{"id":2410,"date":"2026-07-30T11:29:17","date_gmt":"2026-07-30T03:29:17","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/wlm6ely-250a-3300-3p-wlm6e-series-electronic-circuit-breaker-lsig-circuit-breaker-mccb-250a-3-poles\/"},"modified":"2026-07-30T11:29:19","modified_gmt":"2026-07-30T03:29:19","slug":"wlm6ely-250a-3300-3p-wlm6e-series-electronic-circuit-breaker-lsig-circuit-breaker-mccb-250a-3-poles","status":"publish","type":"product","link":"https:\/\/w9-group.com\/fa\/product\/wlm6ely-250a-3300-3p-wlm6e-series-electronic-circuit-breaker-lsig-circuit-breaker-mccb-250a-3-poles\/","title":{"rendered":"MCCB circuit breaker WLM6ELY-250A-4300 3P WLM6E Series electronic lsig 250A 4 Poles"},"content":{"rendered":"<h2>\nResidual Current Circuit Breaker with Liquid Crystal Display (RCCB with LCD Type): Functions and Benefits<br \/>\n<\/h2>\n<p>Real-time Monitoring: The LCD display provides real-time monitoring of electrical parameters, including current, voltage, and residual current. This allows users to track the status of the electrical system and identify any abnormalities or faults.<br \/>\nFault Indication: The LCD display is equipped to indicate various types of faults, such as earth leakage, overcurrent, and short circuits. This feature enables prompt identification and troubleshooting of electrical faults, minimizing downtime and ensuring continuous operation.<\/p>\n<h2>\nMain performance index of WLM6LEY series circuit breaker<br \/>\n<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"10\">\nWLM6LEY Moulded Case Circuit Breaker<\/td>\n<td colspan=\"4\">250<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" colspan=\"5\">Rated current (A) of circuit breaker 40\u2103<\/td>\n<td colspan=\"5\">Fix type<\/td>\n<td colspan=\"4\">\n100-125-140-150-160<br \/>\n175-180-200-225-250\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Lcd type<\/td>\n<td colspan=\"4\">\n100-125-140-150-160<br \/>\n175-180-200-225-250\n<\/td>\n<\/tr>\n<tr><\/tr>\n<tr>\n<td colspan=\"10\">Rated insulation voltage Ui (V)<\/td>\n<td colspan=\"4\">1000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated impulse withstand voltage (kV)<\/td>\n<td colspan=\"4\">8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated operational voltage Ue(V),AC 50\/60Hz<\/td>\n<td colspan=\"4\">AC400V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Breaking capacity code<\/td>\n<td colspan=\"1\">C<\/td>\n<td colspan=\"1\">S<\/td>\n<td colspan=\"1\">M<\/td>\n<td colspan=\"1\">H<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">Number of poles<\/td>\n<td colspan=\"5\">2P<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">3P<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">4P<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">\nRated ultimate<br \/>\nshort-circuit breaking<br \/>\ncapacity Icu (kA)\n<\/td>\n<td colspan=\"5\">AC380\/400\/415V<\/td>\n<td colspan=\"1\">15<\/td>\n<td colspan=\"1\">25<\/td>\n<td colspan=\"1\">35<\/td>\n<td colspan=\"1\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC380\/400\/415V<\/td>\n<td colspan=\"1\">10<\/td>\n<td colspan=\"1\">18<\/td>\n<td colspan=\"1\">25<\/td>\n<td colspan=\"1\">35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\nRated residual making and breaking capacity<br \/>\nI\u25b3 m(kA)\n<\/td>\n<td colspan=\"5\">AC220\/230\/240V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">12.5<\/td>\n<td colspan=\"1\">12.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Limit non-actuating time \u25b3 t (ms)<\/td>\n<td colspan=\"4\">0.06s\/0.2s\/0.5s\/1s<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Leakage alarm non-tripping function<\/td>\n<td colspan=\"4\">\u25a1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">overcurrent tripping type<\/td>\n<td colspan=\"4\">Themal type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Leakage tripping type<\/td>\n<td colspan=\"4\">Electronic Type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Residual current type<\/td>\n<td colspan=\"4\">AC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Standard<\/td>\n<td colspan=\"4\">IEC\/EN 60947-2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Utilization category<\/td>\n<td colspan=\"4\">A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Ambient temperature<\/td>\n<td colspan=\"4\">-40\u2103 ~+70 \u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Safety of insulation<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Arcing distance<\/td>\n<td colspan=\"4\">0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\nMechanical life<br \/>\n(CO recycle)\n<\/td>\n<td colspan=\"5\">Maintenance<\/td>\n<td colspan=\"4\">15000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">\nElectrical life<br \/>\n(CO recycle)\n<\/td>\n<td colspan=\"5\">AC415V,In<\/td>\n<td colspan=\"4\">8000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC690V,In<\/td>\n<td colspan=\"4\">2000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"14\">Release units<\/td>\n<\/tr>\n<tr>\n<td colspan=\"14\">Mounting and connection<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Fixed<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Plug-in<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Draw-out\n<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"4\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"4\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DIN rail<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"4\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"14\">Dimension<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">\nDimension (mm)<br \/>\nW\u00d7H\u00d7D\n<\/td>\n<td colspan=\"5\">Width (2P\/3P\/4P)<\/td>\n<td colspan=\"4\">-\/105\/140<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Height<\/td>\n<td colspan=\"4\">165<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Depth<\/td>\n<td colspan=\"4\">68<\/td>\n<\/tr>\n<tr>\n<td colspan=\"14\">Weight<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">Distribution protection<\/td>\n<td colspan=\"5\">2P<\/td>\n<td colspan=\"4\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">3P<\/td>\n<td colspan=\"4\">1.532<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">4P<\/td>\n<td colspan=\"4\">2.024<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>\n<table>\n<tbody>\n<tr>\n<td>Electronic tripper<\/td>\n<td>Frame rated<br \/>\ncurrent\u00a0Inm(A<\/td>\n<td>Rated\u00a0curren<br \/>\n)\u00a0\u00a0\u00a0In(A)<\/td>\n<td>t<\/p>\n<p>Setting current of adjustable overload\u00a0release\u00a0IR(A)<\/td>\n<td>Tripping characteristic\/time<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"15\">\u00a0<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<p>Overload long-time<\/p>\n<p>delay<\/td>\n<td rowspan=\"3\">125<\/td>\n<td>32<\/td>\n<td>12.5-14-16-18-20-22-25-28-30-32<\/td>\n<td rowspan=\"15\">\u00a0<\/p>\n<p>\u00a0<\/p>\n<p>1.05In non tripping time (\u2265 2 hours, In&gt;63A;);<\/p>\n<p>1.30 In trip time (&lt;2 hours, In&gt;63A);<\/td>\n<\/tr>\n<tr>\n<td>63<\/td>\n<td>25-28-32-36-40-45-50-56-60-63<\/td>\n<\/tr>\n<tr>\n<td>125<\/td>\n<td>50-56-63-70-75-80-90-100-110-125<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">160<\/td>\n<td>63<\/td>\n<td>25-28-32-36-40-45-50-56-60-63<\/td>\n<\/tr>\n<tr>\n<td>125<\/td>\n<td>50-56-63-70-75-80-90-100-110-125<\/td>\n<\/tr>\n<tr>\n<td>160<\/td>\n<td>63-70-80-90-100-110-125-140-150-160<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>250<\/td>\n<td>100-110-125-140-150-160-180-200-225-250<\/td>\n<\/tr>\n<tr>\n<td>320<\/td>\n<td>320<\/td>\n<td>125-140-160-180-200-225-250-280-300-320<\/td>\n<\/tr>\n<tr>\n<td>400<\/td>\n<td>400<\/td>\n<td>160-180-200-225-250-280-315-350-375-400<\/td>\n<\/tr>\n<tr>\n<td>630<\/td>\n<td>630<\/td>\n<td>250-280-315-350-375-400-450-500-560-630<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">800<\/td>\n<td>630<\/td>\n<td>250-280-315-350-375-400-450-500-560-630<\/td>\n<\/tr>\n<tr>\n<td>800<\/td>\n<td>315-350-400-450-500-560-630-700-760-800<\/td>\n<\/tr>\n<tr>\n<td>1250<\/td>\n<td>1250<\/td>\n<td>500-630-700-800-850-900-950-1050-1150-1250<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">1250<\/p>\n<p>Custom-<\/p>\n<p>made<\/td>\n<td>1000<\/td>\n<td>630-680-700-750-800-850-900-950-1000<\/td>\n<\/tr>\n<tr>\n<td>1250<\/td>\n<td>850-900-950-1000-1050-1100-1150-1200-1250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Action tolerance<\/td>\n<td>\u00b120%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Rated Current : 250A Number Of Poles : 4P Rated Working Voltage : 400V\/690V<\/p>","protected":false},"featured_media":2411,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[82,180],"product_tag":[],"class_list":["post-2410","product","type-product","status-publish","has-post-thumbnail","product_cat-lcd-with-modbus-mccb","product_cat-wlm6ely","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product\/2410","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/comments?post=2410"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/media\/2411"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/media?parent=2410"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product_brand?post=2410"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product_cat?post=2410"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/product_tag?post=2410"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}