{"id":2250,"date":"2026-07-30T11:27:19","date_gmt":"2026-07-30T03:27:19","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/jcrd4-125-4-pole-rcd-residual-current-circuit-breaker-type-ac-or-type-a-rccb\/"},"modified":"2026-07-30T11:27:20","modified_gmt":"2026-07-30T03:27:20","slug":"jcrd4-125-4-pole-rcd-residual-current-circuit-breaker-type-ac-or-type-a-rccb","status":"publish","type":"product","link":"https:\/\/w9-group.com\/es\/product\/jcrd4-125-4-pole-rcd-residual-current-circuit-breaker-type-ac-or-type-a-rccb\/","title":{"rendered":"MCCB circuit breaker RCD residual current circuit breaker JCRD4-125 4 Pole Type AC or Type A RCCB"},"content":{"rendered":"<h2>\nIntroduction<br \/>\n<\/h2>\n<p>JCRD4-125 4 pole RCDs may be used to provide earth fault protection on 3 phase, 3 wire systems, as the current balance mechanism does not require a neutral to be connected in order to operate effectively.<\/p>\n<p>JCRD4-125 RCDs must never be used as the sole method of direct contact protection, but are invaluable in providing supplementary protection in high risk environments where damage may occur.<\/p>\n<p>However W9 GROUP JCRD4-125 4 pole RCDs do, ideally, require a neutral conductor to be provided on the supply side of the RCD in order to ensure that the test circuit operates satisfactorily. Where connection of a neutral supply is not possible, then an alternative method of ensuring that the test button is operational is to fit a suitably rated resistor between the load side neutral pole and a phase pole not associated with the normal test button operation.<\/p>\n<p>JCRD4-125 4 pole RCD is available in ac type and A type. AC type RCDs are only sensitive to sinusoidal type fault currents. A type RCDs, on the other hand, are sensitive to both sinusoidal currents and \u201cunidirectional pulsed\u201d currents, which may be present, for example, in systems with electronic devices for rectifying the current. These devices are capable of generating pulsed shape fault currents with continuous components that an AC type RCD is unable to recognize<\/p>\n<p>JCRD4-125 RCD provides protection against earth faults occurring in equipment and reduces the effects of electric shock on human beings and thus saves lives.<\/p>\n<p>JCRD4-125 RCD measures the current flowing in the live and neutral cables and if there is an imbalance, that is current flowing to earth above the RCD sensitivity, the RCD will trip and cut off the supply.<\/p>\n<p>JCRD4-125 RCDs incorporate a filtering device to provide protection against transient surges in the supply to the unit, thus reducing the occurrence of unwanted tripping<\/p>\n<h2>\nProduct Description<br \/>\n<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcrd4-125-4-pole-rcd-residual-current-circuit-breaker-type-ac-or-type-a-detail-01.webp\" alt=\"MCCB circuit breaker RCD residual current circuit breaker JCRD4-125 4 Pole Type AC or Type A RCCB detail image 1\" loading=\"lazy\"><\/p>\n<h3>Main Features<\/h3>\n<p>\u25cfElectromagnetic type, reliable operation<br \/>\n\u25cfLeakage protection to prevent the risk of electric shock<br \/>\n\u25cfMultiple options to suit various specifications<br \/>\n\u25cfMinimize the risk of uninterruptible power supply tripping unexpectedly<br \/>\n\u25cfClear indication of contact status for easy monitoring<br \/>\n\u25cfHigh level of accidental electric shock protection<br \/>\n\u25cfBreaking capacity up to 6kA to handle high fault currents<br \/>\n\u25cfCurrent rating options up to 100A including 25A, 32A, 40A, 63A, 80A and 100A<br \/>\n\u25cf30mA, 100mA and 300mA trip sensitivities provide customized protection<br \/>\n\u25cfAvailable in Type A or AC to achieve different fault current detection functions<br \/>\n\u25cfCentral trolley position provides clear indication of ground faults<br \/>\n\u25cf35mm DIN rail mounting for easy installation<br \/>\n\u25cfFlexible wiring from top or bottom for easy installation<br \/>\n\u25cfComplies with IEC 61008-1 and EN61008-1 quality assurance<br \/>\n\u25cfSuitable for a wide range of applications including residential, commercial and light industrial uses<\/p>\n<table>\n<tbody>\n<tr>\n<td>RCD<\/td>\n<td>Types of Load<\/td>\n<\/tr>\n<tr>\n<td>Type AC<\/td>\n<td>Resistive, capacitive, inductive loadsImmersion heater, oven \/ hob with resistive heating elements, electric shower, tungsten \/ halogen lighting<\/td>\n<\/tr>\n<tr>\n<td>Type A<\/td>\n<td>Single phase with electronic componentsSingle phase inverters, class 1 IT &amp; multimedia equipment, power supplies for class 2 equipment, appliances such as washing machines, lighting controls, induction hobs &amp; EV charging<\/td>\n<\/tr>\n<tr>\n<td>Type F<\/td>\n<td>Frequency controlled equipmentAppliances containing synchronous motors, some class 1 power tools, some air conditioning controllers using variable frequency speed drives<\/td>\n<\/tr>\n<tr>\n<td>Type B<\/td>\n<td>Three phase electronic equipmentInverters for speed control, ups, EV charging where DC fault current is &gt;6mA, PV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcrd4-125-4-pole-rcd-residual-current-circuit-breaker-type-ac-or-type-a-detail-02.webp\" alt=\"MCCB circuit breaker RCD residual current circuit breaker JCRD4-125 4 Pole Type AC or Type A RCCB detail image 2\" loading=\"lazy\"><\/p>\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>Standard<\/td>\n<td>IEC61008-1 ,\u00a0 EN61008-1<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"12\">Electrical<br \/>\nfeatures<\/td>\n<td>Rated current In (A)<\/td>\n<td>\u00a025, 40, 50, 63, 80, 100, 125<\/td>\n<\/tr>\n<tr>\n<td>Type<\/td>\n<td>Electromagnetic<\/td>\n<\/tr>\n<tr>\n<td>Type (wave form of the earth leakage sensed)<\/td>\n<td>AC, A, AC-G, A-G, AC-S and A-S are available<\/td>\n<\/tr>\n<tr>\n<td>Poles<\/td>\n<td>4 Pole<\/td>\n<\/tr>\n<tr>\n<td>Rated voltage Ue(V)<\/td>\n<td>400\/415<\/td>\n<\/tr>\n<tr>\n<td>Rated sensitivity I\u25b3n<\/td>\n<td>30mA,100mA,300mA are available<\/td>\n<\/tr>\n<tr>\n<td>Insulation voltage Ui (V)<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>Rated frequency<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>Rated breaking capacity<\/td>\n<td>6kA<\/td>\n<\/tr>\n<tr>\n<td>Rated impulse withstand voltage(1.2\/50) Uimp (V)<\/td>\n<td>6000<\/td>\n<\/tr>\n<tr>\n<td>Dielectric test voltage at ind. Freq. for 1 min<\/td>\n<td>2.5kV<\/td>\n<\/tr>\n<tr>\n<td>Pollution degree<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\">Mechanical<br \/>\nfeatures<\/td>\n<td>Electrical life<\/td>\n<td>2, 000<\/td>\n<\/tr>\n<tr>\n<td>Mechanical life<\/td>\n<td>2, 000<\/td>\n<\/tr>\n<tr>\n<td>Contact position indicator<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Protection degree<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Reference temperature for setting of thermal element(\u2103)<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td>Ambient temperature (with daily average \u226435\u2103)<\/td>\n<td>-5&#8230;+40<\/td>\n<\/tr>\n<tr>\n<td>Storage temperation (\u2103)<\/td>\n<td>-25&#8230;+70<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">Installation<\/td>\n<td>Terminal connection type<\/td>\n<td>Cable\/U-type busbar\/Pin-type busbar<\/td>\n<\/tr>\n<tr>\n<td>Terminal size top\/bottom for cable<\/td>\n<td>25mm2\u00a0 , 18-3\/18-2 AWG<\/td>\n<\/tr>\n<tr>\n<td>Terminal size top\/bottom for Busbar<\/td>\n<td>10\/16mm2\u00a0\u00a0,18-8 \/18-5AWG<\/td>\n<\/tr>\n<tr>\n<td>Tightening torque<\/td>\n<td>2.5 N*m\u00a0 \/\u00a0 22 In-Ibs.<\/td>\n<\/tr>\n<tr>\n<td>Mounting<\/td>\n<td>On DIN rail EN 60715 (35mm) by means of fast clip device<\/td>\n<\/tr>\n<tr>\n<td>Connection<\/td>\n<td>From top or bottom<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>JCR4-125 are electrical safety devices designed to immediately switch off the supply of electricity when electricity leaking to earth is detected at harmful levels. They offer high levels of personal protection from electric shock.<\/p>","protected":false},"featured_media":2251,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[184],"product_tag":[],"class_list":["post-2250","product","type-product","status-publish","has-post-thumbnail","product_cat-rccb-circuit-protection-products","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product\/2250","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/comments?post=2250"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/media\/2251"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/media?parent=2250"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_brand?post=2250"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_cat?post=2250"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_tag?post=2250"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}