{"id":3398,"date":"2026-03-02T09:00:00","date_gmt":"2026-03-02T01:00:00","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/blog\/jcb3-63dc-polarity-dc-miniature-circuit-breaker-mcb-ultimate-guide\/"},"modified":"2026-10-20T10:56:37","modified_gmt":"2026-10-20T02:56:37","slug":"jcb3-63dc-polarity-dc-miniature-circuit-breaker-mcb-ultimate-guide","status":"publish","type":"post","link":"https:\/\/w9-group.com\/fa\/blog\/jcb3-63dc-polarity-dc-miniature-circuit-breaker-mcb-ultimate-guide\/","title":{"rendered":"JCB3-63DC DC MCB: \u0628\u0631\u0631\u0633\u06cc\u200c\u0647\u0627\u06cc \u0631\u062a\u0628\u0647\u0628\u0646\u062f\u06cc\u060c \u0642\u0637\u0628\u06cc\u062a \u0648 \u0633\u06cc\u0645 \u06a9\u0634\u06cc"},"content":{"rendered":"<p>\u0628\u0631\u0631\u0633\u06cc \u06a9\u0646\u06cc\u062f <a href=\"https:\/\/w9-group.com\/fa\/%d9%81%d9%88%d8%aa%d9%88%d9%86%db%8c%da%a9\/\">photovoltaic protection range<\/a> against the maximum DC voltage and permitted pole connection.<\/p>\n<p>\u0627\u06cc\u0646 <a href=\"https:\/\/w9-group.com\/fa\/blog\/%d8%b1%d8%a7%d9%87%d9%86%d9%85%d8%a7%db%8c-%d8%a7%d8%b3%d8%a7%d8%b3%db%8c-%d9%82%d8%b7%d8%b9%da%a9%d9%86%d9%86%d8%af%d9%87-%d9%85%d8%af%d8%a7%d8%b1-%d8%ac%d8%b9%d8%a8%d9%87%d8%b4\/\">DC MCCB guide<\/a> explains why an AC rating cannot establish DC interruption capability.<\/p>\n<h2>JCB3-63DC rating and documentation matrix<\/h2>\n<div class=\"scroll\">\n<table>\n<thead>\n<tr>\n<th>\u0632\u0645\u06cc\u0646<\/th>\n<th>Reviewed table<\/th>\n<th>\u062a\u0648\u0636\u06cc\u062d\u0627\u062a \u0644\u0627\u0632\u0645<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0645\u0648\u062c\u0648\u062f\u0647<\/td>\n<td>6\u201363 A options<\/td>\n<td>Exact current and B\/C curve<\/td>\n<\/tr>\n<tr>\n<td>Pole count<\/td>\n<td>1P through 4P<\/td>\n<td>Approved wiring arrangement<\/td>\n<\/tr>\n<tr>\n<td>\u0648\u0644\u062a\u0627\u0698<\/td>\n<td>Pole-dependent values<\/td>\n<td>Actual version and connection<\/td>\n<\/tr>\n<tr>\n<td>Fault rating<\/td>\n<td>6 kA entry<\/td>\n<td>Applicable voltage and test conditions<\/td>\n<\/tr>\n<tr>\n<td>Polarity<\/td>\n<td>Conflicting public wording<\/td>\n<td>Delivered marking and written instructions<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"scroll\">\n<table>\n<thead>\n<tr>\n<th>Project state<\/th>\n<th>Review<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Normal operation<\/td>\n<td>Current direction and conductor protection<\/td>\n<\/tr>\n<tr>\n<td>Fault<\/td>\n<td>All possible source contributions<\/td>\n<\/tr>\n<tr>\n<td>\u062e\u062f\u0645\u0627\u062a \u0646\u06af\u0647\u062f\u0627\u0631\u06cc<\/td>\n<td>Isolation of every source<\/td>\n<\/tr>\n<tr>\n<td>Replacement<\/td>\n<td>Matching code, markings and diagram<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>\u0627\u06cc\u0646 <a href=\"https:\/\/w9-group.com\/fa\/blog\/%d8%af%d8%b1%da%a9-%d9%86%d9%82%d8%b4-mccb-%d8%af%d8%b1-%d8%ae%d8%b7%d9%88%d8%b7-%d8%aa%d9%88%d8%b2%db%8c%d8%b9-%d9%81%d8%aa%d9%88%d9%88%d9%84%d8%aa%d8%a7%d8%a6%db%8c%da%a9\/\">photovoltaic distribution guide<\/a> distinguishes PV-string assumptions from battery fault-current duties.<\/p>\n<p><img decoding=\"async\" alt=\"Reference illustration: JCB3-63DC rating and documentation matrix\" itemprop=\"image\" src=\"https:\/\/ecdn6.globalso.com\/upload\/p\/1205\/image_product\/2024-08\/6-13.jpg\" style=\"display:block;width:50%;max-width:50%;height:auto;margin:0 auto\"\/><\/p>\n<h2>Resolve polarity before wiring<\/h2>\n<p>The current table lists 6\u201363 A, B\/C curves, 1P through 4P and <strong>pole-dependent DC voltages<\/strong> up to the stated four-pole configuration. It also lists 6 kA, whose applicable voltage and connection conditions must be confirmed. These entries do not settle the inconsistency between polarity descriptions in the surrounding prose.<\/p>\n<p>Request the delivered unit&#8217;s terminal markings, exact order code and approved diagram. Assess normal and possible fault-current directions for the actual source arrangement. Do not use this article to infer a battery or PV wiring recipe, or assume a generic label permits bidirectional interruption.<\/p>\n<p>JCB3-63DC procurement requires a confirmed <strong>polarity diagram<\/strong>. The current public listing contains inconsistent polarity wording, so its title alone cannot determine the permitted current direction of the delivered version.<\/p>\n<p> The JCB3-63DC MCB&#8217;s compact and durable design makes it easy to install and ensures long-term reliability. Its polarized DC configuration further enhances its versatility, making it suitable for a variety of DC circuit protection applications.<\/p>\n<section id=\"faq\">\n<h2>\u0633\u0648\u0627\u0644\u0627\u062a \u0645\u062a\u062f\u0627\u0648\u0644<\/h2>\n<h3>Is JCB3-63DC polarity-sensitive?<\/h3>\n<p>The reviewed public wording is inconsistent. Obtain the exact supplied version&#8217;s markings and wiring instructions before installation.<\/p>\n<h3>Is 1000 V available from a single pole?<\/h3>\n<p>The table assigns different voltage ratings to different pole configurations. Do not apply the four-pole value to one pole or improvise series connections.<\/p>\n<h3>Does its DC label establish any battery application?<\/h3>\n<p>No. Confirm voltage, <strong>\u0636\u0631\u06cc\u0628 \u062e\u0637\u0627<\/strong>, permitted direction and source conditions for the actual battery circuit.<\/p>\n<h3>What needs to accompany a JCB3-63DC order?<\/h3>\n<p>Request the full code, current and curve, pole arrangement, <strong>voltage-specific fault-duty information<\/strong> and approved polarity diagram. Resolve discrepancies before release.<\/p>\n<\/section>\n<h2>\u0645\u0646\u0627\u0628\u0639<\/h2>\n<ul>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/66277\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60947-2:2024 \u2014 \u0645\u062d\u062f\u0648\u062f\u0647 \u0645\u062d\u0635\u0648\u0644\u0627\u062a \u0642\u0637\u0639 \u06a9\u0646\u0646\u062f\u0647 \u0645\u062f\u0627\u0631<\/a>.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/65748\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60364-7-712:2025 \u2014 \u062a\u0627\u0633\u06cc\u0633\u0627\u062a \u0628\u0631\u0642 \u0641\u062a\u0648\u0648\u0644\u062a\u0627\u0626\u06cc\u06a9<\/a>.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/107159\" rel=\"nofollow noopener\" target=\"_blank\">\u0646\u0633\u062e\u0647\u0654 \u062a\u0627\u0644\u06cc\u0641 \u0634\u062f\u0647\u0654 IEC 60947-3 \u2014 \u0633\u0648\u0626\u06cc\u0686\u200c\u0647\u0627\u060c \u0642\u0637\u0639\u200c\u06a9\u0646\u200c\u0647\u0627 \u0648 \u0642\u0637\u0639\u200c\u06a9\u0646\u200c\u0647\u0627\u06cc \u0642\u0637\u0639\u200c\u06a9\u0646<\/a>.<\/li>\n<\/ul>\n<p>\u0628\u0631\u0627\u06cc \u0627\u0646\u062a\u062e\u0627\u0628 PV \u06cc\u0627 DC\u060c, <a href=\"https:\/\/w9-group.com\/fa\/%d8%a8%d8%a7-%d9%85%d8%a7-%d8%aa%d9%85%d8%a7%d8%b3-%d8%a8%da%af%db%8c%d8%b1%db%8c%d8%af\/\">\u062a\u0645\u0627\u0633 \u0628\u0627 \u06af\u0631\u0648\u0647 W9<\/a> \u0628\u0627 \u062d\u062f\u0627\u06a9\u062b\u0631 \u0648\u0644\u062a\u0627\u0698\u060c \u062c\u0631\u06cc\u0627\u0646 \u06a9\u0627\u0631\u06cc \u0648 \u062e\u0631\u0627\u0628\u06cc\u060c \u0627\u062a\u0635\u0627\u0644 \u0628\u0647 \u0632\u0645\u06cc\u0646 \u0648 \u0627\u062a\u0635\u0627\u0644 \u0628\u0647 \u0642\u0637\u0628 \u0645\u0648\u0631\u062f \u0646\u0638\u0631.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0622\u06cc\u0627 \u0628\u0647 \u062f\u0646\u0628\u0627\u0644 \u06cc\u06a9 \u067e\u0631\u06cc\u0632 \u06a9\u0648\u0686\u06a9 \u0648 \u0642\u0627\u0628\u0644 \u0627\u0637\u0645\u06cc\u0646\u0627\u0646\u06cc \u0647\u0633\u062a\u06cc\u062f\u061f \u062f\u0631 \u0631\u0627\u0647\u0646\u0645\u0627\u06cc \u06a9\u0627\u0645\u0644 \u0645\u0627\u060c \u062f\u0631\u0628\u0627\u0631\u0647 JCB3-63DC MCB \u0628\u06cc\u0634\u062a\u0631 \u0628\u062f\u0627\u0646\u06cc\u062f. \u0628\u0647\u062a\u0631\u06cc\u0646 \u067e\u0631\u06cc\u0632 DC \u0628\u0627 \u0642\u0637\u0628\u06cc\u062a \u0645\u062a\u0646\u0627\u0642\u0636 \u0631\u0627 \u0628\u0631\u0627\u06cc \u0646\u06cc\u0627\u0632\u0647\u0627\u06cc \u062e\u0648\u062f \u067e\u06cc\u062f\u0627 \u06a9\u0646\u06cc\u062f.<\/p>","protected":false},"author":1,"featured_media":3812,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3398","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/posts\/3398","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/comments?post=3398"}],"version-history":[{"count":3,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/posts\/3398\/revisions"}],"predecessor-version":[{"id":4787,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/posts\/3398\/revisions\/4787"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/media\/3812"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/media?parent=3398"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/categories?post=3398"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/w9-group.com\/fa\/wp-json\/wp\/v2\/tags?post=3398"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}