{"id":1950,"date":"2026-07-30T11:23:55","date_gmt":"2026-07-30T03:23:55","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/wlm6-2000a-3300-3p-4p-wlm6-series-thermal-magnetic-type-breaker-400v-690v-2000-amp-3-4-poles-1-1-pro\/"},"modified":"2026-07-30T11:23:56","modified_gmt":"2026-07-30T03:23:56","slug":"wlm6-2000a-3300-3p-4p-wlm6-series-thermal-magnetic-type-breaker-400v-690v-2000-amp-3-4-poles-1-1-pro","status":"publish","type":"product","link":"https:\/\/w9-group.com\/es\/product\/wlm6-2000a-3300-3p-4p-wlm6-series-thermal-magnetic-type-breaker-400v-690v-2000-amp-3-4-poles-1-1-pro\/","title":{"rendered":"WLM7HU-400-3300 3P solar type Molded Case Circuit Breaker 800V mccb 800VAC\/1000VAC\/1140VAC 400A 3 Poles"},"content":{"rendered":"<h2>\nMCCB\u00a0Highlights<br \/>\n<\/h2>\n<p>Microprocessor releases<br \/>\nWide range of overload setting starting from 0.25In<br \/>\n\u00b7Neutral overload protection<br \/>\n\u00b7Short circuit setting with delay or instantaneous optiono Inbuilt Earth fault Protection<br \/>\n\u00b7Adjustable instantaneous Setting<br \/>\n\u00b7Thermal Memory with option of Defeat<br \/>\n\u00b7Provision for release testing<br \/>\n\u00b7Separate LEDs each for Overload,Short Circuit,Instantaneous and Earth fault Indication<\/p>\n<p><\/p>\n<h2>\nMain performance index of WLM7HU series circuit breaker<br \/>\n<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"10\">\nWLM7HU Moulded Case Circuit Breaker<\/td>\n<td colspan=\"3\">400<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated operating current In (A),40\u2103<\/td>\n<td colspan=\"4\">250-315-350-400<\/td>\n<\/tr>\n<tr><\/tr>\n<tr>\n<td colspan=\"10\">Rated insulation voltage Ui (V)<\/td>\n<td colspan=\"3\">1250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated impulse withstand voltage (kV)<\/td>\n<td colspan=\"3\">12<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Rated operational voltage Ue(V),AC 50\/60Hz<\/td>\n<td colspan=\"3\">415\/690\/800\/1000\/1140v\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Breaking capacity code<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">M<\/td>\n<td colspan=\"1\">H<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">Number of poles<\/td>\n<td colspan=\"5\">\n3P<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<td colspan=\"1\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC415V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC690V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">60<\/td>\n<td colspan=\"1\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"5\">\nRated ultimate<br \/>\nshort-circuit breaking<br \/>\ncapacity Icu(kA)\n<\/td>\n<td colspan=\"5\">AC800V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">50<\/td>\n<td colspan=\"1\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC1000V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">20<\/td>\n<td colspan=\"1\">25<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC1140V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">15<\/td>\n<td colspan=\"1\">20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC415V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC690V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">60<\/td>\n<td colspan=\"1\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">\nRated service breaking<br \/>\ncapacity Ics(kA)\n<\/td>\n<td colspan=\"5\">AC800V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">37.5<\/td>\n<td colspan=\"1\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC1000V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">15<\/td>\n<td colspan=\"1\">20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC1140V<\/td>\n<td colspan=\"1\">&#8211;<\/td>\n<td colspan=\"1\">15<\/td>\n<td colspan=\"1\">15<\/td>\n<\/tr>\n<tr><\/tr>\n<tr>\n<td colspan=\"10\">Standard<\/td>\n<td colspan=\"3\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Utilization category<\/td>\n<td colspan=\"3\">A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Ambient temperature<\/td>\n<td colspan=\"3\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Safety of insulation<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\">Arcing distance<\/td>\n<td colspan=\"3\">0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\nMechanical life<br \/>\n(CO recycle)\n<\/td>\n<td colspan=\"5\">Maintenance free<\/td>\n<td colspan=\"3\">15000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"1\">\nElectrical life<br \/>\n(CO recycle)\n<\/td>\n<td colspan=\"5\">Maintenance free<\/td>\n<td colspan=\"3\">1000-5000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Release units<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Distribution protection<\/td>\n<td colspan=\"5\">TM<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Mounting and connection<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Fixed<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Plug-in<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"3\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"2\">Draw-out\n<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Rear connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">DIN rail<\/td>\n<td colspan=\"5\">Front connection<\/td>\n<td colspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Dimension<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" rowspan=\"3\">\nDimension (mm)<br \/>\nW\u00d7H\u00d7D\n<\/td>\n<td colspan=\"5\">Width<\/td>\n<td colspan=\"3\">150<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Height<\/td>\n<td colspan=\"3\">257<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Depth<\/td>\n<td colspan=\"3\">125.8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"13\">Weight<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Weight(kg)\/Fixed<\/td>\n<td colspan=\"5\">3P<\/td>\n<td colspan=\"3\">5.8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\nOverall and installation dimensions of circuit breaker<br \/>\n<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/wlm6-2000a-3300-3p-4p-wlm6-series-thermal-magnetic-type-breaker-400v-690-detail-01-1.webp\" alt=\"WLM7HU-400-3300 3P solar type Molded Case Circuit Breaker 800V mccb 800VAC\/1000VAC\/1140VAC 400A 3 Poles detail image 1\" loading=\"lazy\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Rated Current : 400A Number Of Poles : 3P Rated Working Voltage : 800V<\/p>","protected":false},"featured_media":1951,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[96,106,172],"product_tag":[],"class_list":["post-1950","product","type-product","status-publish","has-post-thumbnail","product_cat-hu-voltage-mccb","product_cat-wlm7hu","product_cat-wlm7hu-all-product","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product\/1950","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/comments?post=1950"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/media\/1951"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/media?parent=1950"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_brand?post=1950"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_cat?post=1950"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/es\/wp-json\/wp\/v2\/product_tag?post=1950"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}