/th>\n<th>Check before release<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Lighting and socket circuits<\/td>\n<td>Load current, curve and 30 mA requirement<\/td>\n<\/tr>\n<tr>\n<td>Motor or refrigeration branch<\/td>\n<td>Starting current and nuisance-trip margin<\/td>\n<\/tr>\n<tr>\n<td>\u96fb\u5b50\u6a5f\u5668\u7528\u8ca0\u8377<\/td>\n<td>Residual-current waveform and Type A need<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u57fa\u6e96\u3068\u30b3\u30f3\u30d7\u30e9\u30a4\u30a2\u30f3\u30b9<\/h2>\n<p>IEC 61009-1 is the product standard for RCBOs; IEC 61008-1 covers RCCBs without integral overcurrent protection. IEC 60364-4-41 addresses protection against electric shock at installation level. A standard reference is not a certificate for every model, so request the exact declaration, test scope and wiring diagram for the supplied device.<\/p>\n<h2>\u9078\u5b9a\u304a\u3088\u3073\u8a66\u904b\u8ee2\u30c1\u30a7\u30c3\u30af\u30ea\u30b9\u30c8<\/h2>\n<ol>\n<li>\u8a18\u9332\u96fb\u5727\u3001\u96fb\u6d41\u3001\u30dd\u30fc\u30eb\u6570\u3001\u8ca0\u8377\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u3001\u304a\u3088\u3073\u5c06\u6765\u7684\u306a\u6545\u969c\u96fb\u6d41\u3002.<\/li>\n<li>\u627f\u8a8d\u3055\u308c\u305f\u56f3\u9762\u3068\u6a19\u6e96\u4ed5\u69d8\u306b\u3001\u6b63\u78ba\u306a\u30e2\u30c7\u30eb\u3068\u4ed8\u5c5e\u54c1\u3092\u4e00\u81f4\u3055\u305b\u307e\u3059\u3002.<\/li>\n<li>\u30ec\u30d3\u30e5\u30fc\u306e\u8abf\u6574\u3001\u8a31\u53ef\u306e\u53d6\u5f97\u3001\u6e29\u5ea6\u304a\u3088\u3073\u4fdd\u7ba1\u74b0\u5883\u306e\u78ba\u8a8d\u3092\u884c\u3046\u3002.<\/li>\n<li>\u7bc4\u56f2\u5185\u3067\u5ba3\u8a00\u66f8\u3001\u8a66\u9a13\u8cc7\u6599\u3001\u304a\u3088\u3073\u8a2d\u7f6e\u624b\u9806\u66f8\u306e\u63d0\u51fa\u3092\u6c42\u3081\u307e\u3059\u3002.<\/li>\n<li>\u5c0e\u5165\u6642\u306e\u8a18\u9332\u8a2d\u5b9a\u3001\u30c8\u30eb\u30af\u5024\u3001\u6a5f\u80fd\u30c6\u30b9\u30c8\u7d50\u679c\u3092\u8a18\u9332\u3057\u307e\u3059\u3002.<\/li>\n<\/ol>\n<h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<h3>Is JC3LE-2P a 10 kA RCBO?<\/h3>\n<p>The current product table lists 6 kA, not 10 kA. Use the delivered order code and marking to confirm the rating at the actual circuit voltage; do not borrow a rating from a different JC3LE model.<\/p>\n<h3>Does the B curve mean Type B residual-current protection?<\/h3>\n<p>No. B and C curves describe overcurrent operation, while Type A describes residual-<strong>current waveform<\/strong> capability. Both fields must be specified independently.<\/p>\n<h3>Can a 300 mA option replace a required 30 mA device?<\/h3>\n<p>Not merely to avoid tripping. Sensitivity must satisfy the circuit&#8217;s protection objective and local installation rules; a higher threshold is not an equivalent substitute for required additional protection.<\/p>\n<h3>Why does an RCBO trip with its load disconnected?<\/h3>\n<p>A shared or incorrectly routed neutral, wiring defect or device problem may remain even when the appliance is removed. A competent electrician should isolate and test the circuit rather than repeatedly reset it.<\/p>\n<h2>\u53c2\u8003\u6587\u732e<\/h2>\n<ul>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/67981\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61009-1:2024 \u2014 RCBO \u306e\u4e00\u822c\u8981\u4ef6<\/a>.<\/li>\n<li><a href=\"https:\/\/electrical.theiet.org\/wiring-matters\/years\/2019\/77-september-2019\/which-rcd-type\/\" rel=\"nofollow noopener\" target=\"_blank\">IET \u2014 \u3069\u306e\u30bf\u30a4\u30d7\u306eRCD\u3067\u3059\u304b\uff1f<\/a>.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/24656\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60364-6:2016 \u2014 \u8a2d\u7f6e\u78ba\u8a8d<\/a>.<\/li>\n<\/ul>\n<p>Review the JC3LE-2P information with the current datasheet and contact W9 Group with the circuit schedule, fault level and destination-market requirements.<\/p>\n<p>\u56de\u8def\u30ec\u30d9\u30eb\u3067\u306e\u9078\u629e\u306b\u3064\u3044\u3066\u306f\u3001, <a href=\"https:\/\/w9-group.com\/ja\/contact-us\/\">W9\u30b0\u30eb\u30fc\u30d7\u3078\u306e\u304a\u554f\u3044\u5408\u308f\u305b<\/a> \u56de\u8def\u56f3\u3001\u8ca0\u8377\u6ce2\u5f62\u3001\u63a5\u5730\u914d\u7f6e\u3001\u304a\u3088\u3073\u9069\u7528\u53ef\u80fd\u306a\u8a2d\u7f6e\u898f\u5247\u3092\u8003\u616e\u3057\u3066\u3002.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u81ea\u5b85\u306e\u96fb\u6c17\u914d\u7dda\u306b\u57cb\u3081\u8fbc\u307e\u308c\u305f\u5c0f\u3055\u306a\u30b5\u30a4\u30ec\u30f3\u30c8\u30b9\u30fc\u30d1\u30fc\u30d2\u30fc\u30ed\u30fc\u3092\u60f3\u50cf\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002\u305d\u306e\u4f7f\u547d\u306f\u3001\u96fb\u6c17\u904e\u8ca0\u8377\u3084\u77ed\u7d61\u306b\u3088\u308b\u58ca\u6ec5\u7684\u306a\u706b\u707d\u3084\u3001\u5730\u7d61\u306b\u3088\u308b\u5371\u967a\u306a\u96fb\u6c17\u30b7\u30e7\u30c3\u30af\u3068\u3044\u3046\u3001\u6700\u3082\u6050\u308d\u3057\u3044\u5bb6\u5ead\u306e\u60aa\u5f79\u306e2\u3064\u3092\u9632\u3050\u3053\u3068\u3067\u3059\u3002JC3LE-2P RCBO\uff08\u6b8b\u7559\u96fb\u6d41\u906e\u65ad\u5668\uff09 (RCBO) (\u54c1\u756a\uff1aJC3LE-2P) \u3092\u3054\u6848\u5185\u3044\u305f\u3057\u307e\u3059\u3002<\/p>","protected":false},"author":1,"featured_media":4899,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1394","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts\/1394","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/comments?post=1394"}],"version-history":[{"count":6,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts\/1394\/revisions"}],"predecessor-version":[{"id":4772,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/posts\/1394\/revisions\/4772"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/media\/4899"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/media?parent=1394"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/categories?post=1394"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/w9-group.com\/ja\/wp-json\/wp\/v2\/tags?post=1394"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}