{"id":2260,"date":"2026-07-30T11:27:36","date_gmt":"2026-07-30T03:27:36","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/jch2-125-main-switch-isolator-100a-125a\/"},"modified":"2026-07-30T11:27:39","modified_gmt":"2026-07-30T03:27:39","slug":"jch2-125-main-switch-isolator-100a-125a","status":"publish","type":"product","link":"https:\/\/w9-group.com\/es\/product\/jch2-125-main-switch-isolator-100a-125a\/","title":{"rendered":"Lsolating Switch JCH2-125 Main Switch Isolator 100A 125A"},"content":{"rendered":"<h2>\nIntroduction<br \/>\n<\/h2>\n<p>JCH2-125 Main switch isolator is designed to employ the main switch that may simultaneously sever the connection between the live and neutral wires.<br \/>JCH2-125 main switch that is also a switch disconnector which can be used as an Isolator, and can be used for residential and light commercial applications. The rate current is up to 125A. Rate current is available in 40A, 63A, 80A, 100A, 125A<br \/>JCH2-125 Main switch is available in 1 pole, 2 pole, 3 pole and 4 Pole. The rated frequency is 50\/60Hz. The rated impulse withstand voltage is 4000V. Rated short circuit withstand current lcw: 12le, t=0.1s. Rated making and breaking capacity: 3le, 1.05Ue, COS\u00d8=0.65. IP20 rated.<br \/>JCH2-125 Isolator has a green \/ red indication on the handle giving positive contact indication.Positive contact indicator: Green visible window indicates a 4mm contact gap.<br \/>JCH2-125 Isolator is 35mm din rail mounted, easy for installation. It is compatible with Pin type \/ fork type standard busbars. It is Ideal for use where local isolation is required.<br \/>JCH2-125 Isolator is a main switch only, without overload protection. It works to connect to cut off the load circuit.When it works as main switch, it may also trip when some of it&#8217;s sub-circuit faulty. In such situation, it functions as main switch to function as earlier circuit protection.<br \/>JCH2-125 Main switch isolator comply with IEC60947-3, EN60947-3<\/p>\n<p><\/p>\n<h2>\nProduct Description<br \/>\n<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jch2-125-main-switch-isolator-100a-125a-product-1-detail-01.webp\" alt=\"Lsolating Switch JCH2-125 Main Switch Isolator 100A 125A detail image 1\" loading=\"lazy\"><\/p>\n<h3>Main Features<\/h3>\n<p>\u25cf Rated current: 40A, 63A, 80A, 100A, 125A, providing a variety of options to adapt to various electrical load requirements.<\/p>\n<p>\u25cf Usage type: AC-22A type, indicating the intended use of the isolating switch, that is, the type of load and duty cycle it can handle.<\/p>\n<p>\u25cf Rated short circuit withstand current lcw: 12le, t=0.1s, ensuring robust protection and safety during short circuit.<\/p>\n<p>\u25cf Rated short-circuit making capacity 1cm: 20le, t=0.1s, proving the ability of the isolating switch to handle short-circuit situations.<\/p>\n<p>\u25cf Rated making and breaking capacity: 3le, 1.05Ue, COS\u00d8=0.65, providing information on the making and breaking circuit performance of the isolating switch.<\/p>\n<p>\u25cf Insulation voltage Ui: 690V, indicating the highest voltage at which the isolation switch can operate safely.<\/p>\n<p>\u25cf Rated impulse withstand voltage Uimp: 4000V, ensuring reliable performance under impulse voltage conditions.<\/p>\n<p>\u25cf IP rating: IP20 rating, providing protection against solid objects and limited protection against water.<\/p>\n<p>\u25cf Current limiting level 3 indicates the ability of the isolating switch to limit the fault current.<\/p>\n<p>\u25cf Contact position indicator red-green, provides visual indication of the contact position of the isolating switch to enhance safety and convenience.<\/p>\n<p>\u25cf Available in 1-pole, 2-pole, 3-pole and 4-pole configurations to meet different installation requirements and electrical settings.<\/p>\n<p>\u25cf Compatible with PIN or Fork type standard busbars, providing flexibility and compatibility with different busbar types.<\/p>\n<p>\u25cf Ability to lock equipment in the &#8220;ON&#8221; or &#8220;OFF&#8221; position using an equipment lock or padlock, providing additional security and control over the operation of the disconnect switch.<\/p>\n<p>\u25cf Comply with IEC60947-3 and EN60947-3 to ensure that electrical equipment complies with international standards and regulations, ensuring reliability and safety.<\/p>\n<table>\n<tbody>\n<tr>\n<td>Product code<\/td>\n<td colspan=\"4\">JCH2-\u00a0125<\/td>\n<\/tr>\n<tr>\n<td>Pole<\/td>\n<td>1\u00a0Pole<\/td>\n<td>2\u00a0Pole<\/td>\n<td>3\u00a0Pole<\/td>\n<td>4 Pole<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">Standard<\/td>\n<td colspan=\"2\">IEC\u00a060947-3\u00a0, EN\u00a060947-3<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"12\">\n<p>Electrical \u00a0features<\/p>\n<\/td>\n<td colspan=\"2\">Rated\u00a0\u00a0current\u00a0\u00a0In\u00a0\u00a0\u00a0(A)<\/td>\n<td colspan=\"2\">32\u00a0,40\u00a0,50\u00a0,63\u00a0,80\u00a0,\u00a0100\u00a0,\u00a0125<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Poles<\/td>\n<td colspan=\"2\">1P\u00a0, 2P\u00a0,\u00a03P\u00a0, 4P<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated\u00a0\u00a0voltage\u00a0\u00a0Ue\u00a0(V)<\/td>\n<td colspan=\"2\">230\/400~\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0240\/415<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Insulation\u00a0\u00a0voltage\u00a0\u00a0Ui\u00a0\u00a0\u00a0(V)<\/td>\n<td colspan=\"2\">500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated \u00a0frequency<\/td>\n<td colspan=\"2\">50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated\u00a0impulse\u00a0withstand\u00a0voltage(1\u00a0.2\/50) Uimp\u00a0(V)<\/td>\n<td colspan=\"2\">4000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated short-time withstand current lcw<\/td>\n<td colspan=\"2\">12le\u00a0,\u00a01s<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated making and breaking capacity<\/td>\n<td colspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated short circuit making capacity<\/td>\n<td colspan=\"2\">20le\u00a0, t=0.\u00a01s<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Dielectric test voltage at ind. Freq. for 5s<\/td>\n<td colspan=\"2\">2kV<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Pollution degree<\/td>\n<td colspan=\"2\">2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Uilization category<\/td>\n<td colspan=\"2\">AC-22A<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\">Mechanicalfeatures<\/td>\n<td colspan=\"2\">Electrical\u00a0\u00a0life<\/td>\n<td colspan=\"2\">1500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mechanical\u00a0\u00a0life<\/td>\n<td colspan=\"2\">8500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Contact \u00a0position\u00a0\u00a0indicator<\/td>\n<td colspan=\"2\">Yes<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Protection \u00a0degree<\/td>\n<td colspan=\"2\">IP 20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Reference \u00a0temperature \u00a0for \u00a0setting \u00a0of \u00a0thermal \u00a0element(\u2103)<\/td>\n<td colspan=\"2\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ambient\u00a0\u00a0temperature\u00a0\u00a0\u00a0(with\u00a0\u00a0daily\u00a0\u00a0average\u00a0\u00a0\u226435\u2103)<\/td>\n<td colspan=\"2\">-5.\u00a0.\u00a0.+40\u00a0\u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Storage\u00a0\u00a0temperation\u00a0\u00a0\u00a0(\u2103)<\/td>\n<td colspan=\"2\">-25&#8230;+70\u00a0\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">Installation<\/td>\n<td colspan=\"2\">Terminal \u00a0connection\u00a0\u00a0type<\/td>\n<td colspan=\"2\">Cable\/U-type \u00a0busbar\/Pin-type \u00a0busbar<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Terminal \u00a0size \u00a0top\/bottom \u00a0for \u00a0cable<\/td>\n<td colspan=\"2\">50mm\u00b2\u00a0\/\u00a018-\u00a01\/0\u00a0AWG<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Terminal \u00a0size \u00a0top\/bottom \u00a0for busbar<\/td>\n<td colspan=\"2\">35mm\u00b2\u00a0\u00a0\u00a0\/\u00a018-2 \u00a0AWG<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Tightening \u00a0torque<\/td>\n<td colspan=\"2\">2.5\u00a0\u00a0N*m \u00a0\u00a0\u00a0\/ \u00a022\u00a0\u00a0In-Ibs.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mounting<\/td>\n<td colspan=\"2\">On\u00a0\u00a0DIN\u00a0\u00a0rail\u00a0\u00a0EN\u00a0\u00a060715 \u00a0\u00a0(35mm)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td colspan=\"2\">From \u00a0top\u00a0\u00a0and\u00a0\u00a0bottom<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Technical Data<\/h3>\n<p>\u25cf Standards: IEC60947-3, EN60947-3, ensuring compliance with international standards for electrical equipment and ensuring reliability and safety.<\/p>\n<p>\u25cf Rated current: 32A, 40A, 50A, 63A, 80A, 100A, 125A, providing a variety of options to adapt to various electrical load requirements.<\/p>\n<p>\u25cf Number of poles: 1P, 2P, 3P, 4P to meet different installation requirements and electrical settings.<\/p>\n<p>\u25cf Rated voltage Ue: 230V\/400V\uff5e240V\/415V, indicating the rated operating voltage range of the isolating switch.<\/p>\n<p>\u25cf Insulation voltage Ui: 500V, ensuring safe operation under specified voltage conditions.<\/p>\n<p>\u25cf Rated frequency: 50\/60Hz, indicating the rated frequency of the isolating switch action.<\/p>\n<p>\u25cf Rated impulse withstand voltage (1.2\/50) Uimp: 4000V, ensuring reliable performance under impulse voltage conditions.<\/p>\n<p>\u25cf Rated short-time withstand current lcw: 12le, 1s, providing strong protection and safety in the event of a short circuit.<\/p>\n<p>\u25cf Rated making and breaking capacity: 3le, 1.05Ue, cos\u03c6=0.65, providing information on the making and breaking circuit performance of the isolating switch.<\/p>\n<p>\u25cf Rated short-circuit making capacity: 20le, t=0.1s, indicating the ability of the isolating switch to handle short-circuit situations.<\/p>\n<p>\u25cf Insulation test voltage. frequency. Lasts 5 seconds: 2kV, ensuring electrical insulation and safety under specified test conditions.<\/p>\n<p>\u25cf Pollution level: Level 2, indicating the degree of pollution that the isolation switch can withstand while maintaining safe and reliable operation.<\/p>\n<p>\u25cf Mechanical life: 8500 times, indicating the number of mechanical operations that the isolation switch can withstand.<\/p>\n<p>\u25cf Electrical life: 1500 times, indicating the number of electrical operations that the isolation switch can withstand.<\/p>\n<p>\u25cf Protection level: IP20, providing protection against solid objects and limited waterproof protection.<\/p>\n<p>\u25cf Ambient temperature (daily average \u226435\u2103): -5\u2103\uff5e+40\u2103, indicating the ambient temperature range in which the isolation switch can effectively operate.<\/p>\n<p>\u25cf Contact position indicator: green = closed, red = open, provides visual indication of isolation switch contact position to enhance safety and convenience.<\/p>\n<p>\u25cf Terminal connection method: Cable\/Pin type busbar, flexible and compatible with different terminal connection methods.<\/p>\n<p>\u25cf Installation method: Installed on DIN rail EN 60715 (35mm) through a quick clamp device, providing a standardized and convenient installation method.<\/p>\n<p>\u25cf Recommended torque: 2.5Nm, ensure the isolation switch is installed and operated correctly.<\/p>\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>Standard<\/td>\n<td>\u00a0IEC\/EN 60947-3<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"11\">\n<p>Electrical features<\/p>\n<\/td>\n<td>Rated current In (A)<\/td>\n<td>32,40,50,63,80,100,125<\/td>\n<\/tr>\n<tr>\n<td>Poles<\/td>\n<td>1P, \u00a02P, 3P, 4P<\/td>\n<\/tr>\n<tr>\n<td>Rated voltage Ue(V)<\/td>\n<td>230\/400~240\/415<\/td>\n<\/tr>\n<tr>\n<td>Insulation voltage Ui (V)<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>Rated frequency<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>Rated impulse withstand voltage(1.2\/50) Uimp (V)<\/td>\n<td>4,000<\/td>\n<\/tr>\n<tr>\n<td>Rated short-time withstand current lcw<\/td>\n<td>12le, 1s<\/td>\n<\/tr>\n<tr>\n<td>Rated making and breaking capacity<\/td>\n<td>3le, 1.05Ue, cos\u03c6=0.65<\/td>\n<\/tr>\n<tr>\n<td>Rated short circuit making capacity<\/td>\n<td>20le, t=0.1s<\/td>\n<\/tr>\n<tr>\n<td>Dielectric test voltage at ind. Freq. for 5s<\/td>\n<td>2kV<\/td>\n<\/tr>\n<tr>\n<td>Pollution degree<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Uilization category<\/td>\n<td>AC-22A<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n<p>Mechanical features<\/p>\n<\/td>\n<td>Electrical life<\/td>\n<td>1500<\/td>\n<\/tr>\n<tr>\n<td>Mechanical life<\/td>\n<td>8500<\/td>\n<\/tr>\n<tr>\n<td>Contact position indicator<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Protection degree<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Ambient temperature (with daily average \u226435\u2103)<\/td>\n<td>-5\u2026+40<\/td>\n<\/tr>\n<tr>\n<td>Storage temperation (\u2103)<\/td>\n<td>-25\u2026+70<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">Installation<\/td>\n<td>Terminal connection type<\/td>\n<td>Cable\/U-type busbar\/Pin-type busbar<\/td>\n<\/tr>\n<tr>\n<td>Terminal size top\/bottom for cable<\/td>\n<td>\n<p>50mm2 \u00a0\/ 18-1\/0 AWG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Terminal size top\/bottom for Busbar<\/td>\n<td>\n<p>35mm2 \u00a0\/ 18-2 AWG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Tightening torque<\/td>\n<td>\n<p>2.5 N*m \u00a0\/ \u00a022 In-Ibs.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Mounting<\/td>\n<td>On DIN rail EN 60715 (35mm) by means of fast clip device<\/td>\n<\/tr>\n<tr>\n<td>Connection<\/td>\n<td>From top and bottom<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jch2-125-main-switch-isolator-100a-125a-detail-03.webp\" alt=\"Lsolating Switch JCH2-125 Main Switch Isolator 100A 125A detail image 2\" loading=\"lazy\"><\/p>\n<p>\u00a0Q1: I wonder if you accept small orders?<br \/>\n\u00a0A1: Don&#8217;t worry. Welcome to contact us. In order to accommodate different order sizes and provide customers with greater flexibility, we are happy to accept small orders and are committed to providing the same level of quality and service.<br \/>\n<br \/>\n\u00a0Q2: Can you send the product to my country?<br \/>\n\u00a0A2: Of course, we can. If you don&#8217;t have your own freight forwarder, we can help you arrange shipping to your country, ensuring a smooth and hassle-free shipping process.<br \/>\n<br \/>\n\u00a0Q3: Can you do OEM for me?<br \/>\n\u00a0A3: We accept all OEM orders. Simply contact us with your design specifications and we will work closely with you to provide competitive pricing and produce samples in time for your approval.<br \/>\n<br \/>\n\u00a0Q4: What are your payment terms?<br \/>\n\u00a0A4: We provide flexible payment terms, including T\/T, L\/C at sight, 30% deposit is required in advance, and the remaining 70% is paid against a copy of the bill of lading (B\/L) to ensure a safe and transparent transaction process.<br \/>\n<br \/>\n\u00a0Q5: How can I place an order?<br \/>\n\u00a0A5: To place an order, simply sign the Proforma Invoice (PI) and submit the required deposit. Once received, we will arrange production in time. Upon completion, we will provide you with a copy of the bill of lading for payment and upon receipt, ship the goods to you.<br \/>\n<br \/>\n\u00a0Q6: When can I get the quotation?<br \/>\n\u00a0A6: We strive to provide timely and efficient service. Normally we aim to provide you with a quote within 24 hours of receiving your inquiry. If your request is urgent, please feel free to call us or indicate the urgency in your email and we will prioritize your inquiry accordingly.<\/p>","protected":false},"excerpt":{"rendered":"<p>JCH2-125 series Main Switch is a switch disconnector which can be used as an Isolator, and can be used for residential and light commercial applications.With plastic lockWith contact indicatorRated current up to 125A1 Pole, 2 Pole, 3 Pole , 4 Pole are availableComply with IEC 60947-3<\/p>","protected":false},"featured_media":2276,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[77],"product_tag":[],"class_list":["post-2260","product","type-product","status-publish","has-post-thumbnail","product_cat-lsolating-switch","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product\/2260","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/comments?post=2260"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/media\/2276"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/media?parent=2260"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_brand?post=2260"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_cat?post=2260"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_tag?post=2260"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}