{"id":2927,"date":"2026-07-30T11:46:42","date_gmt":"2026-07-30T03:46:42","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/jc3be-dc-dc-miniature-circuit-breaker\/"},"modified":"2026-07-30T11:46:49","modified_gmt":"2026-07-30T03:46:49","slug":"jc3be-dc-dc-miniature-circuit-breaker","status":"publish","type":"product","link":"https:\/\/w9-group.com\/fa\/product\/jc3be-dc-dc-miniature-circuit-breaker\/","title":{"rendered":"JC3BE-DC DC Miniature Circuit Breaker 10kA"},"content":{"rendered":"<h2>Introduction<\/h2>\n<p>JC3BE-DC miniature DC circuit breaker is designed for solar \/ photovoltaic PV system, energy storage and other direct current DC applications.They are mainly placed between batteries and hybrid inverters.<br \/>JC3BE-DC DC circuit breaker is a protective device equipped with both a thermal that is available in 1 pole ,2pole, 3 pole and 4 pole versions. The switching capacity is 10kA according to IEC\/EN 60947-2. The DC rated voltage is 250V per pole, rated voltage up to 1000V DC.<br \/>JC3BE-DC circuit breaker is available with rated currents of 2A to 63A.<br \/>JC3BE-DC circuit breaker offer new features, better connection, superior performance and increased levels of security. Its breaking capacity is up to 10kA.<br \/>JC3BE-DC dc circuit breaker can be locked (by a padlocking device) in OFF position as a safety measure for removal of the PV inverter<br \/>Since a fault current can flow in the reverse direction to the operating current, the JC3BE-DC Circuit breaker can detect and protect against any bidirectional current. To ensure the safety of the installation, it is necessary, depending on the various types of application, to combine the circuit breaker with:<br \/>\u2022 a residual current device at the AC end,<br \/>\u2022 a fault passage detector (insulation monitoring device) at the DC end<br \/>\u2022 an earth protection circuit breaker at the DC end<br \/>In all cases, fast action on site will be required to clear the fault (protection not ensured in the event of a double fault). The circuit breaker is: delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors<\/p>\n<h2>The most important features:<\/h2>\n<p>\u00a0JC3BE-DC\u00a0circuit breaker for DC applications<\/p>\n<p>\u00a0Non-polarity, Easy wiring<\/p>\n<p>\u00a0Rated voltage up to 1000V DC<\/p>\n<p>\u00a0Rated switching capacity 10\u00a0kA according to IEC\/EN 60947-2<\/p>\n<p>\u00a0Insulation voltage Ui 1000V<\/p>\n<p>\u00a0Rated impulse withstand voltage\u00a0Uimp (V) 4000V<\/p>\n<p>\u00a0Back-up fuse with high selectivity, thanks to low let-through energy<\/p>\n<p>\u00a0Contact position indicator red \u2013 green<\/p>\n<p>\u00a0Rated currents up to 63A<\/p>\n<p>\u00a0Available in1 Pole, 2 Pole, 3 Pole and 4 Pole<\/p>\n<p>\u00a01 Pole=250Vdc, 2 Pole=500Vdc, 3 Pole=750Vdc, 4 Pole=1000Vdc<\/p>\n<p>\u00a0Compatible with Cable PIN or U type standard\u00a0busbars<\/p>\n<p>\u00a0Designed for Solar, PV, energy storage and other DC applications<\/p>\n<p>\u00a0The housing is made of high flame-retardant PA nylon, effectively preventing accidental fires.<\/p>\n<h2>Technical Data:<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\">\n<p>Standard<\/p>\n<\/td>\n<td>\n<p>IEC\/EN 60947-2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Electrical features<\/p>\n<\/td>\n<td>\n<p>Rated current In(A)<\/p>\n<\/td>\n<td>\n<p>2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Rated voltage Ue(V)<\/p>\n<\/td>\n<td>\n<p>1P:DC250V, 2P:DC500V, 3P:DC750V, 4P:DC1000V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Insulation voltage Ui(V)<\/p>\n<\/td>\n<td>\n<p>1000V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Rated impulse withstand voltage Uimp(V)<\/p>\n<\/td>\n<td>\n<p>4000V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Rated breaking capacity<\/p>\n<\/td>\n<td>\n<p>10KA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Rated impulse withstand voltage (1.2\/50) Uimp (V)<\/p>\n<\/td>\n<td>\n<p>4000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Pollution degree<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Thermo-magnetic release characteristic<\/p>\n<\/td>\n<td>\n<p>B Curve, D Curve<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Mechanical features<\/p>\n<\/td>\n<td>\n<p>Electrical life<\/p>\n<\/td>\n<td>\n<p>\u22651500<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Mechanical life<\/p>\n<\/td>\n<td>\n<p>\u226520000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Contact position indicator<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Protection degree<\/p>\n<\/td>\n<td>\n<p>IP20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Reference temperature for setting of thermal element(\u2103)<\/p>\n<\/td>\n<td>\n<p>30<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Ambient temperature(with daily average\u226435\u2103)<\/p>\n<\/td>\n<td>\n<p>-5\u2026+40\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Storage temperature<\/p>\n<\/td>\n<td>\n<p>-25\u2026+70\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Installation<\/p>\n<\/td>\n<td>\n<p>Terminal connection type<\/p>\n<\/td>\n<td>\n<p>Cable\/U-type busbar\/Pin-type busbar<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Terminal size top\/bottom for cable<\/p>\n<\/td>\n<td>\n<p>25mm2 \/ 18-4 AWG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Terminal size top\/bottom for busbar<\/p>\n<\/td>\n<td>\n<p>10mm2 \/ 18-8AWG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Tightening torque<\/p>\n<\/td>\n<td>\n<p>2.5N*M \/ 22 In-lbs<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Mounting<\/p>\n<\/td>\n<td>\n<p>On DIN rail EN 60715(35mm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Combination with accessories<\/p>\n<\/td>\n<td>\n<p>Auxiliary contact<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Shunt release<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Under voltage release<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Alarm contact<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>JC3BE-DC High-Performance DC Circuit Breaker Engineered for superior protection in high-voltage DC applications up to 1000V. Breaking capacity up to 10kA Rated current up to 63ARated voltage up to 1000V DC1 Pole, 2 Pole, 3 Pole , 4 Pole are available Advanced Short-Circuit &amp; Overload Protection Clear Contact Indicator for safe status confirmation IEC 60898-1Certified The ultimate choice for efficiency and safety in your DC infrastructure.<\/p>","protected":false},"featured_media":2928,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[81],"product_tag":[],"class_list":["post-2927","product","type-product","status-publish","has-post-thumbnail","product_cat-mcb","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product\/2927","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/comments?post=2927"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/media\/2928"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/media?parent=2927"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product_brand?post=2927"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product_cat?post=2927"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product_tag?post=2927"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}