محصولات صنعتی

  • قطع‌کن مدار‌محور MCCB WLM6LY-800A-4300 نوع 4P WLM6L حفاظت از نشت زمین RCCB 400 ولت 800 آمپر 3 پین 4 پین
  • MCCB circuit breaker WLM6LY-800A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 800A 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-800A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 800A 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-800A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 800A 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-800A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 800A 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-800A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 800A 3 poles 4 Poles Gallery image 6
  • قطع‌کن مدار‌محور MCCB WLM6LY-800A-4300 نوع 4P WLM6L حفاظت از نشت زمین RCCB 400 ولت 800 آمپر 3 پین 4 پین
  • MCCB circuit breaker WLM6LY-800A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 800A 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-800A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 800A 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-800A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 800A 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-800A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 800A 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-800A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 800A 3 poles 4 Poles Gallery image 6

MCCB زمین‌گیر WLM6LY-800

MCCB زمین‌گیر WLM6LY-800 با رتبه بندی 800 آمپر و گزینه‌های 3P/4P توسط گروه W9 فهرست شده است. جدول آن یک رهاسازی حرارتی بیش از جریان و یک رهاسازی الکترونیکی از نشت را مشخص می‌کند. برای نسخه دقیق عرضه شده، پاسخ جریان باقی مانده، ترتیب قطب‌ها و وضعیت خطای را مشخص کنید.

اطلاعات فنی

WLM6LY-800 Earth Leakage MCCB Specifications

MCCB زمین‌گیر WLM6LY-800 با رتبه بندی 800 آمپر و گزینه‌های 3P/4P توسط گروه W9 فهرست شده است. جدول آن یک رهاسازی حرارتی بیش از جریان و یک رهاسازی الکترونیکی از نشت را مشخص می‌کند. برای نسخه دقیق عرضه شده، پاسخ جریان باقی مانده، ترتیب قطب‌ها و وضعیت خطای را مشخص کنید.

WLM6LY  Moulded Case Circuit Breaker 800
Rated current (A) of circuit breaker 40℃ Fix type 500-630-700-800
Lcd type 500-630-700-800
ولتاژ عایقی مجاز Ui (V) 1000
تولید برق با ولتاژ انقباضی (kV) 8
ولتاژ عملیاتی تعیین شده Ue(V)، AC 50/60Hz AC400(3P, 3P+N, 4P)
رمز توانایی شکست C S M H
تعداد ستون 2P – – – –
۳P – – ■ ■
۴P – – ■ ■
بهترین رتبه
قطع مدار
ظرفیت آیکی (kA)
AC380/400/415V – – 50 65
AC380/400/415V – – 35 50
Rated residual making and breaking capacity
I△ m(kA)
AC220/230/240V – – 16.25 16.25
Limit non-actuating time △ t (ms) 0.06s/0.2s/0.5s/1s
Leakage alarm non-tripping function □
overcurrent tripping type Themal type
Leakage tripping type Electronic Type
Residual current type AC
استاندارد IEC/EN 60947-2
رشتهٔ بهره‌وری A
دمای محیطی -40℃ ~+70 ℃
امنیت عایق ■
فاصله قوس 0
زمان کارکرد مکانیکی
(بازیافت CO)
خدمات نگهداری 15000
زندگی الکتریکی
(بازیافت CO)
AC415V، در 8000
AC690V، در 2000
واحد‌های آزاد‌سازی
تشخیص و اتصال
رفع اشکال اتصال جلو ■
اتصال عقب ■
پلاگین اتصال جلو ■
اتصال عقب ■
توسعه اتصال جلو –
اتصال عقب –
ریل دیین اتصال جلو ■
ابعاد
ابعاد (میلی متر)
عرض × ارتفاع × عمق
Width (2P/3P/4P) 210/280
ارتفاع 275.5
عمق 103
وزن
حفاظت توزیع 2P –
۳P 8.473
۴P 11.245

راهنمای انتخاب

Selecting an 800A Earth Leakage MCCB by Sensitivity and Poles

Specify the selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode when requesting a WLM6LY-800 quotation from W9 Group.

01

Choose the ordered current

The 800 A page lists 500, 630, 700, 800 A. Confirm the selected current and full model suffix, including the pole arrangement.

02

Specify leakage protection

Provide the required sensitivity, waveform response and delay. Confirm the actual available settings; residual-current making capacity is not the sensitivity setting.

03

Check voltage and fault duty

Use the selected configuration’s operational-voltage and breaking-capacity data. Confirm the capacity code and do not substitute insulation voltage for operating voltage.

04

Define alarm, mounting and wiring

Confirm tripping versus alarm-only behavior, mounting form, neutral routing and the connection drawing. Request the required test and commissioning instructions.

Before specifying WLM6LY-800: Confirm current, poles, residual-current sensitivity and delay, alarm / trip mode, operating voltage and voltage-specific fault ratings. The source mixes generic RCCB prose and configuration data; do not treat the prose as a complete order specification.

درباره W9 Group

W9 Group 800A Earth Leakage MCCB Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WLM6LY-800 enquiry, contact W9 Group about configuration and matching product documents.

دامنه محصولات حفاظتی مدار W9 Group برای OEM و ODM
رنج حفاظت مدار W9 — تصویر کلیه دسته‌ها.

منابع مرتبط

WLM6LY-800 Residual-Current MCCB Datasheet and Wiring Requests

Use technical support and related products to specify WLM6LY-800. Request a datasheet and wiring diagram matching the selected WLM6LY-800 configuration.

سوالات متداول خریداران

WLM6LY-800 Earth Leakage MCCB FAQs: Sensitivity, Alarm and Fault Duty

Find answers about WLM6LY-800 selection, configuration and ordering.

Which current choices are listed for WLM6LY-800?

The summary identifies 800 A. The frame schedule lists 500, 630, 700, 800 A. Confirm the selected current and complete order code; the schedule is not a guaranteed adjustment range.

Is this an RCCB without overcurrent protection?

The target table describes a molded-case device with overcurrent and leakage releases. Confirm the complete protection functions in the matching datasheet; generic RCCB text is insufficient to classify the ordered unit.

What leakage sensitivity can I order?

A definitive sensitivity schedule is not established by the available page. State your required residual-current pickup and delay, then confirm the available combination with W9 Group.

Does the listed residual-current type cover every waveform?

The table lists AC residual-current response. Confirm the expected leakage waveform and required device type; do not assume support for other waveforms from the electronic release description.

Can the breaker signal leakage without tripping?

A leakage-alarm non-tripping function is marked as an option. Confirm whether it is available, which mode is supplied and how the alarm is wired for the exact order code.

How should I select voltage and breaking capacity?

Request the operational-voltage and Icu / Ics data for the pole arrangement and capacity code. Confirm discrepancies between the summary and table before installation; no universal fault rating is assigned here.

What is needed for a WLM6LY-800 quotation?

اطلاعات مورد نیاز را، تعداد، بازار مقصد و الزامات اسناد را ارسال کنید. از W9 Group درخواست کنید تا قیمت، حداقل مقدار سفارش، نمونه‌ها و زمان تحویل برای پیکربندی انتخاب شده را تأیید کند.

سؤال و جواب درباره محصول

Request a WLM6LY-800 Earth Leakage MCCB Quotation

Tell W9 Group your selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode, quantity and destination market so the selected configuration can be identified.

تماس با گروه W9