{"id":2546,"date":"2026-07-30T11:30:26","date_gmt":"2026-07-30T03:30:26","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/air-circuit-breaker-wew3-1600-acb-breaker-withdrawable-type-acb-fixed-type-type-1000vac-1500vac-2500a-3p-acb-4p-acb\/"},"modified":"2026-09-29T17:09:57","modified_gmt":"2026-09-29T09:09:57","slug":"air-circuit-breaker-wew3-1600-acb-breaker-withdrawable-type-acb-fixed-type-type-1000vac-1500vac-2500a-3p-acb-4p-acb","status":"publish","type":"product","link":"https:\/\/w9-group.com\/fa\/product\/air-circuit-breaker-wew3-1600-acb-breaker-withdrawable-type-acb-fixed-type-type-1000vac-1500vac-2500a-3p-acb-4p-acb\/","title":{"rendered":"\u0642\u0637\u0639 \u06a9\u0646\u0646\u062f\u0647 \u0645\u062f\u0627\u0631 \u0647\u0648\u0627\u06cc\u06cc WEW3-1600 \u0646\u0648\u0639 ACB\u060c \u0646\u0648\u0639 \u06a9\u0634\u0648\u06cc\u06cc\u060c \u0646\u0648\u0639 \u062b\u0627\u0628\u062a\u060c \u0648\u0644\u062a\u0627\u0698 1000VAC\/1500VAC\u060c \u062c\u0631\u06cc\u0627\u0646 2500A\u060c \u0646\u0648\u0639 3p ACB\u060c \u0646\u0648\u0639 4p ACB"},"content":{"rendered":"<h2>\nthe\u00a0function\u00a0and\u00a0advantage\u00a0of\u00a0solar\u00a0air\u00a0circuit\u00a0breaker<br \/>\n<\/h2>\n<p>800V ACB, 800-1140V ACB and solar air circuit breakers are commonly used in solar power generation systems to protect and control electrical equipment in solar power generation systems.\u00a0<br \/>\nThese air circuit breakers typically have the following features:<br \/>\nHigh voltage level: suitable for high-voltage electrical systems from 800V to 1140V to ensure safe and reliable operation of the system.<\/p>\n<h2>\nMain performance index of WEW1 series circuit breaker<br \/>\n<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"10\">\nWEW3 Air Circuit Breaker<\/td>\n<td colspan=\"4\">1600<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"1\" colspan=\"10\">Rated operating\u00a0current In (A),40\u2103<\/td>\n<td colspan=\"4\">200-400-630-800-1000-1250-1600<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">\u0648\u0644\u062a\u0627\u0698 \u0639\u0627\u06cc\u0642\u06cc \u0645\u062c\u0627\u0632 Ui (V)<\/td>\n<td colspan=\"4\">1000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">\u062a\u0648\u0644\u06cc\u062f \u0628\u0631\u0642 \u0628\u0627 \u0648\u0644\u062a\u0627\u0698 \u0627\u0646\u0642\u0628\u0627\u0636\u06cc (kV)<\/td>\n<td colspan=\"4\">12<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">\u0648\u0644\u062a\u0627\u0698 \u0639\u0645\u0644\u06cc\u0627\u062a\u06cc \u062a\u0639\u06cc\u06cc\u0646 \u0634\u062f\u0647 Ue(V)\u060c AC 50\/60Hz<\/td>\n<td colspan=\"4\">400V\/690V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Use category<\/td>\n<td colspan=\"4\">B<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">\u0648\u0644\u062a\u0627\u0698 \u0639\u0645\u0644\u06cc\u0627\u062a\u06cc \u062a\u0639\u06cc\u06cc\u0646 \u0634\u062f\u0647 Ue(V)\u060c AC 50\/60Hz<\/td>\n<td colspan=\"4\">100%In<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">\u0631\u0645\u0632 \u062a\u0648\u0627\u0646\u0627\u06cc\u06cc \u0634\u06a9\u0633\u062a<\/td>\n<td colspan=\"2\">M<\/td>\n<td colspan=\"2\">H<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">\u062a\u0639\u062f\u0627\u062f \u0633\u062a\u0648\u0646<\/td>\n<td colspan=\"5\">\u06f3P<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">4P<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">\n\u0628\u0647\u062a\u0631\u06cc\u0646 \u0631\u062a\u0628\u0647<br \/>\n\u0642\u0637\u0639 \u0645\u062f\u0627\u0631<br \/>\ncapacity Icu (kA)\n<\/td>\n<td colspan=\"5\">AC380V\/400V\/415V<\/td>\n<td colspan=\"2\">55<\/td>\n<td colspan=\"2\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC690V<\/td>\n<td colspan=\"2\">25<\/td>\n<td colspan=\"2\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC800V\/1140V<\/td>\n<td colspan=\"2\">\u2013<\/td>\n<td colspan=\"2\">\u2013<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">\n\u062e\u0631\u0627\u0628\u06cc \u062e\u062f\u0645\u0627\u062a \u0631\u062a\u0628\u0647\u0628\u0646\u062f\u06cc \u0634\u062f\u0647<br \/>\ncapacity Ics (kA)\n<\/td>\n<td colspan=\"5\">AC380V\/400V\/415V<\/td>\n<td colspan=\"2\">42<\/td>\n<td colspan=\"2\">55<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC690V<\/td>\n<td colspan=\"2\">20<\/td>\n<td colspan=\"2\">42<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC800V\/1140V<\/td>\n<td colspan=\"2\">\u2013<\/td>\n<td colspan=\"2\">\u2013<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">\nRated short-time withstand\u00a0<br \/>\ncurrent Icw (kA\/1s)\n<\/td>\n<td colspan=\"5\">AC380V\/400V\/415V<\/td>\n<td colspan=\"2\">42<\/td>\n<td colspan=\"2\">55<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC690V<\/td>\n<td colspan=\"2\">20<\/td>\n<td colspan=\"2\">42<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC800V\/1140V<\/td>\n<td colspan=\"2\">\u2013<\/td>\n<td colspan=\"2\">\u2013<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\n\u0632\u0645\u0627\u0646 \u06a9\u0627\u0631\u06a9\u0631\u062f \u0645\u06a9\u0627\u0646\u06cc\u06a9\u06cc<br \/>\n(\u0628\u0627\u0632\u06cc\u0627\u0641\u062a CO)\n<\/td>\n<td colspan=\"5\">\u062e\u062f\u0645\u0627\u062a \u0646\u06af\u0647\u062f\u0627\u0631\u06cc<\/td>\n<td colspan=\"4\">20000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">\n\u0632\u0646\u062f\u06af\u06cc \u0627\u0644\u06a9\u062a\u0631\u06cc\u06a9\u06cc<br \/>\n(\u0628\u0627\u0632\u06cc\u0627\u0641\u062a CO)\n<\/td>\n<td colspan=\"5\">AC415V,In<\/td>\n<td colspan=\"4\">2000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC690V,In<\/td>\n<td colspan=\"4\">1000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Standard configuration<\/td>\n<td colspan=\"2\">\u0631\u0641\u0639 \u0627\u0634\u06a9\u0627\u0644<\/td>\n<td colspan=\"2\">Drawetry-pe<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">The body of the circuit breaker<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Drawer base<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Intelligent controller<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Upper and lower horizontal connecting wires<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Indicating contact of opening\/closing<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Indicating contact of fault tripping<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Auxiliary contact 4NO+4NC<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Electric motor operating mechanism<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Shunt releas<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<td colspan=\"2\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"14\">Optional accessories<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Phase partition<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Instantaneous undervoltage release<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Time-delay undervoltage release<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Opening and closing button lock<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Lock for the drawer base<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Lock for the separation position of the drawer seat<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Key lock<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Door interlock<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Auxiliary contact 6NO+6NC<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Electric indications of three positions on the drawer base<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Steel cable interlock<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Locking interlock<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Dual power controller<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">External neutral line transformer<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Zero-sequence transformer<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Ground current transformer and its accessories<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<td colspan=\"2\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"14\">\u0627\u0628\u0639\u0627\u062f<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">\n\u0627\u0628\u0639\u0627\u062f (\u0645\u06cc\u0644\u06cc \u0645\u062a\u0631)<br \/>\n\u0639\u0631\u0636 \u00d7 \u0627\u0631\u062a\u0641\u0627\u0639 \u00d7 \u0639\u0645\u0642\n<\/td>\n<td colspan=\"5\">Width (3P\/4P)<\/td>\n<td colspan=\"2\">36.5\/46<\/td>\n<td colspan=\"2\">46.5\/46<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\u0627\u0631\u062a\u0641\u0627\u0639<\/td>\n<td colspan=\"2\">43\/55<\/td>\n<td colspan=\"2\">51\/55<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\u0639\u0645\u0642<\/td>\n<td colspan=\"2\">32.5\/42<\/td>\n<td colspan=\"2\">37\/42<\/td>\n<\/tr>\n<tr>\n<td colspan=\"14\">\u0648\u0632\u0646<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">\u0648\u0632\u0646 (\u06a9\u06cc\u0644\u0648\u06af\u0631\u0645)\/\u062b\u0627\u0628\u062a<\/td>\n<td colspan=\"5\">\u06f3P<\/td>\n<td colspan=\"4\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">4P<\/td>\n<td colspan=\"4\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Weight(kg)\/Drawer<\/td>\n<td colspan=\"5\">\u06f3P<\/td>\n<td colspan=\"4\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">4P<\/td>\n<td colspan=\"4\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Rated Current : 1600A Number Of Poles : 3P\/4P Rated Working Voltage : 400V\/690V<\/p>","protected":false},"featured_media":2547,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[93],"product_tag":[],"class_list":["post-2546","product","type-product","status-publish","has-post-thumbnail","product_cat-solar-800vac-acb","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product\/2546","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/comments?post=2546"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/media\/2547"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/media?parent=2546"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product_brand?post=2546"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product_cat?post=2546"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product_tag?post=2546"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}