{"id":3409,"date":"2026-03-24T09:00:00","date_gmt":"2026-03-24T01:00:00","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/blog\/advanced-protection-of-800v-mccb-electronic-jcr3hm-rcd-with-built-in-lsig-trip-unit\/"},"modified":"2026-10-20T10:37:31","modified_gmt":"2026-10-20T02:37:31","slug":"%d9%85%d8%ad%d8%a7%d9%81%d8%b8%d8%aa-%d9%be%db%8c%d8%b4%d8%b1%d9%81%d8%aa%d9%87-%d8%a7%d8%b2-mcb-%d8%a7%d9%84%da%a9%d8%aa%d8%b1%d9%88%d9%86%db%8c%da%a9%db%8c-800-%d9%88%d9%84%d8%aa-%d8%a8%d8%a7-%d9%82","status":"publish","type":"post","link":"https:\/\/w9-group.com\/fa\/blog\/advanced-protection-of-800v-mccb-electronic-jcr3hm-rcd-with-built-in-lsig-trip-unit\/","title":{"rendered":"JCR3HM RCCB \u0648 LSIG MCCB: \u0639\u0645\u0644\u06a9\u0631\u062f\u200c\u0647\u0627\u06cc \u062d\u0641\u0627\u0638\u062a\u06cc \u0648 \u0645\u062d\u062f\u0648\u062f\u06cc\u062a\u0647\u0627\u06cc \u0631\u062a\u0628\u0647\u0628\u0646\u062f\u06cc"},"content":{"rendered":"<p>The older title combines two different device descriptions: an 800 V electronic MCCB with LSIG and the JCR3HM RCD. They must not be treated as one product. The current JCR3HM listing identifies an <a href=\"https:\/\/w9-group.com\/fa\/%d9%85%d8%ad%d8%b5%d9%88%d9%84%d8%a7%d8%aa-%d8%ad%d9%81%d8%a7%d8%b8%d8%aa-%d9%85%d8%af%d8%a7%d8%b1\/rccb-circuit-protection-products\/\">RCCB<\/a> for residual-current protection, with separate coordinated overcurrent protection required.<\/p>\n<p>\u0627\u06cc\u0646 <strong>JCR3HM RCCB<\/strong> table lists 2P\/4P, Type A or AC, 30\/100\/300 mA options and current choices from 25 to 100 A. It lists 230\/240 V for 2P and 400\/415 V for 4P. It does not establish an 800 V LSIG MCCB rating.<\/p>\n<h2>What JCR3HM does<\/h2>\n<p>It detects residual current within the selected waveform and sensitivity scope. An RCCB under IEC 61008-1 has no <strong>integral overcurrent protection<\/strong>. Its current-carrying rating must therefore be coordinated with the circuit&#8217;s MCB or fuse and the manufacturer&#8217;s fault-protection arrangement.<\/p>\n<p>Choose waveform type from the connected load and sensitivity from the protection objective and installation rules. A 300 mA setting cannot simply replace required 30 mA additional protection to avoid trips.<\/p>\n<p>Review the difference between <a href=\"https:\/\/w9-group.com\/fa\/blog\/%d8%aa%d9%81%d8%a7%d9%88%d8%aa-%d8%a8%db%8c%d9%86-rcbo-%d9%88-rccb-2-%da%86%db%8c%d8%b3%d8%aa%d8%9f\/\">RCBO and RCCB protection<\/a> before allocating overload and residual-current functions.<\/p>\n<h2>What an LSIG MCCB does<\/h2>\n<p>\u06cc\u06a9 <strong>LSIG MCCB<\/strong> provides declared long-time, short-time, instantaneous and ground-fault functions. Its ground-fault function is not automatically equivalent to the high-sensitivity residual-current function required on a final circuit. Voltage, fault duty and sensing arrangements must come from its own exact model table.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u0632\u0645\u06cc\u0646<\/th>\n<th>JCR3HM listing<\/th>\n<th>Electronic LSIG MCCB<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0631\u0634\u062a\u0647 \u0645\u062d\u0635\u0648\u0644\u0627\u062a<\/td>\n<td>RCCB<\/td>\n<td>MCCB with specified electronic release<\/td>\n<\/tr>\n<tr>\n<td>\u062d\u0641\u0627\u0638\u062a \u062f\u0631 \u0628\u0631\u0627\u0628\u0631 \u062c\u0631\u06cc\u0627\u0646 \u0628\u06cc\u0634 \u0627\u0632 \u062d\u062f<\/td>\n<td>Separate coordinated device required<\/td>\n<td>Declared L\/S\/I functions<\/td>\n<\/tr>\n<tr>\n<td>Leakage or earth-fault function<\/td>\n<td>Selected residual-current type and sensitivity<\/td>\n<td>Ground-fault function within release scope<\/td>\n<\/tr>\n<tr>\n<td>\u0648\u0644\u062a\u0627\u0698<\/td>\n<td>Listed 2P and 4P values<\/td>\n<td>Exact MCCB rating table required<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u0631\u0627\u0647\u0646\u0645\u0627\u06cc <a href=\"https:\/\/w9-group.com\/fa\/blog\/%d8%a7%d9%87%d9%85%db%8c%d8%aa-rccb-%d8%af%d8%b1-%d8%a7%db%8c%d9%85%d9%86%db%8c-%d8%a7%d9%84%da%a9%d8%aa%d8%b1%db%8c%da%a9%db%8c-%d9%88-%d8%ad%d9%81%d8%a7%d8%b8%d8%aa-%d8%a7%d8%b2-%d8%ac%d8%a7%d9%86\/\">\u062d\u0641\u0627\u0638\u062a \u0627\u0632 \u062c\u0631\u06cc\u0627\u0646 \u0628\u0627\u0642\u06cc \u0645\u0627\u0646\u062f\u0647<\/a> describes the installation conditions that a device label alone cannot establish.<\/p>\n<p><img decoding=\"async\" alt=\"800 \u0648\u0644\u062a\u06cc \u0645\u06a9\u062a\u0648\u0628 \u0627\u0644\u06a9\u062a\u0631\u0648\u0646\u06cc\u06a9\u06cc \u0628\u0627 \u0642\u0627\u0628\u0644\u06cc\u062a \u0646\u0635\u0628 \u0648\u0627\u062d\u062f \u0627\u0639\u0644\u0627\u0645 \u062e\u0637\u0627\u06cc Lsig Trip Unit.jpg\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/upload\/p\/1205\/image_product\/2024-09\/3-pole-acb-drawer-type-fixed-type.jpg\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\" width=\"300\"\/><\/p>\n<h2>Keep the two specifications separate<\/h2>\n<p>For JCR3HM, request poles, current, Type A or AC, <strong>\u062d\u0633\u0627\u0633\u06cc\u062a \u0628\u0647 \u062c\u0631\u06cc\u0627\u0646 \u0628\u0627\u0642\u06cc \u0645\u0627\u0646\u062f\u0647<\/strong> and coordination evidence. For an 800 V MCCB requirement, request a different exact product code with explicit AC or DC operating voltage and fault ratings. Neither product&#8217;s name supplies the other&#8217;s functions.<\/p>\n<table>\n<thead>\n<tr>\n<th>Order<\/th>\n<th>Essential evidence<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>JCR3HM RCCB<\/td>\n<td>RCCB datasheet, wiring and overcurrent coordination<\/td>\n<\/tr>\n<tr>\n<td>800 V MCCB<\/td>\n<td>Exact voltage and fault-duty table, trip curves and connections<\/td>\n<\/tr>\n<tr>\n<td>Complete panel<\/td>\n<td>Assembly verification and installation design<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Installation and procurement checks<\/h2>\n<p>Neutral routing, earthing and test procedures remain important for the RCCB. Use the declared test method and a suitable residual-current tester. IEC 61008-1 and IEC 60947-2 have different product scopes; listing both does not combine two device categories.<\/p>\n<p>Ask W9 Group to confirm the exact required product before quotation. Keep the RCCB and MCCB schedules separate so a misleading legacy title cannot become a purchasing instruction.<\/p>\n<section id=\"faq\">\n<h2>\u0633\u0648\u0627\u0644\u0627\u062a \u0645\u062a\u062f\u0627\u0648\u0644<\/h2>\n<h3>Is JCR3HM an 800 V LSIG MCCB?<\/h3>\n<p>No. The reviewed current listing identifies an RCCB with separate overcurrent protection required. It does not establish that combined description.<\/p>\n<h3>Does JCR3HM provide overload protection by itself?<\/h3>\n<p>No. Its RCCB function requires a coordinated MCB or fuse for overload and short-circuit protection.<\/p>\n<h3>Is an MCCB ground-fault function the same as a 30 mA RCD?<\/h3>\n<p>Not automatically. Sensitivity, waveform response, sensing and intended protection differ. Verify the exact functions required by the installation.<\/p>\n<h3>How should an 800 V requirement be quoted?<\/h3>\n<p>Specify a separate exact MCCB with the required AC or DC voltage, fault duty, poles and trip functions. Do not infer it from the JCR3HM name.<\/p>\n<\/section>\n<h2>\u0645\u0646\u0627\u0628\u0639<\/h2>\n<ul>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/67980\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61008-1:2024 \u2014 RCCBs \u0628\u062f\u0648\u0646 \u062d\u0641\u0627\u0638\u062a \u0627\u0632 \u062c\u0631\u06cc\u0627\u0646 \u0628\u06cc\u0634 \u0627\u0632 \u062d\u062f<\/a>.<\/li>\n<li><a href=\"https:\/\/electrical.theiet.org\/wiring-matters\/years\/2019\/77-september-2019\/which-rcd-type\/\" rel=\"nofollow noopener\" target=\"_blank\">IET \u2014 \u0686\u0647 \u0646\u0648\u0639 \u0631\u0627\u062f\u06cc\u0627\u062a\u0648\u0631 \u0631\u0627 \u0627\u0646\u062a\u062e\u0627\u0628 \u06a9\u0646\u0645\u061f<\/a>.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/24656\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60364-6:2016 \u2013 \u062a\u0623\u06cc\u06cc\u062f \u0646\u0635\u0628<\/a>.<\/li>\n<\/ul>\n<p>\u0628\u0631\u0627\u06cc \u0627\u0646\u062a\u062e\u0627\u0628 \u0634\u06a9\u0644 \u0645\u0648\u062c \u0648 \u0642\u0637\u0628\u060c, <a href=\"https:\/\/w9-group.com\/fa\/%d8%a8%d8%a7-%d9%85%d8%a7-%d8%aa%d9%85%d8%a7%d8%b3-%d8%a8%da%af%db%8c%d8%b1%db%8c%d8%af\/\">\u062a\u0645\u0627\u0633 \u0628\u0627 \u06af\u0631\u0648\u0647 W9<\/a> \u0628\u0627 \u062a\u0648\u067e\u0648\u0644\u0648\u0698\u06cc \u0645\u062f\u0627\u0631\u060c \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0628\u0627\u0631\u06af\u0630\u0627\u0631\u06cc \u0648 \u0642\u0648\u0627\u0646\u06cc\u0646 \u0628\u0627\u0632\u0627\u0631 \u0645\u0642\u0635\u062f.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0628\u0627 \u0631\u06a9\u0648\u0631\u062f\u0627\u0631 \u062c\u0631\u06cc\u0627\u0646 800 \u0648\u0644\u062a JCR3HM RCD MCCB \u0627\u0632 \u062d\u0641\u0627\u0638\u062a \u067e\u06cc\u0634\u0631\u0641\u062a\u0647 \u0628\u0647\u0631\u0647 \u0628\u0628\u0631\u06cc\u062f. \u0648\u0627\u062d\u062f \u0642\u0637\u0639 \u062c\u0631\u06cc\u0627\u0646 LSIG \u062f\u0627\u062e\u0644\u06cc \u0628\u0631\u0627\u06cc \u062d\u062f\u0627\u06a9\u062b\u0631 \u0627\u0645\u0646\u06cc\u062a. \u0628\u0647\u062a\u0631\u06cc\u0646 \u067e\u06cc\u0634\u0646\u0647\u0627\u062f\u0627\u062a \u0631\u0627 \u0628\u0631\u0627\u06cc \u0646\u06cc\u0627\u0632\u0647\u0627\u06cc \u0628\u0631\u0642\u06cc\u062a\u0627\u0646 \u067e\u06cc\u062f\u0627 \u06a9\u0646\u06cc\u062f.<\/p>","protected":false},"author":1,"featured_media":3801,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3409","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/posts\/3409","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/comments?post=3409"}],"version-history":[{"count":4,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/posts\/3409\/revisions"}],"predecessor-version":[{"id":4675,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/posts\/3409\/revisions\/4675"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/media\/3801"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/media?parent=3409"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/categories?post=3409"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/tags?post=3409"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}