{"id":2714,"date":"2026-07-30T11:43:40","date_gmt":"2026-07-30T03:43:40","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/jc3rh-s-residual-current-device\/"},"modified":"2026-09-29T17:09:36","modified_gmt":"2026-09-29T09:09:36","slug":"jc3rh-s-residual-current-device","status":"publish","type":"product","link":"https:\/\/w9-group.com\/es\/product\/jc3rh-s-residual-current-device\/","title":{"rendered":"Residual Current Device JC3RH-S"},"content":{"rendered":"<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jc3rh-s-residual-current-device-detail-01.webp\" alt=\"Residual Current Device JC3RH-S detail image 1\" loading=\"lazy\"><\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<p>\u25cf\u00a0Electromagnetic Type<\/p>\n<p>\u25cf\u00a0Earth leakage protection<\/p>\n<p>\u25cf\u00a0Breaking capacity 6kA, or 10kA<\/p>\n<p>\u25cf\u00a0Rated current up to 100A<\/p>\n<p>\u25cf\u00a0Available in Type A or Type AC<\/p>\n<p>\u25cf\u00a0Tripping sensitivity: 30mA,100mA,300mA<\/p>\n<p>\u25cf\u00a0Connection from top or bottom<\/p>\n<p>\u25cf\u00a0Complies with IEC 61008-1, EN61008-1<\/p>\n<h2>Solicitud<\/h2>\n<p>The JC3RH-S RCD (residual current circuit breaker with overload protection) are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.<br \/><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jc3rh-s-residual-current-device-detail-02.webp\" alt=\"Residual Current Device JC3RH-S detail image 2\" loading=\"lazy\"><\/p>\n<p> Overall, the JCSD1-125 is a must-have accessory for anyone looking to increase the safety and efficiency of their electrical installations. Its intuitive design, rugged construction and compliance with industry standards make it an excellent solution for MCB and RCBO monitoring. With the JCSD1-125, users can control their circuits with confidence knowing they have a reliable and effective tool.<\/p>\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\n                                        Est\u00e1ndar\n<\/td>\n<td>\n                                        IEC61008-1 , EN61008-1\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"13\">\n                                        Caracter\u00edsticas el\u00e9ctricas\n<\/td>\n<td>\n                                        Corriente nominal en A (A)\n<\/td>\n<td>\n                                        25, 40, 50, 63, 80, 100\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Tipo\n<\/td>\n<td>\n                                        Electromagnetic\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Type (wave form of the earth leakage sensed)\n<\/td>\n<td>\n                                        AC, A, AC-G, A-G, AC-S and A-S are available\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Polacos\n<\/td>\n<td>\n                                        2 Pole, 4 Pole\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Rated voltage Ue(V)\n<\/td>\n<td>\n                                        230\/240 (2P), 400\/415(4P)\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Rated sensitivity I\u2206n\n<\/td>\n<td>\n                                        30mA,100mA,300mA are available\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Tensi\u00f3n de aislamiento Ui (V)\n<\/td>\n<td>\n                                        500\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Rated residual making and breaking capacity I\u2206m (A)\n<\/td>\n<td>\n                                        500 (In=25A\/40A), 630 (In=63A),<br \/>\n                                        1000(In=80A\/100A)\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Frecuencia nominal\n<\/td>\n<td>\n                                        50\/60Hz\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Capacidad de ruptura nominal\n<\/td>\n<td>\n                                        6kA, 10kA\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Rated impulse withstand voltage(1.2\/50) Uimp (V)\n<\/td>\n<td>\n                                        6000\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Dielectric test voltage at ind. Freq. for 1 min\n<\/td>\n<td>\n                                        2.5kV\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Nivel de contaminaci\u00f3n\n<\/td>\n<td>\n                                        2\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\">\n                                        Caracter\u00edsticas mec\u00e1nicas\n<\/td>\n<td>\n                                        Vida el\u00e9ctrica\n<\/td>\n<td>\n                                        2, 000\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Vida mec\u00e1nica\n<\/td>\n<td>\n                                        2, 000\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Indicador de posici\u00f3n de contacto\n<\/td>\n<td>\n                                        S\u00ed\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Nivel de protecci\u00f3n\n<\/td>\n<td>\n                                        IP20\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Reference temperature for setting of thermal<br \/>\n                                        element(\u00b0C)\n<\/td>\n<td>\n                                        30\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Ambient temperature (with daily average \u226435\u00b0C)\n<\/td>\n<td>\n                                        -5&#8230;+40\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Storage temperature (\u00b0C)\n<\/td>\n<td>\n                                        -25&#8230;+70\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n                                        Instalaci\u00f3n\n<\/td>\n<td>\n                                        Tipo de conexi\u00f3n de terminal\n<\/td>\n<td>\n                                        Cable\/tablero tipo U\/tablero tipo pin\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Dimensiones del terminal superior\/inferior para el cable\n<\/td>\n<td>\n                                        25mm2 , 18-3\/18-2 AWG\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Dimensiones terminales superiores\/inferiores para la barra de bus\n<\/td>\n<td>\n                                        10\/16mm2 ,18-8 \/18-5AWG\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Torque de ajuste\n<\/td>\n<td>\n                                        2.5 N*m \/ 22 In-Ibs.\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Instalaci\u00f3n\n<\/td>\n<td>\n                                        On DIN rail EN 60715 (35mm)\n<\/td>\n<\/tr>\n<tr>\n<td>\n                                        Conexi\u00f3n\n<\/td>\n<td>\n                                        From top or bottom\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>The JC3RH-S RCD (residual current circuit breaker with overload protection) are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.<\/p>","protected":false},"featured_media":2715,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[184],"product_tag":[],"class_list":["post-2714","product","type-product","status-publish","has-post-thumbnail","product_cat-rccb-circuit-protection-products","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product\/2714","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/comments?post=2714"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/media\/2715"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/media?parent=2714"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_brand?post=2714"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_cat?post=2714"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_tag?post=2714"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}