{"id":2143,"date":"2026-07-30T11:25:55","date_gmt":"2026-07-30T03:25:55","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-n-1-1-1-1-1\/"},"modified":"2026-07-30T11:25:57","modified_gmt":"2026-07-30T03:25:57","slug":"jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-n-1-1-1-1-1","status":"publish","type":"product","link":"https:\/\/w9-group.com\/es\/product\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-n-1-1-1-1-1\/","title":{"rendered":"RCBO single Module residual current circuit breaker with overload protection JCB2LE-40M 1P+N mini 6kA"},"content":{"rendered":"<h2>\nIntroduction<br \/>\n<\/h2>\n<p>JCB2LE-40M RCBO (residual current circuit breaker with overload protection) is designed for protection against short circuits, overloads and earth leakage in single phase installations. JCB2LE-40M RCBO is a combined RCCB and MCB in one unit providing earth leakage, overload and short circuit protection of domestic installations.<\/p>\n<p>JCB2LE-40M RCBO combine MCB and RCD protection, provides overload and short circuit protection in one unit. It makes this a perfect unit for use in caravan parks, marinas, leisure parks by allowing earth fault protection to be restricted to a single circuit \u2013 limiting nuisance tripping of many circuits.<\/p>\n<p>JCB2LE-40M rcbo provides combined residual current (earth leakage) protection and overload\/short circuit protection in a single device and may be used to replace an RCCB\/MCB combination. Movement characteristic of products can not be changed with outside mechanical tool;The operating organization has the free function to take off and buckle; Operate part can not be taken down from the shell outer of products, the shell can not influence the operating organization to work, the accessory group which replace the feelers pressure, should guarantee the feelers does not change while running.<\/p>\n<p><\/p>\n<p>JCB2LE-40M RCBO make you more safety.This RCBO with both disconnected neutral and phase guarantees its proper actuation against earth leakage faults even when the neutral and phase are wrongly connected. It automatically switches off the electrical circuit during the abnormal conditions of the network and faulty conditions to prevent damage. It has an energy limiting class 3, meaning the highest energy limiting performance to reduce risk of fire and other damage.<\/p>\n<p>JCB2LE-40M RCBO is very easy to install in the single phase distribution box, it is non Line \/ Load sensitive RCBO, its Installation flexibility with the choice of line connection either from top or bottom.<\/p>\n<p>JCB2LE-40M RCBO is the RCBO that has a width of 18 mm or 1-module housing and a short circuit capacity of 6kA. It is available in 6kA, type A, type AC, 30mA, 100mA with various current ratings from 6A to 40A.<\/p>\n<p>The JCB2LE-40M RCBOs (residual current circuit breaker with overload protection) are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses. It is highly advised to be used in installations that requires high level of protection such as bathrooms, hospitals, kindergartens, etc.<\/p>\n<p><\/p>\n<h2>\nProduct Description<br \/>\n<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-detail-01-5.webp\" alt=\"RCBO single Module residual current circuit breaker with overload protection JCB2LE-40M 1P+N mini 6kA detail image 1\" loading=\"lazy\"><\/p>\n<p>The most important features<\/p>\n<p>\u25cf Electronic type: RCBO utilizes electronic technology to provide advanced protection features.<br \/>\n\u25cf Leakage protection: Provide comprehensive leakage fault protection to improve safety.<br \/>\n\u25cf Overload and short-circuit protection: Ensure reliable overload and short-circuit protection to protect the electrical system.<br \/>\n\u25cf Non-Line\/Load Sensitive: Provides installation flexibility with choice of top or bottom line connections.<br \/>\n\u25cf Breaking capacity up to 6kA: Provides high breaking capacity and effectively handles electrical faults.<br \/>\n\u25cf Current ratings up to 40A: Available in a variety of current ratings, providing versatility for different applications.<br \/>\n\u25cf B-curve or C trip curve available: options for different trip characteristics to meet specific requirements.<br \/>\n\u25cf Trip sensitivity: Provides 30mA and 100mA trip sensitivity options to meet diverse needs.<br \/>\n\u25cf Compact and ultra-thin module design: efficient use of space, allowing multiple RCDs\/MCBs to be installed in a single housing.<br \/>\n\u25cf True bipolar circuit break: ensures complete isolation of faulty circuits for enhanced safety.<br \/>\n\u25cf Neutral pole switching: Reduce installation and debugging test time and improve efficiency.<br \/>\n\u25cf Insulation opening: facilitates busbar installation and simplifies the installation process.<br \/>\n\u25cf 35mm DIN rail mounting: Compatible with standard DIN rail mounting systems, easy to install.<br \/>\n\u25cf Compatible with various types of screwdrivers: it adopts combination head screws for easy installation and multi-function.<br \/>\n\u25cf Meet ESV additional testing and verification requirements: Meet additional testing and verification standards to enhance reliability.<br \/>\n\u25cf Comply with IEC 61009-1, EN61009-1: comply with international standards to ensure quality and safety compliance.<\/p>\n<p>\u00a0<br \/>\nTechnical Data<\/p>\n<p>\u25cf Standards: Compliant with IEC 61009-1 and EN61009-1, ensuring compliance with international safety and quality standards.<br \/>\n\u25cf Type: Utilizes electronic technology to achieve advanced protection functions.<br \/>\n\u25cf Type (detected ground leakage waveform): Available in Type A or AC options to meet specific application requirements.<br \/>\n\u25cf Number of poles: 1P+N configuration is used to effectively protect the circuit.<br \/>\n\u25cf Rated current: Available in multiple current ratings of 2A, 6A, 10A, 16A, 20A, 25A, 32A and 40A, providing versatility for different applications.<br \/>\n\u25cf Rated working voltage: supports 110V and 230V~ (1P + N) configuration, suitable for a variety of electrical systems.<br \/>\n\u25cf Rated sensitivity I\u25b3n: Provides 30mA and 100mA rated sensitivity options to meet different protection needs.<br \/>\n\u25cf Rated breaking capacity: Provides high breaking capacity of 6kA to effectively handle electrical faults.<br \/>\n\u25cf Insulation voltage: Provides 500V insulation voltage, safe and reliable.<br \/>\n\u25cf Rated frequency: supports rated frequency of 50\/60Hz, compatible with standard electrical systems.<br \/>\n\u25cf Rated pulse withstand voltage (1.2\/50): Provides a rated pulse withstand voltage of 6kV to enhance surge protection.<br \/>\n\u25cf Pollution level: The design pollution level is level 2, suitable for various environmental conditions.<br \/>\n\u25cf Thermomagnetic release characteristics: B-curve, C-curve and D-curve options are provided to meet specific application requirements.<br \/>\n\u25cf Mechanical life: Mechanical life of 20,000 times, ensuring long-term reliability and durability.<br \/>\n\u25cf Electrical Life: Provides 2000 cycles of electrical life, demonstrating consistent performance over time.<br \/>\n\u25cf Protection level: With IP20 protection level, it provides protection against solid objects and limited waterproof protection.<br \/>\n\u25cf Ambient temperature: Suitable to operate at ambient temperatures from -5\u00b0C to +40\u00b0C, adapting to different environments.<br \/>\n\u25cf Contact position indicator: Equipped with contact position indicator, green means OFF, red means ON, the status indication is clear at a glance.<br \/>\n\u25cf Terminal connection type: supports cable, U-shaped busbar, pin-type busbar connection, flexible installation.<br \/>\n\u25cf Installation: Easily mounts on DIN rail EN 60715 (35mm) using the quick clamp device, simplifying installation and ensuring a secure installation.<br \/>\n\u25cf Recommended torque: A recommended torque of 2.5Nm is provided to ensure correct installation and secure connection.<br \/>\n\u25cf Connection method: Flexible connection from top or bottom for easy installation and maintenance.<\/p>\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\n<p>Standard<\/p>\n<\/td>\n<td>\n<p>IEC61009-1 , \u00a0EN61009-1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"12\">\n<p>Electrical<\/p>\n<p>features<\/p>\n<\/td>\n<td>\n<p>Rated current In (A)<\/p>\n<\/td>\n<td>\n<p>6, 10, 16, 20, 25, 32, 40<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Type<\/p>\n<\/td>\n<td>\n<p>Electronic<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Type (wave form of the earth leakage sensed)<\/p>\n<\/td>\n<td>\n<p>A or AC are available<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Poles<\/p>\n<\/td>\n<td>\n<p>1P+N<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated voltage Ue(V)<\/p>\n<\/td>\n<td>\n<p>230\/240<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated sensitivity I\u25b3n<\/p>\n<\/td>\n<td>\n<p>30mA, 100mA,300mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation voltage Ui (V)<\/p>\n<\/td>\n<td>\n<p>500<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated frequency<\/p>\n<\/td>\n<td>\n<p>50\/60Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated breaking capacity<\/p>\n<\/td>\n<td>\n<p>6kA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated impulse withstand voltage(1.2\/50) Uimp (V)<\/p>\n<\/td>\n<td>\n<p>6000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pollution degree<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Thermo-magnetic release characteristic<\/p>\n<\/td>\n<td>\n<p>B, C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\">\n<p>Mechanical<\/p>\n<p>features<\/p>\n<\/td>\n<td>\n<p>Electrical life<\/p>\n<\/td>\n<td>\n<p>2, 000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Mechanical life<\/p>\n<\/td>\n<td>\n<p>20, 000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Contact position indicator<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Protection degree<\/p>\n<\/td>\n<td>\n<p>IP20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Reference temperature for setting of thermal element(\u2103)<\/p>\n<\/td>\n<td>\n<p>30<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Ambient temperature (with daily average \u226435\u2103)<\/p>\n<\/td>\n<td>\n<p>-5&#8230;+40<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Storage temperation (\u2103)<\/p>\n<\/td>\n<td>\n<p>-25&#8230;+70<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n<p>Installation<\/p>\n<\/td>\n<td>\n<p>Terminal connection type<\/p>\n<\/td>\n<td>\n<p>Cable\/Pin-type busbar<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Terminal size top\/bottom for cable<\/p>\n<\/td>\n<td>\n<p>16mm2 \u00a0\/ 18-5 AWG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Terminal size top\/bottom for Busbar<\/p>\n<\/td>\n<td>\n<p>10mm2 \u00a0\/ 18-8 AWG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tightening torque<\/p>\n<\/td>\n<td>\n<p>2.5 N*m \u00a0\/ \u00a022 In-Ibs.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Mounting<\/p>\n<\/td>\n<td>\n<p>On DIN rail EN 60715 (35mm) by means of fast clip device<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Connection<\/p>\n<\/td>\n<td>\n<p>From top or bottom are available<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-detail-02-5.webp\" alt=\"RCBO single Module residual current circuit breaker with overload protection JCB2LE-40M 1P+N mini 6kA detail image 2\" loading=\"lazy\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-detail-03-5.webp\" alt=\"RCBO single Module residual current circuit breaker with overload protection JCB2LE-40M 1P+N mini 6kA detail image 3\" loading=\"lazy\"><\/p>","protected":false},"excerpt":{"rendered":"<p>The JCB2LE-40M RCBOs (residual current circuit breaker with overload protection) are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.Exclusive design for your safety!Electronic TypeResidual current protectionOverload and short circuit protectionBreaking capacity 6kARated current up to 40A (available from 6A to 40A)Available in B Curve or C tripping curves.Tripping sensitivity: 30mA,100mAType A or Type AC are availableDouble pole switching for complete isolation of faulty circuitsNeutral pole switching significantly reduces the installation and commissioning test timeComplies with IEC 61009-1, EN61009-1<\/p>","protected":false},"featured_media":2144,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[78],"product_tag":[],"class_list":["post-2143","product","type-product","status-publish","has-post-thumbnail","product_cat-rcbo","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product\/2143","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/comments?post=2143"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/media\/2144"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/media?parent=2143"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_brand?post=2143"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_cat?post=2143"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_tag?post=2143"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}