{"id":2296,"date":"2026-07-30T11:27:51","date_gmt":"2026-07-30T03:27:51","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/cj19-changeover-capacitor-ac-contactor\/"},"modified":"2026-07-30T11:27:53","modified_gmt":"2026-07-30T03:27:53","slug":"cj19-changeover-capacitor-ac-contactor","status":"publish","type":"product","link":"https:\/\/w9-group.com\/es\/product\/cj19-changeover-capacitor-ac-contactor\/","title":{"rendered":"Contactor modular CJ19 Condensador de cambio Contactor de contacto Ac"},"content":{"rendered":"<h2>\nIntroduction<br \/>\n<\/h2>\n<p>CJ19 Series changeover capacitor contactor is especially used for low voltage shunt capacitor switching. And it widely used in reactive power compensation equipment in which AC 50HZ, voltage 380V, inrush current system in the contactor can decrease shock to capacitor and lower switching overvaluation while breaking a circuit.Moreover, It can replace transfer device which are composed of one contractor and three current limiting reactors, small, light, joins convenient and reliable, high capacity of turning on\/off.<br \/>These series\u00a0contactor \u00a0conforms to IEC60947-4-1 standard.<\/p>\n<p>CJ19 series AC Contactor is suitable for using in the circuits the rated voltage up to 400V AC 50Hz or 60Hz. CJ19 is used to combine with low voltage reactive power compensators or cut off low voltage shunt capacitor. CJ19 series AC Contactor has restraining device to effectively decrease impact caused by inrush transient current when switch on or over voltage when switch off.<\/p>\n<p><\/p>\n<h2>\nProduct Description<br \/>\n<\/h2>\n<p>Normal Running And Installation\u00a0Conditions:<\/p>\n<p>1. Ambient air temperature: -5\u2103 to +40\u2103.\u00a0 The average value within 24 hours should not exceed +35\u00b0C to ensure optimal performance and service life of the equipment.<br \/>\n2. Altitude: The equipment is suitable for installation below an altitude of 2000m to ensure its adaptability to various geographical locations.<br \/>\n3. Atmospheric conditions: In an environment with a temperature of 40\u00b0C, the relative humidity of the atmosphere should not exceed 50%. However, at lower temperatures, higher relative humidity may be allowed. The maximum monthly relative humidity should not exceed 90%, and special measures should be taken to prevent the occurrence of condensation to ensure the reliability and durability of the equipment under different atmospheric conditions.<br \/>\n4. Pollution level: The equipment is designed to operate effectively in Level 3 pollution environments, demonstrating its recovery capabilities in moderately polluted environments.<br \/>\n5. Installation category: The installation category is designated as III, which indicates that the equipment is suitable for fixed installation and ensures its stability and reliability in various applications.<br \/>\n6. Installation conditions: The inclination between the mounting surface and the vertical surface should not exceed II, ensuring correct installation and alignment for optimal performance and safety.<br \/>\n7. Shock Impact: The product should be installed and used in places where it may be subject to frequent vibrations and shocks, highlighting its sturdy structure and ability to withstand challenging working conditions.<\/p>\n<p>The most important features<\/p>\n<p>1. The contactor adopts a direct-acting double breakpoint structure design to ensure efficient and reliable operation. Its sensitive action mechanism is easy to inspect by hand and its compact structure makes it easy to replace contacts, minimizing downtime and maintenance workload.<br \/>\n2. The terminal block is protected by a cover to prevent accidental contact and ensure that connections are properly insulated, improving safety and reliability.<br \/>\n3. A variety of installation methods are provided. The contactor can be installed with screws or on a 35\/75mm standard rail. The deployment is flexible and can meet various installation requirements.<br \/>\n4. The contactor complies with the IEC60947-4-1 standard, ensuring that its performance, safety and quality comply with international standards, giving users confidence in its reliability and suitability for a variety of applications.<\/p>\n<table>\n<tbody>\n<tr>\n<td>Items<\/td>\n<td>CJ19-25<\/td>\n<td>CJ19-32<\/td>\n<td>CJ19-43<\/td>\n<td>CJ19-63<\/td>\n<td>CJ19-95<\/td>\n<td>CJ19-115<\/td>\n<td>CJ19-150<\/td>\n<td>CJ19-170<\/td>\n<\/tr>\n<tr>\n<td>Controllable capacitor\u00a0\u00a0 220V<\/td>\n<td>6<\/td>\n<td>9<\/td>\n<td>10<\/td>\n<td>15<\/td>\n<td>28.8(240V\uff09<\/td>\n<td>34.(240V\uff09<\/td>\n<td>46(240V\uff09<\/td>\n<td>52(240V\uff09<\/td>\n<\/tr>\n<tr>\n<td>Capacity\u00a0\u00a0 380V<\/td>\n<td>12<\/td>\n<td>18<\/td>\n<td>20<\/td>\n<td>30<\/td>\n<td>50(400V\uff09<\/td>\n<td>60(400V\uff09<\/td>\n<td>80(400V<\/td>\n<td>90(400V\uff09<\/td>\n<\/tr>\n<tr>\n<td>Rated 1solation<br \/>\nVoltage Ui V<\/td>\n<td colspan=\"5\">500<\/td>\n<td colspan=\"3\">690<\/td>\n<\/tr>\n<tr>\n<td>Rated Operational<br \/>\nVoltage Ue V<\/td>\n<td colspan=\"8\">220\/240+ 380\/400<\/td>\n<\/tr>\n<tr>\n<td>Conventional thermal current 1th A<\/td>\n<td>25<\/td>\n<td>32<\/td>\n<td>43<\/td>\n<td>63<\/td>\n<td>95<\/td>\n<td>200<\/td>\n<td>200<\/td>\n<td>275<\/td>\n<\/tr>\n<tr>\n<td>Rated Operational current 1eA (380V\uff09<\/td>\n<td>17<\/td>\n<td>23<\/td>\n<td>29<\/td>\n<td>43<\/td>\n<td>72.2 (400V\uff09<\/td>\n<td>87 (400V\uff09<\/td>\n<td>115(400V\uff09<\/td>\n<td>130(400V\uff09<\/td>\n<\/tr>\n<tr>\n<td>Restrained surge capacity<\/td>\n<td colspan=\"8\">20\u00a0 1e<\/td>\n<\/tr>\n<tr>\n<td>Controlled power voltage<\/td>\n<td>110\u00a0\u00a0 127\u00a0\u00a0 220\u00a0\u00a0 380<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Auxiliary contact<\/td>\n<td>AC.15: 360VA DC.13: 33W 1th:10A<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Operating Frequency cycles\/h<\/td>\n<td>120<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Electrical durability 104<\/td>\n<td colspan=\"5\">10<\/td>\n<td colspan=\"3\"><\/td>\n<\/tr>\n<tr>\n<td>Mechanical durability 104<\/td>\n<td colspan=\"8\">100<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>Amax<\/td>\n<td>Bmax<\/td>\n<td>Cmax<\/td>\n<td>Dmax<\/td>\n<td>E<\/td>\n<td>F<\/td>\n<td>Note<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u00a0\u00a0\u00a0\u00a0 CJ19-25<\/td>\n<td>80<\/td>\n<td>47<\/td>\n<td>124<\/td>\n<td>76<\/td>\n<td>34\/35<\/td>\n<td>50\/60<\/td>\n<td>Not only fixed by screws but also could<br \/>\nbe fixed with 35mm din rail<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u00a0\u00a0\u00a0\u00a0 CJ19-32<\/td>\n<td>90<\/td>\n<td>58<\/td>\n<td>132<\/td>\n<td>86<\/td>\n<td>40<\/td>\n<td>48<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u00a0\u00a0\u00a0\u00a0 CJ19-43<\/td>\n<td>90<\/td>\n<td>58<\/td>\n<td>136<\/td>\n<td>86<\/td>\n<td>40<\/td>\n<td>48<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u00a0\u00a0\u00a0\u00a0 CJ19-63<\/td>\n<td>132<\/td>\n<td>79<\/td>\n<td>150<\/td>\n<td>.<\/td>\n<td>.<\/td>\n<td>.<\/td>\n<td>Not only fixed by screws but also could<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u00a0\u00a0\u00a0\u00a0 CJ19-95<\/td>\n<td>135<\/td>\n<td>87<\/td>\n<td>158<\/td>\n<td>.<\/td>\n<td>.<\/td>\n<td>.<\/td>\n<td>be fixed with 35mm and 75mm din rail<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u00a0\u00a0\u00a0\u00a0 CJ19-115<\/td>\n<td>200<\/td>\n<td>120<\/td>\n<td>192<\/td>\n<td>155<\/td>\n<td><\/td>\n<td><\/td>\n<td>115(400V\uff09<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u00a0\u00a0\u00a0\u00a0 CJ19-150<\/td>\n<td>200<\/td>\n<td>120<\/td>\n<td>192<\/td>\n<td>155<\/td>\n<td><\/td>\n<td><\/td>\n<td>Not only fixed by screws but also could<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u00a0\u00a0\u00a0\u00a0 CJ19-170<\/td>\n<td>200<\/td>\n<td>120<\/td>\n<td>192<\/td>\n<td>155<\/td>\n<td><\/td>\n<td><\/td>\n<td>be fixed with two 35mm din rail<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\">6. wiring and installation<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\">6.1 The connection terminals are protected through insulation cover+ which is reliable and secure for installation and operation:<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\">6.2 For CJ19.25\u03bb43+ screws are available for installation+ as well as the D1N rail:<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\">\u00a0\u00a0\u00a0\u00a0 for CJ19.63\u03bb95+ 35mm or 75mm standard rail are available for installation.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\">for CJ19.115\u03bb170+ screws are available for installation+ as well as two 35mm D1N rail.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/cj19-changeover-capacitor-ac-contactor-detail-01.webp\" alt=\"Modular Contactor CJ19 Changeover capacitor Ac contactor detail image 1\" loading=\"lazy\"><\/p>","protected":false},"excerpt":{"rendered":"<p>CJ19 series switching capacitor contactor are used to switch low voltage shunt capacitors. They are widely used in reactive power compensation equipment with 380V 50hz.1. Used to switch low voltage shunt capacitor2. Widely used in reactive power compensation equipment with 380V 50hz3. With a device to restrain inrush current, effectively reduce the impact of Closing inrush current on the capacitor4. Small size, light weight, strong on-off capacity and easy installation5. Specification: 25A 32A 43A 63A 85A 95A<\/p>","protected":false},"featured_media":2297,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[76],"product_tag":[],"class_list":["post-2296","product","type-product","status-publish","has-post-thumbnail","product_cat-modular-contactor","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product\/2296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/comments?post=2296"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/media\/2297"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/media?parent=2296"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_brand?post=2296"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_cat?post=2296"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_tag?post=2296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}